期刊文献+
共找到159篇文章
< 1 2 8 >
每页显示 20 50 100
GaN HEMT及GaN栅驱动电路在DToF激光雷达中的应用 被引量:2
1
作者 秦尧 明鑫 +2 位作者 叶自凯 庄春旺 张波 《电子与封装》 2023年第1期22-29,共8页
DToF(Direct Time-of-Flight)激光雷达通过直接测量激光的飞行时间完成距离测量和地图成像,应用于自动驾驶的DToF激光雷达需要具备更高的分辨率和更宽的检测范围。GaN高电子迁移率晶体管(HEMT)相对于传统Si基功率MOSFET的优异特性使其... DToF(Direct Time-of-Flight)激光雷达通过直接测量激光的飞行时间完成距离测量和地图成像,应用于自动驾驶的DToF激光雷达需要具备更高的分辨率和更宽的检测范围。GaN高电子迁移率晶体管(HEMT)相对于传统Si基功率MOSFET的优异特性使其非常适合应用于自动驾驶中的DToF激光雷达,而GaN HEMT性能的发挥依赖于高速、高驱动能力和高可靠性的GaN栅驱动电路。针对应用于自动驾驶的DToF激光雷达系统,从系统电路到核心元器件,分析了激光二极管驱动电路面临的设计挑战、GaN HEMT的优势以及GaN栅驱动电路面临的设计挑战,并介绍了适合该应用的GaN栅驱动电路。 展开更多
关键词 dtof激光雷达 激光二极管驱动电路 GaN HEMT GaN栅驱动电路
下载PDF
Direct measurement of an energy-dependent single-event-upset cross-section with time-of-flight method at CSNS 被引量:1
2
作者 裴标 谭志新 +2 位作者 贺永宁 赵小龙 樊瑞睿 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第2期11-19,共9页
To predict the soft error rate for applications, it is essential to study the energy dependence of the single-event-upset(SEU) cross-section. In this work, we present a direct measurement of the SEU cross-section with... To predict the soft error rate for applications, it is essential to study the energy dependence of the single-event-upset(SEU) cross-section. In this work, we present a direct measurement of the SEU cross-section with the Back-n white neutron source at the China Spallation Neutron Source. The measured cross section is consistent with the soft error data from the manufacturer and the result suggests that the threshold energy of the SEU is about 0.5 Me V, which confirms the statement in Iwashita’s report that the threshold energy for neutron soft error is much below that of the(n, α) cross-section of silicon.In addition, an index of the effective neutron energy is suggested to characterize the similarity between a spallation neutron beam and the standard atmospheric neutron environment. 展开更多
关键词 static random-access memory soft error rate neutron SEU cross-section time-of-flight
下载PDF
Time-of-Flight透散射介质成像技术综述 被引量:1
3
作者 王霞 张艺馨 +1 位作者 赵雨薇 金伟其 《红外与激光工程》 EI CSCD 北大核心 2023年第2期370-381,共12页
Time-of-Flight (ToF)成像是利用光在目标和相机之间的飞行时间来获取场景的深度信息,具有体积小、成本低、实时成像等优势。在散射环境中,由于散射介质对光的散射作用,ToF成像受到多径干扰的影响,深度测量误差较大,限制了ToF相机在散... Time-of-Flight (ToF)成像是利用光在目标和相机之间的飞行时间来获取场景的深度信息,具有体积小、成本低、实时成像等优势。在散射环境中,由于散射介质对光的散射作用,ToF成像受到多径干扰的影响,深度测量误差较大,限制了ToF相机在散射场景中的应用。ToF透散射介质成像技术是校正因散射光引起的多径干扰效应,从传感器接收到的混叠信号中分离出目标分量,实现散射场景中的深度信息恢复,其在雾天自动驾驶、水下勘测、生物医学等领域具有广阔的应用前景。依据ToF成像系统的不同,详细介绍了PL-ToF和CW-ToF成像的基本原理,阐述和分析了散射场景中ToF稳态成像和瞬态成像的机理和特点,分别回顾和总结了ToF稳态成像和瞬态成像的透散射介质成像研究现状,并介绍了ToF透散射介质成像的应用前景,最后依据现有ToF透散射介质成像技术的优缺点,对未来发展趋势进行了展望。 展开更多
关键词 成像系统 透散射介质成像 time-of-flight相机 稳态成像 瞬态成像
下载PDF
A 128×128 SPAD LiDAR sensor with column-parallel 25 ps resolution TA-ADCs 被引量:1
4
作者 Na Tian Zhe Wang +6 位作者 Kai Ma Xu Yang Nan Qi Jian Liu Nanjian Wu Runjiang Dou Liyuan Liu 《Journal of Semiconductors》 EI CAS CSCD 2024年第8期34-40,共7页
This paper presents a design of single photon avalanche diode(SPAD)light detection and ranging(LiDAR)sensor with 128×128 pixels and 128 column-parallel time-to-analog-merged-analog-to-digital converts(TA-ADCs).Un... This paper presents a design of single photon avalanche diode(SPAD)light detection and ranging(LiDAR)sensor with 128×128 pixels and 128 column-parallel time-to-analog-merged-analog-to-digital converts(TA-ADCs).Unlike the conventional TAC-based SPAD LiDAR sensor,in which the TAC and ADC are separately implemented,we propose to merge the TAC and ADC by sharing their capacitors,thus avoiding the analog readout noise of TAC’s output buffer,improving the conversion rate,and reducing chip area.The reverse start-stop logic is employed to reduce the power of the TA-ADC.Fabricated in a 180 nm CMOS process,our prototype sensor exhibits a timing resolution of 25 ps,a DNL of+0.30/−0.77 LSB,an INL of+1.41/−2.20 LSB,and a total power consumption of 190 mW.A flash LiDAR system based on this sensor demonstrates the function of 2D/3D imaging with 128×128 resolution,25 kHz inter-frame rate,and sub-centimeter ranging precision. 展开更多
