期刊文献+
共找到25,309篇文章
< 1 2 250 >
每页显示 20 50 100
Deep learning-based inpainting of saturation artifacts in optical coherence tomography images 被引量:2
1
作者 Muyun Hu Zhuoqun Yuan +2 位作者 Di Yang Jingzhu Zhao Yanmei Liang 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期1-10,共10页
Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts ... Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts and restore texture completely in OCT images.We proposed a deep learning-based inpainting method of saturation artifacts in this paper.The generation mechanism of saturation artifacts was analyzed,and experimental and simulated datasets were built based on the mechanism.Enhanced super-resolution generative adversarial networks were trained by the clear–saturated phantom image pairs.The perfect reconstructed results of experimental zebrafish and thyroid OCT images proved its feasibility,strong generalization,and robustness. 展开更多
关键词 Optical coherence tomography saturation artifacts deep learning image inpainting.
下载PDF
Triple-path feature transform network for ring-array photoacoustic tomography image reconstruction
2
作者 Lingyu Ma Zezheng Qin +1 位作者 Yiming Ma Mingjian Sun 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期23-40,共18页
Photoacoustic imaging(PAI)is a noninvasive emerging imaging method based on the photoacoustic effect,which provides necessary assistance for medical diagnosis.It has the characteristics of large imaging depth and high... Photoacoustic imaging(PAI)is a noninvasive emerging imaging method based on the photoacoustic effect,which provides necessary assistance for medical diagnosis.It has the characteristics of large imaging depth and high contrast.However,limited by the equipment cost and reconstruction time requirements,the existing PAI systems distributed with annular array transducers are difficult to take into account both the image quality and the imaging speed.In this paper,a triple-path feature transform network(TFT-Net)for ring-array photoacoustic tomography is proposed to enhance the imaging quality from limited-view and sparse measurement data.Specifically,the network combines the raw photoacoustic pressure signals and conventional linear reconstruction images as input data,and takes the photoacoustic physical model as a prior information to guide the reconstruction process.In addition,to enhance the ability of extracting signal features,the residual block and squeeze and excitation block are introduced into the TFT-Net.For further efficient reconstruction,the final output of photoacoustic signals uses‘filter-then-upsample’operation with a pixel-shuffle multiplexer and a max out module.Experiment results on simulated and in-vivo data demonstrate that the constructed TFT-Net can restore the target boundary clearly,reduce background noise,and realize fast and high-quality photoacoustic image reconstruction of limited view with sparse sampling. 展开更多
关键词 Deep learning feature transformation image reconstruction limited-view measurement photoacoustic tomography.
下载PDF
3D characterization and analysis of pore structure of packed ore particle beds based on computed tomography images 被引量:12
3
作者 杨保华 吴爱祥 +1 位作者 缪秀秀 刘金枝 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2014年第3期833-838,共6页
Methods and procedures of three-dimensional (3D) characterization of the pore structure features in the packed ore particle bed are focused. X-ray computed tomography was applied to deriving the cross-sectional imag... Methods and procedures of three-dimensional (3D) characterization of the pore structure features in the packed ore particle bed are focused. X-ray computed tomography was applied to deriving the cross-sectional images of specimens with single particle size of 1-2, 2-3, 3-4, 4-5, 5-6, 6-7, 7-8, 8-9, 9-10 ram. Based on the in-house developed 3D image analysis programs using Matlab, the volume porosity, pore size distribution and degree of connectivity were calculated and analyzed in detail. The results indicate that the volume porosity, the mean diameter of pores and the effective pore size (d50) increase with the increasing of particle size. Lognormal distribution or Gauss distribution is mostly suitable to model the pore size distribution. The degree of connectivity investigated on the basis of cluster-labeling algorithm also increases with increasing the particle size approximately. 展开更多
关键词 packed ore particle bed 3D pore structure X-ray computed tomography image analysis
下载PDF
Intravascular photoacoustic and optical coherence tomography imaging dual-mode system for detecting spontaneous coronary artery dissection: A feasibility study 被引量:1
4
作者 Yongwei Wang Yuyang Wan Zhongjiang Chen 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第1期77-86,共10页
