The relationship among the working temperature,pressure and current density of a Solid oxide fuel cell(SOFC)and its output power and efficiency are analyzed in the framework of a theoretical model able to provide,amon...The relationship among the working temperature,pressure and current density of a Solid oxide fuel cell(SOFC)and its output power and efficiency are analyzed in the framework of a theoretical model able to provide,among other things,the volt ampere characteristic curve.In particular,following the principle of temperature matching and cascade utilization,we consider a gas turbine(GT)and a LiBr absorption chiller to recycle the high-grade exhaust heat produced by the considered SOFC.This distributed total energy system is set up with the intent to meet typical needs of buildings for cooling,heating and power(CCHP).The total power generated by the considered SOFC and gas turbine is about 222 kW and the total power generation efficiency by low heat value of fuel(LHV)is 63.7%.In the CCHP system,the high temperature exhaust of GT is further used to drive LiBr absorption unit,which can produce about 34.8 kW cooling capacity or 84.5 kW of heat(the total energy utilization 78.03%).展开更多
冷热电联产(combined cooling, heating and power,CCHP)系统与微电网的结合有利于促进消纳可再生能源,为了提升CCHP型微电网的经济性、环保性和稳定性,提出了两阶段优化调度模型。离线优化阶段基于需求侧响应策略,建立了基于归一化法...冷热电联产(combined cooling, heating and power,CCHP)系统与微电网的结合有利于促进消纳可再生能源,为了提升CCHP型微电网的经济性、环保性和稳定性,提出了两阶段优化调度模型。离线优化阶段基于需求侧响应策略,建立了基于归一化法向约束法的多目标规划模型,并用熵权-TOPSIS法筛选最优结果。在线优化阶段建立了基于动态矩阵控制算法的有限时域优化模型,对离线优化结果进行跟踪优化和反馈校正,以降低不确定性因素的影响。最后,设计对比方案进行分析,验证了所提优化模型的有效性。展开更多
Although the Combined Cooing,Heating and Power System(hereinafter referred to as“CCHP”)improves the capacity utilization rate and energy utilization efficiency,single use of CCHP system cannot realize dynamic matchi...Although the Combined Cooing,Heating and Power System(hereinafter referred to as“CCHP”)improves the capacity utilization rate and energy utilization efficiency,single use of CCHP system cannot realize dynamic matching between supply and demand loads due to the unbalance features of the user’s cooling and heating loads.On the basis of user convenience and wide applicability of clean air energy,this paper tries to put forward a coupled CCHP system with combustion gas turbine and ASHP ordered power by heat,analyze trends of such parameters as gas consumption and power consumption of heat pump in line with adjustment of heating load proportion of combustion gas turbine,and optimize the system ratio in the method of annual costs and energy environmental benefit assessment.Based on the analysis of the hourly simulation and matching characteristics of the cold and hot load of the 100 thousand square meter building,it is found that the annual cost of the air source heat pump is low,but the energy and environmental benefits are poor.It will lead to 6.35%shortage of cooling load in summer.Combined with the evaluation method of primary energy consumption and zero carbon dioxide emission,the coupling system of CHHP and air source heat pump with 41%gas turbine load ratio is the best configuration.This system structure and optimization method can provide some reference for the development of CCHP coupling system.展开更多
This paper proposed a new type of combined cooling heating and power(CCHP)system,including the parabolic trough solar thermal(PTST)power generation and gas turbine power generation.The thermal energy storage subsystem...This paper proposed a new type of combined cooling heating and power(CCHP)system,including the parabolic trough solar thermal(PTST)power generation and gas turbine power generation.The thermal energy storage subsystem in the PTST unit provides both thermal energy and electrical energy.Based on the life cycle method,the configuration optimization under eight operation strategies is studied with the economy,energy,and environment indicators.The eight operation strategies include FEL,FEL-EC,FEL-TES,FEL-TES&EC,FTL,FTL-EC,FTL-TES,and FTL-TES&EC.The feasibility of each strategy is verified by taking a residential building cluster as an example.The indicators under the optimal configuration of each strategy are compared with that of the separate production(SP)system.The results showed that the PTST-CCHP system improves the environment and energy performance by changing the ratio of thermal energy and electric energy.The environment and energy indicators of FEL-TES&EC are superior to those of FTL-TES&EC in summer,and the results are just the opposite in winter.The initial annual investment of the PTST-CCHP system is higher than that of the SP system,but its economic performance is better than that of the SP system with the increase of life-cycle.展开更多
为提高冷热电联供(Combined Cooling Heating and Power,CCHP)型微网的综合运行效益,建立了以运行费用最小和二氧化碳排放量最小为目标的优化模型。针对源荷的不确定性,提出了基于误差场景整体生成与缩减的典型场景获得方法,并引入伪F-...为提高冷热电联供(Combined Cooling Heating and Power,CCHP)型微网的综合运行效益,建立了以运行费用最小和二氧化碳排放量最小为目标的优化模型。针对源荷的不确定性,提出了基于误差场景整体生成与缩减的典型场景获得方法,并引入伪F-统计(Pseudo F-statistics,PFS)指标用于确定最佳场景缩减数目。实例计算表明,与不考虑源荷不确定的确定性优化方法相比,所提方法在应对源荷的不确定性上具有较好效果,运行费用平均下降0.31%,二氧化碳排放量平均下降4.85%。此外,计算分析表明,应用PFS指标确定最佳聚类数目可以找到模型应对源荷不确定的能力与计算时间之间的平衡点,提高模型计算效率。展开更多
基金supported by the doctoral research initiation fund of Linyi University(Grant No.:204-40618051,Zhang,B.,http://www.lyu.edu.cn/).