关键词 3D imaging CMOS imagers direct time-of-flight(dtof) time-to-analog converter(TAC)
下载PDF
Measurement of the neutron-induced total cross sections of ^(nat)Pb from 0.3 eV to 20 MeV on the Back-n at CSNS
5
作者 Jie-Ming Xue Song Feng +14 位作者 Yong-Hao Chen Han Yi Min Xiao Pin-Jing Cheng Xin-Xiang Li Rong Liu Yi-Wei Yang Zi-Jie Han Da-Jun Zhao Hao-Qiang Wang Bao-Qian Li Ji-Rong Zhao Lei-Xun Tang Wen Luo Bo Zheng 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第2期85-93,共9页
The neutron-induced total cross sections of natural lead have been measured in a wide energy range(0.3 eV-20 MeV)on the back-streaming white neutron beamline(Back-n)at the China Spallation Neutron Source.Neutron energ... The neutron-induced total cross sections of natural lead have been measured in a wide energy range(0.3 eV-20 MeV)on the back-streaming white neutron beamline(Back-n)at the China Spallation Neutron Source.Neutron energy was determined by the neutron total cross-section spectrometer using the time-of-flight technique.A fast multi-cell fission chamber was used as the neutron detector,and a 10-mm-thick high-purity natural lead sample was employed for the neutron transmission measurements.The on-beam background was determined using Co,In,Ag,and Cd filters.The excitation function of ^(nat)Pb(n,tot)reaction below 20 MeV was calculated using the TALYS-1.96 nuclear-reaction modeling program.The present results were compared with previous results,the evaluated data available in the five major evaluated nuclear data libraries(i.e.,ENDF/B-VIII.0,JEFF-3.3,JENDL-5,CENDL-3.2,and BROND-3.1),and the theoretical calculation curve.Good agreement was found between the new results and those of previous experiments and with the theoretical curves in the corresponding region.This measurement obtained the neutron total cross section of natural lead with good accuracy over a wide energy range and added experimental data in the resonance energy range.This provides more reliable experimental data for nuclear engineering design and nuclear data evaluation of lead. 展开更多
关键词 Neutron-induced total cross section Natural lead time-of-flight TALYS-1.96 CSNS Back-n white neutron beamline
下载PDF
便捷式家用投影仪梯形几何校正系统的设计
6
作者 陈健锋 洪坤 +1 位作者 郭焰芳 张伟 《现代信息科技》 2024年第9期47-52,共6页
针对家用投影仪没有正对成像平面而引发梯形畸变成像问题,设计一款基于DToF测距传感器模块、三轴加速度传感器模块和图像变换的便捷式梯形几何校正系统,实现无须人工干预的梯形畸变画面自动修正。同时引入基于顶点预标定的最大内接矩形... 针对家用投影仪没有正对成像平面而引发梯形畸变成像问题,设计一款基于DToF测距传感器模块、三轴加速度传感器模块和图像变换的便捷式梯形几何校正系统,实现无须人工干预的梯形畸变画面自动修正。同时引入基于顶点预标定的最大内接矩形算法,辅助畸变校正画面实现面积最大化和长宽比例不失真。实验结果表明,该系统能以低廉的硬件成本、便捷的操作方式完成投影仪在复杂空间姿态下梯形畸变成像的修正工作,增强观影舒适度。 展开更多
关键词 家用投影仪 梯形几何校正 直接飞行时间测距传感器 三轴加速度传感器 图像变换
下载PDF
A Reflectron Time-of-Flight Mass Spectrometer with a Nano-Electrospray Ionization Source for Study of Metal Cluster Compounds
7
作者 吴小虎 谢华 +3 位作者 刘志凌 苏海峰 林水潮 唐紫超 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2016年第4期401-406,I0001,共7页
An experiment facility has been set up for the study of metal cluster compounds in our laboratory, which consists of a nano-electrospray ionization source, an ion transmission and focus system, and a reflectron time-o... An experiment facility has been set up for the study of metal cluster compounds in our laboratory, which consists of a nano-electrospray ionization source, an ion transmission and focus system, and a reflectron time-of-fight mass spectrometer. Taking advantage of the nano-electrospray ionization source, polyvalent ions are usually produced in the "ionization" process and the obtained mass resolution of the equipment is over 8000. The molecular ion peaks of metal cluster compounds [Au20(PPhpy2)10Cl2](SbF6)4, where PPhpy2=bis(2- pyridyl)phenylphosphine, and [AuaAg2(C)L6](BF4)4, where L=2-(diphenylphosphino)-5- methylpyridine, are distinguished in the respective mass spectrum, accompanied by some fragment ion peaks. In addition, the mass-to-charge ratios of the parent ions are determi- nated. Preliminary results suggest that the device is a powerful tool for the study of metal cluster compounds. It turns out that the information obtained by the instrumentation serves as an essential supplement to single crystal X-ray diffraction for structure characterization of metal cluster compounds. 展开更多
