期刊文献+
共找到83篇文章
< 1 2 5 >
每页显示 20 50 100
Review of the Configuration and Transient Stability of Large-scale Renewable Energy Generation through Hybrid DC Transmission
1
作者 Xinshou Tian Yongning Chi +1 位作者 Longxue Li Hongzhi Liu 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期115-126,共12页
Based on the complementary advantages of Line Commutated Converter(LCC)and Modular Multilevel Converter(MMC)in power grid applications,there are two types of hybrid DC system topologies:one is the parallel connection ... Based on the complementary advantages of Line Commutated Converter(LCC)and Modular Multilevel Converter(MMC)in power grid applications,there are two types of hybrid DC system topologies:one is the parallel connection of LCC converter stations and MMC converter stations,and the other is the series connection of LCC and MMC converter stations within a single station.The hybrid DC transmission system faces broad application prospects and development potential in large-scale clean energy integration across regions and the construction of a new power system dominated by new energy sources in China.This paper first analyzes the system forms and topological characteristics of hybrid DC transmission,introducing the forms and topological characteristics of converter-level hybrid DC transmission systems and system-level hybrid DC transmission systems.Next,it analyzes the operating characteristics of LCC and MMC inverter-level hybrid DC transmission systems,provides insights into the transient stability of hybrid DC transmission systems,and typical fault ride-through control strategies.Finally,it summarizes the networking characteristics of the LCC-MMC series within the converter station hybrid DC transmission system,studies the transient characteristics and fault ridethrough control strategies under different fault types for the LCC-MMC series in the receiving-end converter station,and investigates the transient characteristics and fault ride-through control strategies under different fault types for the LCC-MMC series in the sending-end converter station. 展开更多
关键词 Hybrid DC transmission transient stability CONFIGURATION Control system
下载PDF
Migratable Power System Transient Stability AssessmentMethod Based on Improved XGBoost
2
作者 Ying Qu Jinhao Wang +4 位作者 Xueting Cheng Jie Hao Weiru Wang Zhewen Niu Yuxiang Wu 《Energy Engineering》 EI 2024年第7期1847-1863,共17页
The data-driven transient stability assessment(TSA)of power systems can predict online real-time prediction by learning the temporal features before and after faults.However,the accuracy of the assessment is limited b... The data-driven transient stability assessment(TSA)of power systems can predict online real-time prediction by learning the temporal features before and after faults.However,the accuracy of the assessment is limited by the quality of the data and has weak transferability.Based on this,this paper proposes a method for TSA of power systems based on an improved extreme gradient boosting(XGBoost)model.Firstly,the gradient detection method is employed to remove noise interference while maintaining the original time series trend.On this basis,a focal loss function is introduced to guide the training of theXGBoostmodel,enhancing the deep exploration of minority class samples to improve the accuracy of the model evaluation.Furthermore,to improve the generalization ability of the evaluation model,a transfer learning method based on model parameters and sample augmentation is proposed.The simulation analysis on the IEEE 39-bus system demonstrates that the proposed method,compared to the traditional machine learning-based transient stability assessment approach,achieves an average improvement of 2.16%in evaluation accuracy.Specifically,under scenarios involving changes in topology structure and operating conditions,the accuracy is enhanced by 3.65%and 3.11%,respectively.Moreover,the model updating efficiency is enhanced by 14–15 times,indicating the model’s transferable and adaptive capabilities across multiple scenarios. 展开更多
关键词 transient stability assessment DATA-DRIVEN segmented focusing approximation PORTABILITY
下载PDF
Optimal Allocation of STATCOM to Enhance Transient Stability Using Imperialist Competitive Algorithm
3
作者 Ayman Amer Firas MMakahleh +4 位作者 Jafar Ababneh Hani Attar Ahmed Amin Ahmed Solyman Mehrdad Ahmadi Kamarposhti Phatiphat Thounthong 《Intelligent Automation & Soft Computing》 SCIE 2023年第6期3425-3446,共22页
With the daily expansion of global energy consumption,developing the power grids is of uttermost importance.However,building a new trans-mission line is costly and time-consuming,so utilizing the same lines with possi... With the daily expansion of global energy consumption,developing the power grids is of uttermost importance.However,building a new trans-mission line is costly and time-consuming,so utilizing the same lines with possible higher transmission capacity is very cost-effective.In this regard,to increase the capacity of the transmission lines,the flexible alternating current transmission system(FACTS)has been widely used in power grids in recent years by industrialized countries.One of the essential topics in electrical power systems is the reactive power compensation,and the FACTS plays a significant role in controlling the reactive power current in the power grid and the system voltage oscillations and stability.When a static synchronous compensator(STATCOM)is embedded in a power system to increase the bus voltage,a supplementary damping controller can be designed to enhance the system oscillation damping.Given the expansion of the grids in the power system,the complexity of their optimization and the extraordinary ability of the imperialist competitive algorithm(ICA)for solving such problems,in this paper,the ICA has been used to determine the optimal position and size of the FACTS devices. 展开更多