文摘The relationship among the working temperature,pressure and current density of a Solid oxide fuel cell(SOFC)and its output power and efficiency are analyzed in the framework of a theoretical model able to provide,among other things,the volt ampere characteristic curve.In particular,following the principle of temperature matching and cascade utilization,we consider a gas turbine(GT)and a LiBr absorption chiller to recycle the high-grade exhaust heat produced by the considered SOFC.This distributed total energy system is set up with the intent to meet typical needs of buildings for cooling,heating and power(CCHP).The total power generated by the considered SOFC and gas turbine is about 222 kW and the total power generation efficiency by low heat value of fuel(LHV)is 63.7%.In the CCHP system,the high temperature exhaust of GT is further used to drive LiBr absorption unit,which can produce about 34.8 kW cooling capacity or 84.5 kW of heat(the total energy utilization 78.03%).
文摘冷热电联产(combined cooling, heating and power,CCHP)系统与微电网的结合有利于促进消纳可再生能源,为了提升CCHP型微电网的经济性、环保性和稳定性,提出了两阶段优化调度模型。离线优化阶段基于需求侧响应策略,建立了基于归一化法向约束法的多目标规划模型,并用熵权-TOPSIS法筛选最优结果。在线优化阶段建立了基于动态矩阵控制算法的有限时域优化模型,对离线优化结果进行跟踪优化和反馈校正,以降低不确定性因素的影响。最后,设计对比方案进行分析,验证了所提优化模型的有效性。
基金This research was funded by the research on rapid modeling methods for integrated energy systems,Grant No.SGTYHT/17-JS-204.
文摘Although the Combined Cooing,Heating and Power System(hereinafter referred to as“CCHP”)improves the capacity utilization rate and energy utilization efficiency,single use of CCHP system cannot realize dynamic matching between supply and demand loads due to the unbalance features of the user’s cooling and heating loads.On the basis of user convenience and wide applicability of clean air energy,this paper tries to put forward a coupled CCHP system with combustion gas turbine and ASHP ordered power by heat,analyze trends of such parameters as gas consumption and power consumption of heat pump in line with adjustment of heating load proportion of combustion gas turbine,and optimize the system ratio in the method of annual costs and energy environmental benefit assessment.Based on the analysis of the hourly simulation and matching characteristics of the cold and hot load of the 100 thousand square meter building,it is found that the annual cost of the air source heat pump is low,but the energy and environmental benefits are poor.It will lead to 6.35%shortage of cooling load in summer.Combined with the evaluation method of primary energy consumption and zero carbon dioxide emission,the coupling system of CHHP and air source heat pump with 41%gas turbine load ratio is the best configuration.This system structure and optimization method can provide some reference for the development of CCHP coupling system.
基金supported by the National Natural Science Foundation of China(Grant No.51667013)the Research on Scheduling Control Technology of Photothermal Power Generation of The Power System with High Proportion New Energy on The Supply End(Grant No.SGGSKY00FJJS1900273).
文摘This paper proposed a new type of combined cooling heating and power(CCHP)system,including the parabolic trough solar thermal(PTST)power generation and gas turbine power generation.The thermal energy storage subsystem in the PTST unit provides both thermal energy and electrical energy.Based on the life cycle method,the configuration optimization under eight operation strategies is studied with the economy,energy,and environment indicators.The eight operation strategies include FEL,FEL-EC,FEL-TES,FEL-TES&EC,FTL,FTL-EC,FTL-TES,and FTL-TES&EC.The feasibility of each strategy is verified by taking a residential building cluster as an example.The indicators under the optimal configuration of each strategy are compared with that of the separate production(SP)system.The results showed that the PTST-CCHP system improves the environment and energy performance by changing the ratio of thermal energy and electric energy.The environment and energy indicators of FEL-TES&EC are superior to those of FTL-TES&EC in summer,and the results are just the opposite in winter.The initial annual investment of the PTST-CCHP system is higher than that of the SP system,but its economic performance is better than that of the SP system with the increase of life-cycle.