关键词 Nano-electrospray ionization source Ion transmission and focus system Reflectron time-of-flight mass spectrometer Metal cluster compounds Single crystal X-ray diffraction
下载PDF
Automatic Feature Point Detection and Tracking of Human Actions in Time-of-flight Videos 被引量:8
8
作者 Xiaohui Yuan Longbo Kong +1 位作者 Dengchao Feng Zhenchun Wei 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2017年第4期677-685,共9页
Detecting feature points on the human body in video frames is a key step for tracking human movements. There have been methods developed that leverage models of human pose and classification of pixels of the body imag... Detecting feature points on the human body in video frames is a key step for tracking human movements. There have been methods developed that leverage models of human pose and classification of pixels of the body image. Yet, occlusion and robustness are still open challenges. In this paper, we present an automatic, model-free feature point detection and action tracking method using a time-of-flight camera. Our method automatically detects feature points for movement abstraction. To overcome errors caused by miss-detection and occlusion, a refinement method is devised that uses the trajectory of the feature points to correct the erroneous detections. Experiments were conducted using videos acquired with a Microsoft Kinect camera and a publicly available video set and comparisons were conducted with the state-of-the-art methods. The results demonstrated that our proposed method delivered improved and reliable performance with an average accuracy in the range of 90 %.The trajectorybased refinement also demonstrated satisfactory effectiveness that recovers the detection with a success rate of 93.7 %. Our method processed a frame in an average time of 71.1 ms. 展开更多
关键词 Feature point human pose detection joint detection time-of-flight(ToF) videos
下载PDF
Offline two-dimensional liquid chromatography coupled with ion mobility-quadrupole time-of-flight mass spectrometry enabling fourdimensional separation and characterization of the multicomponents from white ginseng and red ginseng 被引量:9
9
作者 Tiantian Zuo Chunxia Zhang +7 位作者 Weiwei Li Hongda Wang Ying Hu Wenzhi Yang Li Jia Xiaoyan Wang Xiumei Gao Dean Guo 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2020年第6期597-609,共13页
Inherent complexity of plant metabolites necessitates the use of multi-dimensional information to accomplish comprehensive profiling and confirmative identification.A dimension-enhanced strategy,by offline two-dimensi... Inherent complexity of plant metabolites necessitates the use of multi-dimensional information to accomplish comprehensive profiling and confirmative identification.A dimension-enhanced strategy,by offline two-dimensional liquid chromatography/ion mobility-quadrupole time-of-flight mass spectrometry(2 D-LC/IM-QTOF-MS)enabling four-dimensional separations(2 D-LC,IM,and MS),is proposed.In combination with in-house database-driven automated peak annotation,this strategy was utilized to characterize ginsenosides simultaneously from white ginseng(WG)and red ginseng(RG).An offline 2 DLC system configuring an Xbridge Amide column and an HSS T3 column showed orthogonality 0.76 in the resolution of ginsenosides.Ginsenoside analysis was performed by data-independent high-definition MSE(HDMSE)in the negative ESI mode on a Vion?IMS-QTOF hybrid high-resolution mass spectrometer,which could better resolve ginsenosides than MSEand directly give the CCS information.An in-house ginsenoside database recording 504 known ginsenosides and 58 reference compounds,was established to assist the identification of ginsenosides.Streamlined workflows,by applying UNIFI?to automatedly annotate the HDMSEdata,were proposed.We could separate and characterize 323 ginsenosides(including 286 from WG and 306 from RG),and 125 thereof may have not been isolated from the Panax genus.The established 2 D-LC/IM-QTOF-HDMSEapproach could also act as a magnifier to probe differentiated components between WG and RG.Compared with conventional approaches,this dimensionenhanced strategy could better resolve coeluting herbal components and more efficiently,more reliably identify the multicomponents,which,we believe,offers more possibilities for the systematic exposure and confirmative identification of plant metabolites. 展开更多