In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary ... In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary artery dissection(SCAD)phantoms.IVPAI provides high-resolution and high-penetration images of intramural hematoma(IMH)at different depths,so it is especially useful for imaging deep blood clots associated with imaging phantoms.IVOCT can readily visualize the double-lumen morphology of blood vessel walls to identify intimal tears.We also demonstrate the capability of this dual-mode endoscopic system using mimicking phantoms and biological samples of blood clots in ex vivo porcine arteries.The results of the experiments indicate that the combined IVPAI and IVOCT technique has the potential to provide a more accurate SCAD assessment method for clinical applications. 展开更多
关键词 Spontaneous coronary artery dissection(SCAD) intravascular optical coherence tomography(IVOct) intravascular photoacoustic imaging(IVPAI)
下载PDF
Image reconstruction based on total-variation minimization and alternating direction method in linear scan computed tomography 被引量:6
5
作者 张瀚铭 王林元 +3 位作者 闫镔 李磊 席晓琦 陆利忠 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第7期582-589,共8页
Linear scan computed tomography (LCT) is of great benefit to online industrial scanning and security inspection due to its characteristics of straight-line source trajectory and high scanning speed. However, in prac... Linear scan computed tomography (LCT) is of great benefit to online industrial scanning and security inspection due to its characteristics of straight-line source trajectory and high scanning speed. However, in practical applications of LCT, there are challenges to image reconstruction due to limited-angle and insufficient data. In this paper, a new reconstruction algorithm based on total-variation (TV) minimization is developed to reconstruct images from limited-angle and insufficient data in LCT. The main idea of our approach is to reformulate a TV problem as a linear equality constrained problem where the objective function is separable, and then minimize its augmented Lagrangian function by using alternating direction method (ADM) to solve subproblems. The proposed method is robust and efficient in the task of reconstruction by showing the convergence of ADM. The numerical simulations and real data reconstructions show that the proposed reconstruction method brings reasonable performance and outperforms some previous ones when applied to an LCT imaging problem. 展开更多
关键词 linear scan ct image reconstruction total variation alternating direction method
下载PDF
Monochromatic energy computed tomography image for active intestinal hemorrhage:A model investigation 被引量:2
6
作者 Wen-Dong Liu Xing-Wang Wu +2 位作者 Jun-Mei Hu Bin Wang Bin Liu 《World Journal of Gastroenterology》 SCIE CAS 2015年第1期214-220,共7页
AIM: To investigate the value of computed tomography(CT) spectral imaging in the evaluation of intestinal hemorrhage.METHODS: Seven blood flow rates were simulated in vitro.Energy spectral CT and mixed-energy CT scans... AIM: To investigate the value of computed tomography(CT) spectral imaging in the evaluation of intestinal hemorrhage.METHODS: Seven blood flow rates were simulated in vitro.Energy spectral CT and mixed-energy CT scanswere performed for each rate(0.5,0.4,0.3,0.2,0.1,0.05 and 0.025 m L/min).The detection rates and the contrast-to-noise ratios(CNRs) of the contrast agent extravasation regions were compared between the two scanning methods in the arterial phase(AP) and the portal venous phase(PVP).Comparisons of the CNR values between the PVP and the AP were made for each energy level and carried out using a completely random t test.A χ2 test was used to compare the detection rates obtained from the two scanning methods.RESULTS: The total detection rates for energy spectral CT and mixed-energy CT in the AP were 88.57%(31/35) and 65.71%(23/35),respectively,and the difference was significant(χ2 = 5.185,P = 0.023); the total detection rates in the PVP were 100.00%(35/35) and 91.4%(32/35),respectively,and the difference was not significant(χ2 = 1.393,P = 0.238).In the AP,the CNR of the contrast agent extravasation regions was 3.58 ± 2.09 on the mixed-energy CT images,but the CNRs were 8.78 ± 7.21 and 8.83 ± 6.75 at 50 and 60 keV,respectively,on the single-energy CT images,which were significantly different(3.58 ± 2.09 vs 8.78 ± 7.21,P = 0.031; 3.58 ± 2.09 vs 8.83 ± 6.75,P = 0.029).In the PVP,the differences between the CNRs at 40,50 and 60 keV different monochromatic energy levels and the polychromatic energy images were significant(19.35 ± 10.89 vs 11.68 ± 6.38,P = 0.010; 20.82 ± 11.26 vs 11.68 ± 6.38,P = 0.001; 20.63 ± 10.07 vs 11.68 ± 6.38,P = 0.001).The CNRs at the different energy levels in the AP and the PVP were significantly different(t =-2.415,-2.380,-2.575,-2.762,-2.945,-3.157,-3.996 and-3.189).CONCLUSION: Monochromatic energy imaging spectral CT is superior to polychromatic energy images for the detection of intestinal hemorrhage,and the detection was easier in the PVP compared with the AP. 展开更多