关键词 STATCOM FACTS OPTIMIZATION transient stability imperialist competitive algorithm
下载PDF
A Nonlinear Coordinated Approach to Enhance the Transient Stability of Wind Energy-Based Power Systems 被引量:4
4
作者 Mohammad Javad Morshed 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2020年第4期1087-1097,共11页
This paper proposes a novel framework that enables the simultaneous coordination of the controllers of doubly fed induction generators(DFIGs) and synchronous generators(SGs).The proposed coordination approach is based... This paper proposes a novel framework that enables the simultaneous coordination of the controllers of doubly fed induction generators(DFIGs) and synchronous generators(SGs).The proposed coordination approach is based on the zero dynamics method aims at enhancing the transient stability of multi-machine power systems under a wide range of operating conditions. The proposed approach was implemented to the IEEE39-bus power systems. Transient stability margin measured in terms of critical clearing time along with eigenvalue analysis and time domain simulations were considered in the performance assessment. The obtained results were also compared to those achieved using a conventional power system stabilizer/power oscillation(PSS/POD) technique and the interconnection and damping assignment passivity-based controller(IDA-PBC). The performance analysis confirmed the ability of the proposed approach to enhance damping and improve system’s transient stability margin under a wide range of operating conditions. 展开更多
关键词 Doubly fed induction generator(DFIG) excitation controller multi-machine power system synchronous generator(SG) transient stability zero dynamics
下载PDF
Contribution to the Optimization of the Transient Stability of an Electric Power Transmission Network Using a Universal Power Flow Compensator Controlled by a Three-Stage Inverter 被引量:2
5
作者 Koko Koko Joseph Nneme Nneme Léandre Ndjakomo Essiane Salomé 《World Journal of Engineering and Technology》 2020年第4期675-688,共14页
The use of an electrical network as close as possible to its limits can lead to its instability in the event of a high amplitude disturbance. The damping of system oscillations can be achieved by conventional means of... The use of an electrical network as close as possible to its limits can lead to its instability in the event of a high amplitude disturbance. The damping of system oscillations can be achieved by conventional means of voltage and speed regulation but also by FACTS (Flexible AC Transmission Systems) devices, which are increasingly used in power networks. In this work, optimal control coordination between a hybrid power flow controller and a three-level inverter was used to improve the transient stability of a transmission line. The UPFC is a combination of a serial compensator (SSSC) and a parallel compensator (STATCOM) both connected to a DC-LINK DC bus. The SSSC acts as a voltage source for the network and injects a voltage that can be adjusted in phase and amplitude in addition to the network voltage;the STATCOM acts as a current source. The approach used is tested in the Matlab Simulink environment on a single machine network. Optimal controller tuning gives a better transient stability improvement by reducing the transport angle oscillations from 248.17% to 9.85%. 展开更多
关键词 FACTS UPFC Three-Stage Inverter PI Power Transit transient stability
下载PDF
Transient Stability Assessment of Synchronous Generator in Power System with High-Penetration Photovoltaics 被引量:2
6
作者 Masaki Yagami Takahiko Hasegawa Junji Tamura 《Journal of Mechanics Engineering and Automation》 2012年第12期762-768,共7页
As photovoltaic (PV) capacity in power system increases, the capacity of synchronous generator needs to be reduced relatively. This leads to the lower system inertia and the higher generator reactance, and hence the... As photovoltaic (PV) capacity in power system increases, the capacity of synchronous generator needs to be reduced relatively. This leads to the lower system inertia and the higher generator reactance, and hence the generator transient stability may negatively be affected. In particular, the impact on the transient stability may become more serious when the considerable amounts of PV systems are disconnected simultaneously during voltage sag. In this work, the generator transient stability in the power system with significant PV penetration is assessed by a numerical simulation. In order to assess the impact from various angles, simulation parameters such as levels of PV penetration, variety of power sources (inverter or rotational machine), and existence of LVRT capability are considered. The simulation is performed by using PSCAD/EMTDC software. 展开更多
关键词 High-penetration photovoltaics low-voltage ride-through (LVRT) synchronous generator transient stability.