关键词 Dimension-enhanced strategy Multicomponent characterization GINSENOSIDE Offline two-dimensional liquid chromatography Ion mobility-quadrupole time-of-flight mass spectrometry In-house database
下载PDF
Modification of Reflectron Time-of-Flight Mass Spectrometer for Photodissociation of Mass-Selected Cluster lons 被引量:3
10
作者 Yu-chao Zhao Zeng-guang Zhang +2 位作者 Jin-yun Yuan Hong-guang Xu Wei-jun Zheng 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2009年第6期655-662,J0002,共9页
We introduce a modification of reflectron time-of-flight mass spectrometer for laser photodissociation of mass-selected ions. In our apparatus, the ions of interests were selected by a mass gate near the first space f... We introduce a modification of reflectron time-of-flight mass spectrometer for laser photodissociation of mass-selected ions. In our apparatus, the ions of interests were selected by a mass gate near the first space focus point and decelerated right after the mass gate, were then crossed by a laser beam for dissociation. The daughter ions and surviving parent ions were re-accelerated and analyzed by the reflectron time-of-flight mass spectrometer. Compared to the designs reported by other research groups, our selection-deceleration-dissociation-reacceleration approach has better daughter-parent-ions-separation, easier laser timing, and better overlapping between the ion beam and laser beam. We also conducted detailed cal- culations on the parent ion and daughter ion flight times, and provided a simplified formula for the calibration of daughter ion mass. 展开更多
关键词 Reflectron time-of-flight mass spectrometer PHOTODISSOCIATION Mass-selection CLUSTER
下载PDF
Liquid chromatography coupled with time-of-flight and ion trap mass spectrometry for qualitative analysis of herbal medicines 被引量:11
11
作者 Xiao-Fei Chen Hai-Tang Wu +2 位作者 Guang-Guo Tan Zhen-Yu Zhu Yi-Feng Chai 《Journal of Pharmaceutical Analysis》 SCIE CAS 2011年第4期235-245,共11页
With the expansion of herbal medicine (HM) market, the issue on how to apply up-to- date analytical tools on qualitative analysis of HMs to assure their quality, safety and efficacy has been arousing great attention... With the expansion of herbal medicine (HM) market, the issue on how to apply up-to- date analytical tools on qualitative analysis of HMs to assure their quality, safety and efficacy has been arousing great attention. Due to its inherent characteristics of accurate mass measurements and multiple stages analysis, the integrated strategy of liquid chromatography (LC) coupled with time-of-flight mass spectrometry (TOF-MS) and ion trap mass spectrometry (IT-MS) is well-suited to be performed as qualitative analysis tool in this field. The purpose of this review is to provide an overview on the potential of this integrated strategy, including the review of general features of LC-IT-MS and LC-TOF-MS, the advantages of their combination, the common procedures for structure elucidation, the potential of LC-hybrid-IT-TOF/MS and also the summary and discussion of the applications of the integrated strategy for HM qualitative analysis (2006-2011). The advantages and future developments of LC coupled with IT and TOF-MS are highlighted. 展开更多
关键词 High-performanceliquid chromatography(HPLC) time-of-flight massspectrometry(TOF-MS) Ion trap massspectrometry (IT-MS) Herbal medicine (HM)
下载PDF