关键词 Spectral imaging COMPUTED tomography MONOCHROMATIC
下载PDF
An algorithm for computed tomography image reconstruction from limited-view projections 被引量:5
7
作者 王林元 李磊 +3 位作者 闫镔 江成顺 王浩宇 包尚联 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第8期642-647,共6页
With the development of the compressive sensing theory, the image reconstruction from the projections viewed in limited angles is one of the hot problems in the research of computed tomography technology. This paper d... With the development of the compressive sensing theory, the image reconstruction from the projections viewed in limited angles is one of the hot problems in the research of computed tomography technology. This paper develops an iterative algorithm for image reconstruction, which can fit the most cases. This method gives an image reconstruction flow with the difference image vector, which is based on the concept that the difference image vector between the reconstructed and the reference image is sparse enough. Then the l1-norm minimization method is used to reconstruct the difference vector to recover the image for flat subjects in limited angles. The algorithm has been tested with a thin planar phantom and a real object in limited-view projection data. Moreover, all the studies showed the satisfactory results in accuracy at a rather high reconstruction speed. 展开更多
关键词 limited-view problem computed tomography image reconstruction algorithms reconstruction-reference difference algorithm adaptive steepest descent-projection onto convex sets algorithm
下载PDF
Pore structure of ore granular media by computerized tomography image processing 被引量:6
8
作者 吴爱祥 杨保华 +1 位作者 习泳 江怀春 《Journal of Central South University of Technology》 EI 2007年第2期220-224,共5页
The pore structure images of ore particles located at different heights of leaching column were scanned with X-ray computerized tomography (CT) scanner, the porosity and pore size distribution were calculated and the ... The pore structure images of ore particles located at different heights of leaching column were scanned with X-ray computerized tomography (CT) scanner, the porosity and pore size distribution were calculated and the geometrical shape and connectivity of pores were analyzed based on image process method, and the three dimensional reconstruction of pore structure images was realized. The results show that the porosity of ore particles bed in leaching column is 42.92%, 41.72%, 39.34% at top, middle and bottom zone, respectively. Obviously it has spatial variability and decreases appreciably along the height of the column. The overall average porosity obtained by image processing is 41.33% while the porosity gotten from general measurement method in laboratory is 42.77% showing the results of both methods are consistent well. The pore structure of ore granular media is characterized as a dynamical space network composed of interconnected pore bodies and pore throats. The ratio of throats with equivalent diameter less than 1.91 mm to the total pores is 29.31%, and that of the large pores with equivalent diameter more than 5.73 mm is 2.90%. 展开更多
关键词 ore granular media pore structure X-ray computerized tomography image processing
下载PDF
The risk of prostate cancer on incidental finding of an avid prostate uptake on 2-deoxy-2-[^(18)F]fluoro-D-glucose positron emission tomography/computed tomography for non-prostate cancer-related pathology:A single centre retrospective study
9
作者 Anthony Franklin Troy Gianduzzo +7 位作者 Boon Kua David Wong Louise McEwan James Walters Rachel Esler Matthew J.Roberts Geoff Coughlina John W.Yaxley 《Asian Journal of Urology》 CSCD 2024年第1期33-41,共9页
Objective:To review the risk of prostate cancer(PCa)in men with incidentally reported increased intraprostatic uptake at 2-deoxy-2-[18F]fluoro-d-glucose positron emission tomography/computed tomography(18F-FDG PET/CT)... Objective:To review the risk of prostate cancer(PCa)in men with incidentally reported increased intraprostatic uptake at 2-deoxy-2-[18F]fluoro-d-glucose positron emission tomography/computed tomography(18F-FDG PET/CT)ordered at Department of Urology,The Wesley Hospital,Brisbane,QLD,Australia for non-PCa related pathology.Methods:Retrospective analysis of consecutive men between August 2014 and August 2019 presenting to a single institution for 18F-FDG PET/CT for non-prostate related conditions was conducted.Men were classified as benign,indeterminate,or malignant depending of the results of prostate-specific antigen(PSA),PSA velocity,biopsy histopathology,and three-Tesla(3 T)multiparametric MRI(mpMRI)Prostate Imaging Reporting and Data System score,or gallium-68-prostate-specific membrane antigen(68Ga-PSMA)PET/CT