下载PDF
Transient Stability Analysis of Power System with Photovoltaic Systems Installed 被引量:1
7
作者 Masaki Yagami Seiichiro Ishikawa +2 位作者 Yoshihiro Ichinohe Kenji Misawa Junji Tamura 《Journal of Energy and Power Engineering》 2015年第10期896-904,共9页
The impact of large-scale grid-connected PV (photovoltaics) on power system transient stability is discussed in this paper. In response to an increase of PV capacity, the capacity of conventional synchronous generat... The impact of large-scale grid-connected PV (photovoltaics) on power system transient stability is discussed in this paper. In response to an increase of PV capacity, the capacity of conventional synchronous generator needs to be reduced relatively. This leads to the lower system inertia and the higher generator reactance, and hence, the power system transient stability may negatively be affected. In particular, the impact on the transient stability may become more serious when the considerable amounts of PV systems are disconnected simultaneously during voltage sag. In this work, the potential impact of significant PV penetration on the transient stability is assessed by a numerical simulation using PSCAD/EMTDC. 展开更多
关键词 PHOTOVOLTAIC LVRT (low-voltage ride-through) synchronous generator infinite bus transient stability.
下载PDF
Transient Stability Analysis Using Transmission Line Measurement
8
作者 蔡国伟 程浩忠 +1 位作者 陈家荣 王承民 《Journal of Shanghai Jiaotong university(Science)》 EI 2004年第2期29-35,共7页
The novel quantitative assessment method using transmission line measurement was developed. A new style of stability criterion was suggested which is based on the line measurement. The stability indices for lines, cut... The novel quantitative assessment method using transmission line measurement was developed. A new style of stability criterion was suggested which is based on the line measurement. The stability indices for lines, cutsets and power system according to features of transient energy in the lines were given, which not only provide a reliable and accurate assessment of the transient stability of power system, but also can be used to assess the effect of lines and cutsets on the transient stability and identify the weak transmission segment. Examples were presented by simulation on the IEEE-39 buses test system. 展开更多
关键词 power system transient stability local network measurement stability criterion line stability index cutset stability index
下载PDF
An Optimal DF Based Method for Transient Stability Analysis
9
作者 Z.A.Zaki Emad M.Ahmed +1 位作者 Ziad M.Ali Imran Khan 《Computers, Materials & Continua》 SCIE EI 2022年第2期3449-3471,共23页
The effect of energy on the natural environment has become increasingly severe as human consumption of fossil energy has increased.The capacity of the synchronous generators to keep working without losing synchronizat... The effect of energy on the natural environment has become increasingly severe as human consumption of fossil energy has increased.The capacity of the synchronous generators to keep working without losing synchronization when the system is exposed to severe faults such as short circuits is referred to as the power system’s transient stability.As the power system’s safe and stable operation and mechanism of action become more complicated,higher demands for accurate and rapid power system transient stability analysis are made.Current methods for analyzing transient stability are less accurate because they do not account formisclassification of unstable samples.As a result,this paper proposes a novel approach for analyzing transient stability.The key concept is to use deep forest(DF)and a neighborhood rough reduction approach together.Using the neighborhood rough sets,the original feature space is obtained by creating many optimal feature subsets at various granularity levels.Then,by deploying the DF cascade structure,the mapping connection between the transient stability state and the features is reinforced.The weighted voting technique is used in the learning process to increase the classification accuracy of unstable samples.When contrasted to current methods,simulation results indicate that the proposed approach outperforms them. 展开更多
关键词 transient stability analysis power system cascade structure optimal power flow
下载PDF
Transient Stability Analysis of Synchronous Generator in Power System with Renewable Power Sources Installed
10
作者 Masaki Yagami Yoshihiro Ichinohe +2 位作者 Yohichiro Kojima Kenji Misawa Junji Tamura 《Journal of Mechanics Engineering and Automation》 2016年第8期400-407,共8页
The impact of large-scale grid-connected renewable power sources, such as wind generators and solar photovoitaic systems, on transient stability of synchronous generators is discussed in this paper. The permanent magn... The impact of large-scale grid-connected renewable power sources, such as wind generators and solar photovoitaic systems, on transient stability of synchronous generators is discussed in this paper. The permanent magnet synchronous generator with variable speed wind turbine is used in the simulation analysis as a wind generator model. The transient stability analysis is performed for IEEE 9-bus system model with high-penetration renewable power sources. The effect of FRT (fault ride-through) capability implemented for each power source on the transient stability is investigated. 展开更多
关键词 Fault ride-through variable speed wind generator PHOTOVOLTAIC synchronous generator transient stability.