Three-dimensional time-of-flight magnetic resonance angiography combined with high resolution T2-weighted imaging in preoperative evaluation of microvascular decompression 被引量:1
12
作者 Chen Liang Ling Yang +2 位作者 Bin-Bin Zhang Shi-Wen Guo Rui-Chun Li 《World Journal of Clinical Cases》 SCIE 2022年第34期12594-12604,共11页
BACKGROUND Neurovascular compression(NVC) is the main cause of primary trigeminal neuralgia(TN) and hemifacial spasm(HFS). Microvascular decompression(MVD) is an effective surgical method for the treatment of TN and H... BACKGROUND Neurovascular compression(NVC) is the main cause of primary trigeminal neuralgia(TN) and hemifacial spasm(HFS). Microvascular decompression(MVD) is an effective surgical method for the treatment of TN and HFS caused by NVC. The judgement of NVC is a critical step in the preoperative evaluation of MVD, which is related to the effect of MVD treatment. Magnetic resonance imaging(MRI) technology has been used to detect NVC prior to MVD for several years. Among many MRI sequences, three-dimensional time-of-flight magnetic resonance angiography(3D TOF MRA) is the most widely used. However, 3D TOF MRA has some shortcomings in detecting NVC. Therefore, 3D TOF MRA combined with high resolution T2-weighted imaging(HR T2WI) is considered to be a more effective method to detect NVC.AIM To determine the value of 3D TOF MRA combined with HR T2WI in the judgment of NVC, and thus to assess its value in the preoperative evaluation of MVD.METHODS Related studies published from inception to September 2022 based on PubMed, Embase, Web of Science, and the Cochrane Library were retrieved. Studies that investigated 3D TOF MRA combined with HR T2WI to judge NVC in patients with TN or HFS were included according to the inclusion criteria. Studies without complete data or not relevant to the research topics were excluded. The Quality Assessment of Diagnostic Accuracy Studies checklist was used to assess the quality of included studies. The publication bias of the included literature was examined by Deeks’ test. An exact binomial rendition of the bivariate mixed-effects regression model was used to synthesize data. Data analysis was performed using the MIDAS module of statistical software Stata 16.0. Two independent investigators extracted patient and study characteristics, and discrepancies were resolved by consensus. Individual and pooled sensitivities and specificities were calculated. The I_(2) statistic and Q test were used to test heterogeneity. The study was registered on the website of PROSERO(registration No. CRD42022357158).RESULTS Our search identified 595 articles, of which 12(including 855 patients) fulfilled the inclusion criteria. Bivariate analysis showed that the pooled sensitivity and specificity of 3D TOF MRA combined with HR T2WI for detecting NVC were 0.96 [95% confidence interval(CI): 0.92-0.98] and 0.92(95%CI: 0.74-0.98), respectively. The pooled positive likelihood ratio was 12.4(95%CI: 3.2-47.8), pooled negative likelihood ratio was 0.04(95%CI: 0.02-0.09), and pooled diagnostic odds ratio was 283(95%CI: 50-1620). The area under the receiver operating characteristic curve was 0.98(95%CI: 0.97-0.99). The studies showed no substantial heterogeneity(I2 = 0, Q = 0.001 P = 0.50).CONCLUSION Our results suggest that 3D TOF MRA combined with HR T2WI has excellent sensitivity and specificity for judging NVC in patients with TN or HFS. This method can be used as an effective tool for preoperative evaluation of MVD. 展开更多
关键词 Three-dimensional time-of-flight magnetic resonance angiography High resolution T2 weighted imaging Neurovascular compression Microvascular decompression META-ANALYSIS
下载PDF
Dimension-Enhanced Ultra-High Performance Liquid Chromatography/Ion Mobility-Quadrupole Time-of-Flight Mass Spectrometry Combined with Intelligent Peak Annotation for the Rapid Characterization of the Multiple Components from Seeds of Descurainia sophia 被引量:1
13