results.Results:Three percent(273/9122)of men demonstrated 18F-FDG avidity within the prostate.Eighty-five percent(231/273)were further investigated,including with PSA tests(227/231,98.3%),3 T mpMRI(68/231,29.4%),68Ga-PSMA PET/CT(33/231,14.3%),and prostate biopsy(57/231,24.7%).Results were considered benign in 130/231(56.3%),indeterminate in 31/231(13.4%),and malignant in 70/231(30.3%).PCa was identified in 51/57(89.5%)of the men who proceeded to biopsy,including 26/27(96.3%)men with Prostate Imaging Reporting and Data System scores 4-5 mpMRI and six men with a positive 68Ga-PSMA PET/CT.The most common Gleason score on biopsy was greater than or equal to 4+5(14/51,27.5%).68Ga-PSMA PET/CT was concordant with the 18F-FDG findings in 26/33(78.8%).All 13 men with a positive concordant 18F-FDG,3 T mpMRI,and 68Ga-PSMA PET/CT had PCa on biopsy.There was no statistically significant difference in the 18F-FDG maximum standardized uptake value between the benign or malignant groups(5.7 vs.6.1;p=0.580).Conclusion:In this study,after an incidental finding of an avid intraprostatic lesion on 18F-FDG PET/CT,70 of the 231 cases(30.3%;0.8%of the entire cohort)had results consistent with PCa,most commonly as Gleason score greater than or equal to 4+5 disease.Unless there is limited life expectancy due to competing medical co-morbidity,men with an incidental finding of intraprostatic uptake on 18F-FDG should be further investigated using principles of PCa detection. 展开更多
关键词 Prostatecancer Positionemission tomography Multiparametric magneticresonance imaging Prostatebiopsy
下载PDF
Reconstruction of electrical capacitance tomography images based on fast linearized alternating direction method of multipliers for two-phase flow system 被引量:4
10
作者 Chongkun Xia Chengli Su +1 位作者 Jiangtao Cao Ping Li 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2016年第5期597-605,共9页
Electrical capacitance tomography(ECT)has been applied to two-phase flow measurement in recent years.Image reconstruction algorithms play an important role in the successful applications of ECT.To solve the ill-posed ... Electrical capacitance tomography(ECT)has been applied to two-phase flow measurement in recent years.Image reconstruction algorithms play an important role in the successful applications of ECT.To solve the ill-posed and nonlinear inverse problem of ECT image reconstruction,a new ECT image reconstruction method based on fast linearized alternating direction method of multipliers(FLADMM)is proposed in this paper.On the basis of theoretical analysis of compressed sensing(CS),the data acquisition of ECT is regarded as a linear measurement process of permittivity distribution signal of pipe section.A new measurement matrix is designed and L1 regularization method is used to convert ECT inverse problem to a convex relaxation problem which contains prior knowledge.A new fast alternating direction method of multipliers which contained linearized idea is employed to minimize the objective function.Simulation data and experimental results indicate that compared with other methods,the quality and speed of reconstructed images are markedly improved.Also,the dynamic experimental results indicate that the proposed algorithm can ful fill the real-time requirement of ECT systems in the application. 展开更多
关键词 Electrical capacitance tomography image reconstruction Compressed sensing Alternating direction method of multipliers Two-phase flow
下载PDF
Detecting early changes in choroidal vascularity and thickness using optical coherence tomography in patients with corneal crosslinking for keratoconus
11
作者 Selim Doganay Mehmet Omer Kiristioglu +1 位作者 Derya Doganay Elif Kacmaz 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第7期1267-1272,共6页
AIM:To investigate changes in choroidal thickness and vascularity in keratoconus patients treated with corneal crosslinking.METHODS:This study evaluated 28 eyes of 22 patients with keratoconus who underwent corneal cr... AIM:To investigate changes in choroidal thickness and vascularity in keratoconus patients treated with corneal crosslinking.METHODS:This study evaluated 28 eyes of 22 patients with keratoconus who underwent corneal crosslinking.The choroidal thicknesses were evaluated on enhanced depth imaging optical coherence tomography at the preoperative and postoperative 3d,1,and 3mo.Choroidal thickness in the four cardinal quadrants and the fovea were evaluated.The choroidal vascularity index was also calculated.RESULTS:There was no significant difference in central choroidal thickness between the preoperative and postoperative 3d,1mo(P>0.05).There was a significant increase in the 3mo(P=0.034)and a significant decrease in the horizontal choroidal vascularity index on the postoperative 3d(P=0.014),there was no statistically significant change in vertical axes and other visits in horizontal sections(P>0.05).CONCLUSION:This study sheds light on choroidal changes in postoperative corneal crosslinking for keratoconus.While it suggests the procedure’s relative safety for submacular choroid,more extensive research is necessary to confirm these findings and their clinical significance. 展开更多
