By taking a 2.3 MW double-fed asynchronous generator as an example,a new method for fast simulation analysis of ventilation cooling system inside generator is proposed based on the one-dimensional simulation software ...By taking a 2.3 MW double-fed asynchronous generator as an example,a new method for fast simulation analysis of ventilation cooling system inside generator is proposed based on the one-dimensional simulation software FLOWMASTER.The thermal-fluid coupling simulation model of ventilation cooling system inside generator is established.Under the stable running state of the generator,the flow velocity distribution and temperature rise of the key parts of the generator are analyzed.The results prove that the ventilation structure design of the generator meets the temperature rise limit.The simulation results are compared with the theoretical calculation results and the experimental results,which verify the correctness of the thermal-fluid coupling simulation method proposed in this paper.展开更多
Modeling and simulation of thermal-fluid systems are very important in industrial numerical simulation and play key roles in their design and control. In this paper, the modeling and simplification method of one-dimen...Modeling and simulation of thermal-fluid systems are very important in industrial numerical simulation and play key roles in their design and control. In this paper, the modeling and simplification method of one-dimensional thermal-fluid network with variable-property are presented, including matrix representation of the network, simplification algorithm for series/parallel connection based on matrix operation and generation of flow equations based on system topology. This simplification is suitable for the simulation of thermal-fluid systems with arbitrary topological structure. The method to treat reflux during iteration is proposed. The outstanding features of the simplification algorithm are the significant reduction in the thermal-fluid network and therefore the number of the related governing equations, as well as the computation burden. The example in this paper shows that the number of the governing equations for flow is reduced by about 45% and the calculation time of flow calculation is reduced by an average of 32% after the simplification.展开更多
Gas foil bearing faces severe and complex thermal-fluid–solid coupling issues when in ultra-high speed and miniaturized impeller machineries.In this study,a Thermo-Elasto-Hydrodynamic(TEHD)analysis of a specific mult...Gas foil bearing faces severe and complex thermal-fluid–solid coupling issues when in ultra-high speed and miniaturized impeller machineries.In this study,a Thermo-Elasto-Hydrodynamic(TEHD)analysis of a specific multi-layer gas foil thrust bearing on the continuous loading process within a steady rotational speed is numerically investigated by a three-dimensional thermal-fluid–solid coupling method.Results indicate that the multi-layer foil exhibits nonlinear overall stiffness,with the thrust bottom foil serving as the primary elastic deformation structure,while the thrust top foil maintains a well-defined aerodynamic shape during a loading process,which helps reduce frictional damage and achieve an adequate loading capacity.For low loads,the fluctuation of the gas film is extremely sensitive,and it weakens dramatically as the load increases.The viscous heating and friction torque exhibit a linear relationship with an increasing bearing load after a rapid growth.Depending on the exact stacking sequence and contact position of the multi-layer gas foil,the overlapping configuration allows for efficient transfer of viscous-shearing heat accumulated at the smallest air film through thermal conduction while providing elastic support.Due to the strong inhomogeneity of the viscous heat under varying loads,the temperature distribution on the top foil surface shows pronounced variations,while the difference between the peak and average temperatures of the thrust plate and top foil surfaces widens substantially with an increasing load.展开更多
基金ACKNOWLEDGMENTS The work was supported by the National Nature Science Foundation of China (Nos.11161002 and 41001320), Natural Science Foundation of Jiangxi province (No.20114BAB201016). Thanks for the useful advices of the editors and the reviewers.
文摘By taking a 2.3 MW double-fed asynchronous generator as an example,a new method for fast simulation analysis of ventilation cooling system inside generator is proposed based on the one-dimensional simulation software FLOWMASTER.The thermal-fluid coupling simulation model of ventilation cooling system inside generator is established.Under the stable running state of the generator,the flow velocity distribution and temperature rise of the key parts of the generator are analyzed.The results prove that the ventilation structure design of the generator meets the temperature rise limit.The simulation results are compared with the theoretical calculation results and the experimental results,which verify the correctness of the thermal-fluid coupling simulation method proposed in this paper.
文摘Modeling and simulation of thermal-fluid systems are very important in industrial numerical simulation and play key roles in their design and control. In this paper, the modeling and simplification method of one-dimensional thermal-fluid network with variable-property are presented, including matrix representation of the network, simplification algorithm for series/parallel connection based on matrix operation and generation of flow equations based on system topology. This simplification is suitable for the simulation of thermal-fluid systems with arbitrary topological structure. The method to treat reflux during iteration is proposed. The outstanding features of the simplification algorithm are the significant reduction in the thermal-fluid network and therefore the number of the related governing equations, as well as the computation burden. The example in this paper shows that the number of the governing equations for flow is reduced by about 45% and the calculation time of flow calculation is reduced by an average of 32% after the simplification.
基金the financial supports provided by the Natural Science Fund of Jiangsu Province,China(No.BK20200448)the Postdoctoral Science Foundation of China(No.2020TQ0143)。
文摘Gas foil bearing faces severe and complex thermal-fluid–solid coupling issues when in ultra-high speed and miniaturized impeller machineries.In this study,a Thermo-Elasto-Hydrodynamic(TEHD)analysis of a specific multi-layer gas foil thrust bearing on the continuous loading process within a steady rotational speed is numerically investigated by a three-dimensional thermal-fluid–solid coupling method.Results indicate that the multi-layer foil exhibits nonlinear overall stiffness,with the thrust bottom foil serving as the primary elastic deformation structure,while the thrust top foil maintains a well-defined aerodynamic shape during a loading process,which helps reduce frictional damage and achieve an adequate loading capacity.For low loads,the fluctuation of the gas film is extremely sensitive,and it weakens dramatically as the load increases.The viscous heating and friction torque exhibit a linear relationship with an increasing bearing load after a rapid growth.Depending on the exact stacking sequence and contact position of the multi-layer gas foil,the overlapping configuration allows for efficient transfer of viscous-shearing heat accumulated at the smallest air film through thermal conduction while providing elastic support.Due to the strong inhomogeneity of the viscous heat under varying loads,the temperature distribution on the top foil surface shows pronounced variations,while the difference between the peak and average temperatures of the thrust plate and top foil surfaces widens substantially with an increasing load.