作者 Simiao Wang Xue Li +7 位作者 Boxue Chen Shitong Li Jiali Wang Jing Wang Mingshuo Yang Xiaoyan Xu Hongda Wang Wenzhi Yang 《Phyton-International Journal of Experimental Botany》 SCIE 2022年第3期541-567,共27页
The complex composition of herbal metabolites necessitates the development of powerful analytical techniques aimed to identify the bioactive components.The seeds of Descurainia sophia(SDS)are utilized in China as a co... The complex composition of herbal metabolites necessitates the development of powerful analytical techniques aimed to identify the bioactive components.The seeds of Descurainia sophia(SDS)are utilized in China as a cough and asthma relieving agent.Herein,a dimension-enhanced integral approach,by combining ultra-high performance liquid chromatography/ion mobility-quadrupole time-of-flight mass spectrometry(UHPLC/IMQTOF-MS)and intelligent peak annotation,was developed to rapidly characterize the multicomponents from SDS.Good chromatographic separation was achieved within 38 min on a UPLC CSH C18(2.1×100 mm,1.7μm)column which was eluted by 0.1%formic acid in water(water phase)and acetonitrile(organic phase).Collision-induced dissociation-MS^(2)data were acquired by the data-independent high-definition MS^(E)(HDMS^(E))in both the negative and positive electrospray ionization modes.A major components knockout strategy was applied to improve the characterization of those minor ingredients by enhancing the injection volume.Moreover,a self-built chemistry library was established,which could be matched by the UNIFI software enabling automatic peak annotation of the obtained HDMS^(E)data.As a result of applying the intelligent peak annotation workflows and further confirmation process,a total of 53 compounds were identified or tentatively characterized from the SDS,including 29 flavonoids,one uridine derivative,four glucosides,one lignin,one phenolic compound,and 17 others.Notably,four-dimensional information related to the structure(e.g.,retention time,collision cross section,MS^(1)and MS^(2)data)was obtained for each component by the developed integral approach,and the results would greatly benefit the quality control of SDS. 展开更多
关键词 Descurainia sophia multicomponent characterization ultra-high performance liquid chromatography ion mobility/quadrupole time-of-flight mass spectrometry high-definition MS^(E) flavonoid
下载PDF
Single-Frequency Matching Pursuits Based Time-of-Flight Measurement in Viscoacoustic Medium
14
作者 沈祥立 沈毅 +2 位作者 冯乃章 金晶 孙明健 《Transactions of Tianjin University》 EI CAS 2011年第5期356-361,共6页
Broadband ultrasound signals will produce distortion in viscoacoustic medium, which may influence the accuracy of time-of-flight (TOF) measurement. Under the condition of single-frequency acoustic source, the wave pro... Broadband ultrasound signals will produce distortion in viscoacoustic medium, which may influence the accuracy of time-of-flight (TOF) measurement. Under the condition of single-frequency acoustic source, the wave propagation process in viscoacoustic medium was analyzed and an approximate solution of the wave propagation was given. Instances of broadband ultrasound were analyzed and simulated based on the single-frequency results. A single-frequency matching pursuits (SFMP) algorithm was then introduced to solve the waveform distortion problem. Time-frequency decomposition was applied to extracting the single-frequency compositions from broadband ultrasound signals, and then these compositions were sent to the matching pursuits (MP) algorithm for calculating the TOF parameters. Compared with the broadband signals, the shapes of extracted single-frequency signals change more slightly as distance and attenuation coefficient increase. The residuals of SFMP were far less than those of MP algorithm. Experimental results show that the SFMP algorithm is able to eliminate waveform distortion of broadband ultrasound in viscoacoustic medium, which helps improve the accuracy of TOF measurement. 展开更多
关键词 matching pursuit SINGLE-FREQUENCY time-of-flight ultrasound absorption VISCOSITY