关键词 KERATOCONUS corneal crosslinking choroidal vascularity index enhanced depth imaging optical coherence tomography
下载PDF
Impact of computed tomography/magnetic resonance imaging registration on rehabilitation after percutaneous endoscopic decompression for lumbar stenosis: Retrospective study
12
作者 Xiao-Bo Guo Jin-Wei Chen +1 位作者 Jun-Yang Liu Jiang-Tao Jin 《World Journal of Orthopedics》 2024年第10期939-949,共11页
BACKGROUND Percutaneous endoscopic lumbar decompression(PELD)shows promise for lumbar spinal stenosis(LSS)treatment,but its use is limited by the disease's complexity and procedural challenges.AIM In this study,th... BACKGROUND Percutaneous endoscopic lumbar decompression(PELD)shows promise for lumbar spinal stenosis(LSS)treatment,but its use is limited by the disease's complexity and procedural challenges.AIM In this study,the effects of preoperative planning and intraoperative guidance with computed tomography(CT)/magnetic resonance imaging(MRI)registration techniques on PELD for LSS and postoperative rehabilitation outcomes were evaluated.METHODS This retrospective study was conducted with data from patients who underwent PELD for LSS between January 2021 and December 2023.Patients were assigned to preoperative CT/MRI registration and control groups.Data collected included the operative time,length of hospital stay,visual analog scale(VAS)scores for low back and leg pain,and the Japanese Orthopaedic Association(JOA)lumbar spine score.Differences between groups were assessed using Student’s t test.RESULTS Data from 135 patients(71 in the CT/MRI registration group,64 in the control group)were analyzed.The operative time was significantly shorter in the CT/MRI registration group(P=0.007).At 2 months postoperatively,both groups showed significant reductions in VAS leg and low back pain scores(all P<0.001)and improvements in the JOA score(both P<0.001).No complication or death occurred.Preoperatively,pain and JOA scores were similar between groups(P=0.830,P=0.470,and P=0.287,respectively).At 2 months postoperatively,patients in the CT/MRI registration group reported lower leg and low back pain levels(P<0.001 and P=0.001,respectively)and had higher JOA scores(P=0.004)than did patients in the control group.CONCLUSION Preoperative CT/MRI registration for PELD for LSS reduced the operative time and VAS pain scores at 2 months and improved JOA scores,demonstrating enhanced effectiveness and safety. 展开更多
关键词 ENDOSCOPY Spinal stenosis Lumbar vertebrae tomography X-Ray computed Magnetic resonance imaging
下载PDF
基于CT影像儿童枢椎正常发育与变异的解剖特征
13
作者 吕绍茂 蓝佐珍 +2 位作者 吴文雪 池金澄 段少银 《中国组织工程研究》 CAS 北大核心 2025年第21期4545-4551,共7页
背景:枢椎发育演变过程复杂,研究报道较少。CT成像可以显示枢椎的正常发育过程、解剖结构、发育变异与畸形,明确枢椎骨化中心出现与骺板闭合时间及其演变过程和规律具有重要的临床价值。目的:基于CT影像展示儿童枢椎正常发育与变异的解... 背景:枢椎发育演变过程复杂,研究报道较少。CT成像可以显示枢椎的正常发育过程、解剖结构、发育变异与畸形,明确枢椎骨化中心出现与骺板闭合时间及其演变过程和规律具有重要的临床价值。目的:基于CT影像展示儿童枢椎正常发育与变异的解剖结构。方法:回顾性分析2016年6月至2019年11月行颈部扫描的732例0-15岁儿童CT图像。观察指标包括枢椎齿状突、双侧椎弓、椎体骨化中心,齿突尖部二次骨化中心,椎弓、齿突基底部及后正中骺板,以及枢椎发育变异或畸形。分析与比较各项指标在不同年龄下的变化情况,并利用SPSS 17.0统计学软件包进行数据分类处理及统计学分析。结果与结论:(1)732例研究对象包括枢椎正常发育718例(98.1%),畸形或发育异常14例(1.9%);(2)枢椎5个骨化中心,其中双侧椎弓及齿突、椎体骨化中心在出生时已出现;齿突尖部二次骨化中心出现的中位年龄是5.7岁,年龄四分位差(IQR)是4.1-7岁,最早出现的为8个月22 d,最迟未出现的为12岁10个月;(3)齿突尖骺板融合的中位年龄是6岁,IQR是5-8岁,未融合最大年龄是8岁9个月,融合的最小年龄是4岁3个月;(4)双侧椎弓骺板闭合的中位年龄约3.8岁,IQR约2.9-4.6岁,闭合的最小年龄是2岁3个月,未闭合的最大年龄是6岁;(5)齿突基底部骺板闭合的中位数5.2岁,IQR为3.5-6.8岁,闭合最小年龄是2岁6个月,最晚未闭合年龄是9岁6个月;(6)后正中骺板闭合年龄中位数为1.5岁,IQR为1.0-2.1岁,最晚未闭合2例分别为2岁5个月、14岁,最早闭合为6个月20 d;(7)枢椎畸形或发育异常,包括出现副骨化中心及副骺板7例、枢椎游离骨化小骨3例、后正中骺板不闭合2例、无齿突尖部二次骨化中心2例及枢椎齿突骨化中心未出现1例;(8)提示多层螺旋CT扫描、结合多平面重组技术可以完整显示枢椎的解剖结构,评估其正常发育变异及畸形。 展开更多
关键词 枢椎 骨化中心 骺板 发育与变异 ct影像
下载PDF
A machine learning-based strategy for predicting the mechanical strength of coral reef limestone using X-ray computed tomography
14
作者 Kai Wu Qingshan Meng +4 位作者 Ruoxin Li Le Luo Qin Ke ChiWang Chenghao Ma 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第7期2790-2800,共11页
