Multiple loop heat pipe is a high-functional thermal transport device. This work was conducted to confirm the working performance of Multiple loop heat pipe under thermal vacuum ambience with the working fluid ammonia...Multiple loop heat pipe is a high-functional thermal transport device. This work was conducted to confirm the working performance of Multiple loop heat pipe under thermal vacuum ambience with the working fluid ammonia. Asmall multiple loop heat pipe with two evaporators and two ra- diators was designed and fabricated. Then thermal vacuum test was conducted. The heaters were fasten on both evaporators, both radiators, both compensation chambers. In the case that both evaporators were heated, the multiple loop heat pipe can transport 120/120 W for 1.5 m, in the case that only one evaporator was heated, evaporator 1 can transport 80 W for 1.5 m, while eva- porator 2 can transport 120 W for 1.5 m. Two flow regulators were installed near the confluence of liquid line to prevent uncondensed vapor penetrating into returning liquid when the tempera- ture difference exists between two radiators. In the case that the heat load at both evaporators were 40/40 W and one radiator was heated, the flow regulator1 can tolerate the 160 W of heat load which was supplied to radiator1 while the flow regulator2 can tolerate the 100 W of heat load which was supplied to radiator2. To demonstrate the multiple loop heat pipe’s startup behavior at lowheat load, each of the compensation chamber was preheated to change the initial distribution of liquid and vapor in the evaporator and compensation chamber, in the result, each evaporator can start up at 5W through preheating.展开更多
Vacuum Stability Test(VST)was used to determine the thermal behavior and kinetic parameters of 1,3,5,7-tetranitro-1,3,5,7-tetrazocine(HMX)and its mixture with hydroxyl-terminated polybutadiene(HTPB)as a binder coded a...Vacuum Stability Test(VST)was used to determine the thermal behavior and kinetic parameters of 1,3,5,7-tetranitro-1,3,5,7-tetrazocine(HMX)and its mixture with hydroxyl-terminated polybutadiene(HTPB)as a binder coded as HMX/HTPB.Model fitting and isoconversional method were applied to determine the kinetic parameters based on VST results.For comparison,non-isothermal thermogravimetry analysis data(TGA)was also used to calculate the kinetic parameters by using Kissinger,OFW(Ozawa,Flynn,and Wall)and KAS(Kissinger-Akahira-Sunose)methods.Advanced Kinetics and Technology Solution(AKTS)software was also used to determine the decomposition kinetics of the studied samples.Differential Scanning Calorimetry(DSC)was employed to determine the decomposition heat flow properties of the studied samples.Results show that the activation energies obtained using VST results is 360.1kJ/mol for pure HMX and 186.9kJ/mol for HMX/HTPB.The activation energies obtained by the three different methods using TGA results are in the range of 360-368kJ/mol for pure HMX and 190-206kJ/mol for HMX/HTPB.It is concluded that values of kinetic parameters obtained by VST are close to that obtained by the different techniques using TG/DTG results.The onset decomposition peak of HMX/HTPB is lower than that of HMX where the HTPB binder has negative effect on the thermal stability of HMX.The results of all the applied techniques prove that HMX/HTPB has lower activation energy and heat release than the pure HMX.HTPB polymeric matrix has negative effect on the kinetic parameters of HMX.展开更多
文摘Multiple loop heat pipe is a high-functional thermal transport device. This work was conducted to confirm the working performance of Multiple loop heat pipe under thermal vacuum ambience with the working fluid ammonia. Asmall multiple loop heat pipe with two evaporators and two ra- diators was designed and fabricated. Then thermal vacuum test was conducted. The heaters were fasten on both evaporators, both radiators, both compensation chambers. In the case that both evaporators were heated, the multiple loop heat pipe can transport 120/120 W for 1.5 m, in the case that only one evaporator was heated, evaporator 1 can transport 80 W for 1.5 m, while eva- porator 2 can transport 120 W for 1.5 m. Two flow regulators were installed near the confluence of liquid line to prevent uncondensed vapor penetrating into returning liquid when the tempera- ture difference exists between two radiators. In the case that the heat load at both evaporators were 40/40 W and one radiator was heated, the flow regulator1 can tolerate the 160 W of heat load which was supplied to radiator1 while the flow regulator2 can tolerate the 100 W of heat load which was supplied to radiator2. To demonstrate the multiple loop heat pipe’s startup behavior at lowheat load, each of the compensation chamber was preheated to change the initial distribution of liquid and vapor in the evaporator and compensation chamber, in the result, each evaporator can start up at 5W through preheating.
文摘Vacuum Stability Test(VST)was used to determine the thermal behavior and kinetic parameters of 1,3,5,7-tetranitro-1,3,5,7-tetrazocine(HMX)and its mixture with hydroxyl-terminated polybutadiene(HTPB)as a binder coded as HMX/HTPB.Model fitting and isoconversional method were applied to determine the kinetic parameters based on VST results.For comparison,non-isothermal thermogravimetry analysis data(TGA)was also used to calculate the kinetic parameters by using Kissinger,OFW(Ozawa,Flynn,and Wall)and KAS(Kissinger-Akahira-Sunose)methods.Advanced Kinetics and Technology Solution(AKTS)software was also used to determine the decomposition kinetics of the studied samples.Differential Scanning Calorimetry(DSC)was employed to determine the decomposition heat flow properties of the studied samples.Results show that the activation energies obtained using VST results is 360.1kJ/mol for pure HMX and 186.9kJ/mol for HMX/HTPB.The activation energies obtained by the three different methods using TGA results are in the range of 360-368kJ/mol for pure HMX and 190-206kJ/mol for HMX/HTPB.It is concluded that values of kinetic parameters obtained by VST are close to that obtained by the different techniques using TG/DTG results.The onset decomposition peak of HMX/HTPB is lower than that of HMX where the HTPB binder has negative effect on the thermal stability of HMX.The results of all the applied techniques prove that HMX/HTPB has lower activation energy and heat release than the pure HMX.HTPB polymeric matrix has negative effect on the kinetic parameters of HMX.