下载PDF
New Fragmentation Pathways for Cephalosporins by Electrospray Ionization Quadrupole Time-of-flight Mass Spectrometry
15
作者 WANGYing-wu GUJing-kai +2 位作者 J.PaulFawcett ZHONGDa-fang ZHOUHui 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2005年第3期376-379,共4页
关键词 CEPHALOSPORINS time-of-flight mass spectrometry Fragmentation pathway
下载PDF
Studies on Fragmentation Regularity of 5-Methoxycarbonyl- 4-substituted-6-methyl-3,4-dihydropyrimidin-2(1H)-ones by Time-of-flight Mass Spectrometry
16
作者 LIQian-rong SALEHIHojatollah +1 位作者 YINHao GUOQing-xiang 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2004年第6期729-733,共5页
The electron impact time-of-flight(TOF) mass spectra of the title compounds were studied to establish their fragmentation processes. With the high resolution of the TOF instrument, the exact mass for each fragment was... The electron impact time-of-flight(TOF) mass spectra of the title compounds were studied to establish their fragmentation processes. With the high resolution of the TOF instrument, the exact mass for each fragment was determined. These data were used to infer the molecular formulas and the elemental compositions for all the molecular ions and fragments through software interpretation. By further applying the fragmentation regularity, the majority of ions were fully assigned. The main fragmentation pathways of the title compounds include the formation of molecular ions by the loss of R 1 groups in the 4-position and the ester groups in the 5-position. The formed ion can be further fragmented by the elimination of MeOH. 展开更多
关键词 3 4-Dihydropyrimidinone time-of-flight mass spectrometry Electron impact
下载PDF
Analytic time-of-flight positron emission tomography reconstruction: threedimensional case
17
作者 Gengsheng L.Zeng Ya Li Qiu Huang 《Visual Computing for Industry,Biomedicine,and Art》 2020年第1期39-52,共14页
In a positron emission tomography(PET)scanner,the time-of-flight(TOF)information gives us rough event position along the line-of-response(LOR).Using the TOF information for PET image reconstruction is able to reduce i... In a positron emission tomography(PET)scanner,the time-of-flight(TOF)information gives us rough event position along the line-of-response(LOR).Using the TOF information for PET image reconstruction is able to reduce image noise.The state-of-the-art TOF PET image reconstruction uses iterative algorithms.This study introduces an analytic TOF PET algorithm that focuses on three-dimensional(3D)reconstruction.The proposed algorithm is in the form of backprojection filtering,in which the backprojection is performed first by using a time-resolution profile function,and then a 3D filter is applied to the backprojected image.For the list-mode data,the backprojection is carried out in the event-by-event fashion,and the timing resolution determined weighting function is used along the projection LOR.Computer simulations are carried out to verify the feasibility of the proposed algorithm. 展开更多
关键词 Positron emission tomography time-of-flight Analytic reconstruction
下载PDF
The Development of Time-of-flight Mass Spectrometry( TOF-MS) and Its Applications in Screening Food Hazard Factors
18
作者 Lei WANG Lixue DONG +4 位作者 Yi LI Huihui CAO Yanhua YAN Ruihuan DU Aijun LI 《Agricultural Biotechnology》 CAS 2020年第2期101-104,共4页
The time-of-flight mass spectrometry(TOF-MS),one of the mass spectrometry techniques,has been widely applied in the field of rapid screening of food hazard factors as a superior analysis technique because of its wide ... The time-of-flight mass spectrometry(TOF-MS),one of the mass spectrometry techniques,has been widely applied in the field of rapid screening of food hazard factors as a superior analysis technique because of its wide mass range,high resolution and mass measurement accuracy,high sensitivity and high analysis speed.In this paper,research progresses of TOF-MS on the detection of food additives,food contaminants and residues,illegal additives,pesticide residues,veterinary drug residues and mycotoxin were reviewed,and its probable approaching applications were prospected. 展开更多