Different sedimentary zones in coral reefs lead to significant anisotropy in the pore structure of coral reef limestone(CRL),making it difficult to study mechanical behaviors.With X-ray computed tomography(CT),112 CRL... Different sedimentary zones in coral reefs lead to significant anisotropy in the pore structure of coral reef limestone(CRL),making it difficult to study mechanical behaviors.With X-ray computed tomography(CT),112 CRL samples were utilized for training the support vector machine(SVM)-,random forest(RF)-,and back propagation neural network(BPNN)-based models,respectively.Simultaneously,the machine learning model was embedded into genetic algorithm(GA)for parameter optimization to effectively predict uniaxial compressive strength(UCS)of CRL.Results indicate that the BPNN model with five hidden layers presents the best training effect in the data set of CRL.The SVM-based model shows a tendency to overfitting in the training set and poor generalization ability in the testing set.The RF-based model is suitable for training CRL samples with large data.Analysis of Pearson correlation coefficient matrix and the percentage increment method of performance metrics shows that the dry density,pore structure,and porosity of CRL are strongly correlated to UCS.However,the P-wave velocity is almost uncorrelated to the UCS,which is significantly distinct from the law for homogenous geomaterials.In addition,the pore tensor proposed in this paper can effectively reflect the pore structure of coral framework limestone(CFL)and coral boulder limestone(CBL),realizing the quantitative characterization of the heterogeneity and anisotropy of pore.The pore tensor provides a feasible idea to establish the relationship between pore structure and mechanical behavior of CRL. 展开更多
关键词 Coral reef limestone(CRL) Machine learning Pore tensor X-ray computed tomography(ct)
下载PDF
Multidetector computer tomography and magnetic resonance imaging of double superior mesenteric veins:A case report
15
作者 Wei Tang Song Peng 《World Journal of Clinical Cases》 SCIE 2024年第17期3265-3270,共6页
BACKGROUND This study aimed to describe the findings of double superior mesenteric veins(SMVs),a rare anatomical variation,on multidetector computer tomography(MDCT)and magnetic resonance imaging(MRI)images.CASE SUMMA... BACKGROUND This study aimed to describe the findings of double superior mesenteric veins(SMVs),a rare anatomical variation,on multidetector computer tomography(MDCT)and magnetic resonance imaging(MRI)images.CASE SUMMARY We describe the case of a 34-year-old male,who underwent both MDC and MRI examinations of the upper abdomen because of liver cirrhosis.MDCT and MRI angiography images of the upper abdomen revealed an anatomic variation of the superior mesenteric vein(SMV),the double SMVs.CONCLUSION The double SMVs are a congenital abnormality without potential clinical manifestation.Physicians need to be aware of this anatomical variation during abdominal surgery to avoid iatrogenic injury. 展开更多
关键词 Superior mesenteric vein Anatomic variation Magnetic resonance imaging Multidetector computer tomography Case report
下载PDF
Phantom study of the impact of adaptive statistical iterative reconstruction (ASiR<sup>TM</sup>) on image quality for paediatric computed tomography 被引量:1
16
作者 Angjelina Protik Karen Thomas +1 位作者 Paul Babyn Nancy L. Ford 《Journal of Biomedical Science and Engineering》 2012年第12期793-806,共14页
Quantitative analysis of image quality will be helpful for designing ASiRTM-enhanced paediatric CT protocols, balancing image quality and radiation dose. Catphan600 phantom studies were performed on a GE Discovery HD7... Quantitative analysis of image quality will be helpful for designing ASiRTM-enhanced paediatric CT protocols, balancing image quality and radiation dose. Catphan600 phantom studies were performed on a GE Discovery HD750 64-slice CT scanner. Images were reconstructed with 0% - 100% ASiRTM (tube current 150 mA, variable kVp 80 - 140) in order to determine the optimal ASiRTM-Filtered Back Projection (FBP) blend. Images reconstructed with a 50% ASiRTM-50% FBP blend were compared to FBP images (0% ASiRTM) over a wide range of kVp (80 - 140) and mA (10 - 400) values. Measurements of image noise, CT number accuracy and uniformity, spatial and contrast resolution, and low contrast detectability were performed on axial and reformatted coronal images. Improvements in CNR, low contrast detectability and radial uniformity were observed in ASiRTM images compared to FBP images. 50% ASiRTM was associated with a 26% - 30% reduction in image noise. Changes in noise texture were observed at higher % ASiRTM blends with impact on visualisation of low and high contrast objects. A small decrease in limiting spatial resolution was detected with addition of ASiRTM, more appreciable at very low tube currents. The preferred blend for paediatric body protocols in our study, as determined by the image quality parameters investigated, was 50% ASiRTM when used with tube currents greater than 50 mA. 展开更多
关键词 image Analysis ct Optimization ASiRTM PAEDIATRIC Imaging
下载PDF
Effectiveness of magnetic resonance imaging and spiral computed tomography in the staging and treatment prognosis of colorectal cancer
17
作者 Lu-Na Bai Lu-Xian Zhang 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第7期2135-2144,共10页