下载PDF
Transient Stability Assessment of Synchronous Generator in Power System with High-Penetration Photovoltaics (Part 2)
11
作者 Masaki Yagami Seiichiro lshikawa +2 位作者 Yoshihiro Ichinohe Kenji Misawa Junji Tamura 《Journal of Mechanics Engineering and Automation》 2015年第7期401-406,共6页
In the previous paper [1], the transient stability of synchronous generator in power system with high-penetration PV (photovoltaic) was assessed by simulation analysis of a single-machine infinite-bus system model. ... In the previous paper [1], the transient stability of synchronous generator in power system with high-penetration PV (photovoltaic) was assessed by simulation analysis of a single-machine infinite-bus system model. Through the simulation analysis, we have obtained some conclusions in terms of the impact of high-penetration PV on the stability. However, for more accurate assessment of the transient stability, it is necessary to analyze various simulation models considering many other power system conditions. This paper presents the results of the analysis for the transient stability simulation performed for IEEE 9-bus system model, in which the effects of various conditions, such as variety of power sources (inverter or rotational machine), load characteristics, existence of LVRT (low-voltage ride-through) capability and fault locations, on the transient stability are investigated. 展开更多
关键词 High-penetration photovoltaics LVRT (low-voltage ride-through) synchronous generator transient stability
下载PDF
Design-oriented Transient Stability Assessment for Droop-controlled Converter Considering Grid Voltage Phase-angle Jump
12
作者 Pingjuan Ge Hailiang Xu +3 位作者 Ruitong Mao Chunming Tu Fan Xiao Qi Guo 《Chinese Journal of Electrical Engineering》 EI CSCD 2024年第3期63-76,共14页
Droop-controlled voltage-source converters(VSCs)can provide frequency and voltage support to power grids.However,during a grid fault,VsCs may experience transient instability,which can be significantly affected by bot... Droop-controlled voltage-source converters(VSCs)can provide frequency and voltage support to power grids.However,during a grid fault,VsCs may experience transient instability,which can be significantly affected by both the control parameters and fault conditions.This mechanism has not been fully elucidated in previous studies.In particular,grid-voltage faults are commonly accompanied by a grid voltage phase-angle jump(VPAJ),which is typically ignored in the evaluation of the transient stability of VSCs.To address this issue,this study comprehensively assesses the impact of the VPAJ and key control parameters on the transient characteristics of VSCs.Furthermore,the critical clearing angle and critical clearing time are quantitatively calculated to define the transient stability boundary.In addition,a transient stability-enhancement control method that considers the transient stability constraints is proposed.Finally,simulations and experimental tests are conducted to validate both the theoretical analysis and proposed method. 展开更多
关键词 Droop-controlled VSC grid voltage phase-angle jump(VPAJ) transient stability boundary transient stability assessmentcontrol
原文传递
Hybrid Analytical and Data-Driven Model Based Instance-Transfer Method for Power System Online Transient Stability Assessment 被引量:1
13
作者 Feng Li Qi Wang +2 位作者 Yi Tang Yan Xu Jie Dang 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第4期1664-1675,共12页
Data-driven methods are widely recognized and generate conducive results for online transient stability assessment.However,the tedious and time-consuming process of sample collection is often overlooked.The functionin... Data-driven methods are widely recognized and generate conducive results for online transient stability assessment.However,the tedious and time-consuming process of sample collection is often overlooked.The functioning of power systems involves repetitive sample collection due to the constant variations occurring in the operation mode,thereby highlighting the importance of collection efficiency.As a means to achieve high sample collection efficiency following the operation mode change,we propose a novel instance-transfer method based on compression and matching strategy,which facilitates the direct acquisition of useful previous samples,used for creating the new sample base.Additionally,we present a hybrid model to ensure rationality in the process of sample similarity comparison and selection,where features of analytical modeling with special significance are introduced into data-driven methods.At the same time,a data-driven method can also be integrated in the hybrid model to achieve rapid error correction of analytical models,enabling fast and accurate post-disturbance transient stability assessment.As a paradigm,we consider a scheme for online critical clearing time estimation,where integrated extended equal area criterion and extreme learning machine are employed as analytical model part and data-driven error correction model part,respectively.Derived results validate the credible efficacy of the proposed method. 展开更多