关键词 time-of-flight mass SPECTROMETRY FOOD HAZARD FACTOR SCREENING Application
下载PDF
Temporal and spatial study of differently charged ions emitted by ns-laser-produced tungsten plasmas using time-of-flight mass spectroscopy
19
作者 Ding WU George C-Y CHAN +4 位作者 Xianglei MAO Yu LI Richard E RUSSO Hongbin DING Vassilia ZORBA 《Plasma Science and Technology》 SCIE EI CAS CSCD 2021年第9期176-183,共8页
Tungsten(W)is an important material in tokamak walls and divertors.The W ion charge state distribution and the dynamic behavior of ions play important roles in the investigation of plasma–wall interactions using lase... Tungsten(W)is an important material in tokamak walls and divertors.The W ion charge state distribution and the dynamic behavior of ions play important roles in the investigation of plasma–wall interactions using laser-ablation-based diagnostics such as laser-induced breakdown spectroscopy and laser-induced ablation spectroscopy.In this work,we investigate the temporal and spatial evolutions of differently charged ions in a nanosecond-laser-produced W plasma in vacuum using time-of-flight mass spectroscopy.Ions with different charge states from 1 to 7(W+to W7+)are all observed.The temporal evolutions of the differently charged ions show that ions with higher charge states have higher velocities,indicating that space separation occurs between the differently charged ion groups.Spatially-resolved mass spectroscopy measurements further demonstrate the separation phenomenon.The temporal profile can be accurately fitted by a shifted Maxwell–Boltzmann distribution,and the velocities of the differently charged ions are also obtained from the fittings.It is found that the ion velocities increase continuously from the measured position of 0.75 cm to 2.25 cm away from the target surface,which indicates that the acceleration process lasts through the period of plasma expansion.The acceleration and space separation of the differently charged ions confirm that there is a dynamic plasma sheath in the laser-produced plasma,which provides essential information for the theoretical laser-ablation model with plasma formation and expansion. 展开更多
关键词 laser ablation temporal and spatial evolution time-of-flight mass spectroscopy spatial separation differently charged ions
下载PDF
MicrobMatcher: a microbial comparison software based on matrix-assisted laser desorption/ionization with time-of-flight mass spectrometry
20
作者 Yizhen Fu Feng Liu Yalu Ye 《Journal of Biomedical Science and Engineering》 2011年第5期403-409,共7页
Matrix-assisted Laser Desorption/Ionization with Time-of-flight Mass Spectrometry (MALDI-TOFMS) was investigated as a method for the rapid identifica-tion of species. Current demand in microbial identi-fication is how... Matrix-assisted Laser Desorption/Ionization with Time-of-flight Mass Spectrometry (MALDI-TOFMS) was investigated as a method for the rapid identifica-tion of species. Current demand in microbial identi-fication is how to compare unknown strains to the known one quickly, semi-automatically and accurately. In this paper, we present a software tool that allows flexibly microbial matching in a user-friendly way, by letting the users to customize comparison parameters including: in vitro transcription enzyme, mass tolerance,minimum fragment length, intensity threshold and corresponding weights. We provide three spectral scoring functions to compute the affin-ity between the species. Therefore, the precision of microbial comparison increases. To test and verify this tool, we employed experimental spectral data based on MALDI-TOFMS and the gene sequences of E.coli and Salmonella. This software is written in Java for cross-platform intention. 展开更多
关键词 MICROBIAL Comparison Matrix-Assisted Laser Desorption/Ionization with time-of-flight Mass SPECTROMETRY
下载PDF
上一页 1 2 8 下一页 到第