BACKGROUND Colorectal cancer(CRC)is a prevalent cancer type in clinical settings;its early signs can be difficult to detect,which often results in late-stage diagnoses in many patients.The early detection and diagnosi... BACKGROUND Colorectal cancer(CRC)is a prevalent cancer type in clinical settings;its early signs can be difficult to detect,which often results in late-stage diagnoses in many patients.The early detection and diagnosis of CRC are crucial for improving treatment success and patient survival rates.Recently,imaging techniques have been hypothesized to be essential in managing CRC,with magnetic resonance imaging(MRI)and spiral computed tomography(SCT)playing a significant role in enhancing diagnostic and treatment approaches.AIM To explore the effectiveness of MRI and SCT in the preoperative staging of CRC and the prognosis of laparoscopic treatment.METHODS Ninety-five individuals admitted to Zhongshan Hospital Xiamen University underwent MRI and SCT and were diagnosed with CRC.The precision of MRI and SCT for the presurgical classification of CRC was assessed,and pathological staging was used as a reference.Receiver operating characteristic curves were used to evaluate the diagnostic efficacy of blood volume,blood flow,time to peak,permeability surface,blood reflux constant,volume transfer constant,and extracellular extravascular space volume fraction on the prognosis of patients with CRC.RESULTS Pathological biopsies confirmed the following CRC stages:23,23,32,and 17 at T1,T2,T3,and T4,respectively.There were 39 cases at the N0 stage,22 at N1,34 at N2,44 at M0 stage,and 51 at M1.Using pathological findings as the benchmark,the combined use of MRI and SCT for preoperative TNM staging in patients with CRC demonstrated superior sensitivity,specificity,and accuracy compared with either modality alone,with a statistically significant difference in accuracy(P<0.05).Receiver operating characteristic curve analysis revealed the predictive values for laparoscopic treatment prognosis,as indicated by the areas under the curve for blood volume,blood flow,time to peak,and permeability surface,blood reflux constant,volume transfer constant,and extracellular extravascular space volume fraction were 0.750,0.683,0.772,0.761,0.709,0.719,and 0.910,respectively.The corresponding sensitivity and specificity values were also obtained(P<0.05).CONCLUSION MRI with SCT is effective in the clinical diagnosis of patients with CRC and is worthy of clinical promotion. 展开更多
关键词 Magnetic resonance imaging Spiral computed tomography Colorectal cancer PROGNOSIS Receiver operating characteristic curve Retrospective study
下载PDF
Extravasated contrast volumetric assessment on computed tomography angiography in gastrointestinal bleeding:A useful predictor of positive angiographic findings
18
作者 Laura Maria Cacioppa Chiara Floridi +11 位作者 Alessandra Bruno NicolòRossini Tommaso Valeri Alessandra Borgheresi Riccardo Inchingolo Francesco Cortese Giacomo Novelli Alessandro Felicioli Mario Torresi Pietro Boscarato Letizia Ottaviani Andrea Giovagnoni 《World Journal of Radiology》 2024年第5期115-127,共13页
BACKGROUND Gastrointestinal bleeding(GIB)is a severe and potentially life-threatening condition,especially in cases of delayed treatment.Computed tomography angiography(CTA)plays a pivotal role in the early identifica... BACKGROUND Gastrointestinal bleeding(GIB)is a severe and potentially life-threatening condition,especially in cases of delayed treatment.Computed tomography angiography(CTA)plays a pivotal role in the early identification of upper and lower GIB and in the prompt treatment of the haemorrhage.AIM To determine whether a volumetric estimation of the extravasated contrast at CTA in GIB may be a predictor of subsequent positive angiographic findings.METHODS In this retrospective single-centre study,35 patients(22 men;median age 69 years;range 16-92 years)admitted to our institution for active GIB detected at CTA and further submitted to catheter angiography between January 2018 and February 2022 were enrolled.Twenty-three(65.7%)patients underwent endoscopy before CTA.Bleeding volumetry was evaluated in both arterial and venous phases via a semi-automated dedicated software.Bleeding rate was obtained from volume change between the two phases and standardised for unit time.Patients were divided into two groups,according to the angiographic signs and their concordance with CTA.RESULTS Upper bleeding accounted for 42.9%and lower GIB for 57.1%.Mean haemoglobin value at the admission was 7.7 g/dL.A concordance between positive CTA and direct angiographic bleeding signs was found in 19(54.3%)cases.Despite no significant differences in terms of bleeding volume in the arterial phase(0.55 mL vs 0.33 mL,P=0.35),a statistically significant volume increase in the venous phase was identified in the group of patients with positive angiography(2.06 mL vs 0.9 mL,P=0.02).In the latter patient group,a significant increase in bleeding rate was also detected(2.18 mL/min vs 0.19 mL/min,P=0.02).CONCLUSION In GIB of any origin,extravasated contrast volumetric analysis at CTA could be a predictor of positive angiography and may help in avoiding further unnecessary procedures. 展开更多
关键词 Gastrointestinal haemorrhage Computed tomography angiography Volumetric analysis Computer-assisted image interpretation Therapeutic embolization Transcatheter arterial embolization
下载PDF
Optimization-based image reconstruction in x-ray computed tomography by sparsity exploitation of local continuity and nonlocal spatial self-similarity 被引量:1
19
作者 张瀚铭 王林元 +3 位作者 李磊 闫镔 蔡爱龙 胡国恩 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第7期557-565,共9页
The additional sparse prior of images has been the subject of much research in problems of sparse-view computed tomography(CT) reconstruction. A method employing the image gradient sparsity is often used to reduce t... The additional sparse prior of images has been the subject of much research in problems of sparse-view computed tomography(CT) reconstruction. A method employing the image gradient sparsity is often used to reduce the sampling rate and is shown to remove the unwanted artifacts while preserve sharp edges, but may cause blocky or patchy artifacts.To eliminate this drawback, we propose a novel sparsity exploitation-based model for CT image reconstruction. In the presented model, the sparse representation and sparsity exploitation of both gradient and nonlocal gradient are investigated.The new model is shown to offer the potential for better results by introducing a similarity prior information of the image structure. Then, an effective alternating direction minimization algorithm is developed to optimize the objective function with a robust convergence result. Qualitative and quantitative evaluations have been carried out both on the simulation and real data in terms of accuracy and resolution properties. The results indicate that the proposed method can be applied for achieving better image-quality potential with the theoretically expected detailed feature preservation. 展开更多
关键词 computed tomography image reconstruction sparsity exploitation nonlocal gradient
下载PDF
Low-radiation and high image quality coronary computed tomography angiography in “real-world” unselected patients 被引量:3
20
作者 Caryl Elizabeth Richards Stephen Dorman +8 位作者 Patricia John Anthony Davies Sharon Evans Tishi Ninan David Martin Sriranj Kannoly Gail Roberts-Davies Mark Ramsey Daniel Rhys Obaid 《World Journal of Radiology》 2018年第10期135-142,共8页
AIM To determine the radiation dose and image quality in coronary computed tomography angiography(CCTA)using state-of-the-art dose reduction methods in unselected"real world"patients.METHODS In this single-c... AIM To determine the radiation dose and image quality in coronary computed tomography angiography(CCTA)using state-of-the-art dose reduction methods in unselected"real world"patients.METHODS In this single-centre study,consecutive patients in sinus rhythm underwent CCTA for suspected coronary artery disease(CAD)using a 320-row detector CT scanner.All patients underwent the standard CT acquisition protocol at our institute(Morriston Hospital)a combination of dose saving advances including prospective electrocardiogram-gating,automated tube current modulation,tube voltage reduction,heart rate reduction,and the most recent novel adaptive iterative dose reconstruction 3D(AIDR3D)algorithm.The cohort comprised real-world patients for routine CCTA who were not selected on age,body mass index,or heart rate.Subjective image quality was graded on a 4-point scale(4=excellent,1=non-diagnostic).RESULTS A total of 543 patients were included in the study with a mean body weight of 81±18 kg and a pre-scan mean heart rate of 70±11 beats per minute(bpm).When indicated,patients received rate-limiting medication with an oral beta-blocker followed by additional intravenous beta-blocker to achieve a heart rate below 65 bpm.The median effective radiation dose was 0.88 mSv(IQR,0.6-1.4 mSv)derived from a Dose Length Product of61.45 mGy.cm(IQR,42.86-100.00 mGy.cm).This also includes what we believe to be the lowest ever-reported radiation dose for a routine clinical CCTA(0.18 mSv).The mean image quality(SD)was 3.65±0.61,with a subjective image quality score of 3("good")or above for 93%of patient CCTAs.CONCLUSION Combining a low-dose scan protocol and AIDR3D with a 320-detector row CT scanner can provide high quality images at exceptionally low radiation dose in unselected patients being investigated for CAD. 展开更多
关键词 Effective RADIATION dose TUBE voltage TUBE current Iterative reconstruction Coronary COMPUTED tomography ANGIOGRAPHY image quality Prospectively ELEctROCARDIOGRAM GATING
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部