关键词 Critical clearing time extreme learning machine instance-transfer method transient stability assessment
原文传递
Transient Stability Analysis of Converter-based Islanded Microgrids Based on Iterative Equal Area Criterion Considering Reactive Power Loop Dynamics and Varying Damping
14
作者 Xilin Li Jingyi Zhang +4 位作者 Zhen Tian Xiaoming Zha Wei Wang Meng Huang Chong Shao 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第4期1170-1182,共13页
With the rapid increase in the installed capacity of renewable energy in modern power systems,the stable operation of power systems with considerable power electronic equipment requires further investigation.In conver... With the rapid increase in the installed capacity of renewable energy in modern power systems,the stable operation of power systems with considerable power electronic equipment requires further investigation.In converter-based islanded microgrid(CIM)systems equipped with grid-following(GFL)and grid-forming(GFM)voltage-source converters(VSCs),it is challenging to maintain stability due to the mutual coupling effects between different VSCs and the loss of voltage and frequency support from the power system.In previous studies,quantitative transient stability analysis was primarily used to assess the active power loop of GFM-VSCs.However,frequency and voltage dynamics are found to be strongly coupled,which strongly affects the estimation result of stability boundary.In addition,the vary-ing damping terms have not been fully captured.To bridge these gaps,this paper investigates the transient stability of CIM consid-ering reactive power loop dynamics and varying damping.First,an accuracy-enhanced nonlinear model of the CIM is derived based on the effects of reactive power loop and post-disturbance frequency jump phenomena.Considering these effects will eliminates the risk of misjudgment.The reactive power loop dynamics make the model coefficients be no longer constant and thus vary with the power angle.To evaluate quantitatively the effects of re-active power loop and varying damping on the transient stability of CIM,an iterative criterion based on the equal area criterion theory is proposed.In addition,the effects of parameters on the stable boundary of power system are analyzed,and the dynamic interaction mechanisms are revealed.Simulation and experiment results verify the merits of the proposed method. 展开更多
关键词 transient stability CONVERTER iterative criterion reactive power loop post-disturbance frequency jump
原文传递
Transient Stability Analysis of Grid-connected Converters in Wind Turbine Systems Based on Linear Lyapunov Function and Reverse-time Trajectory
15
作者 Mohammad Kazem Bakhshizadeh Sujay Ghosh +1 位作者 Guangya Yang Łukasz Kocewiak 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第3期782-790,共9页
As the proportion of converter-interfaced renewable energy resources in the power system is increasing,the strength of the power grid at the connection point of wind turbine generators(WTGs)is gradually weakening.Exis... As the proportion of converter-interfaced renewable energy resources in the power system is increasing,the strength of the power grid at the connection point of wind turbine generators(WTGs)is gradually weakening.Existing research has shown that when connected with the weak grid,the stability of the traditional grid-following controlled converters will deteriorate,and they are prone to unstable phenomena such as oscillation.Due to the limitations of linear analysis that cannot sufficiently capture the stability phenomena,transient stability must be investigated.So far,standalone time-domain simulations or analytical Lyapunov stability criteria have been used to investigate transient stability.However,the time-domain simulations have proven to be computationally too heavy,while analytical methods are difficult to formulate for larger systems,require many modelling assumptions,and are often conservative in estimating the stability boundary.This paper proposes and demonstrates an innovative approach to estimating the transient stability boundary via combining the linear Lyapunov function and the reverse-time trajectory technique.The proposed methodology eliminates the need of time-consuming simulations and the conservative nature of Lyapunov functions.This study brings out the clear distinction between the stability boundaries with different post-fault active current ramp rate controls.At the same time,it provides a new perspective on critical clearing time for wind turbine systems.The stability boundary is verified using time-domain simulation studies. 展开更多
关键词 Lyapunov direct method non-autonomous system phase-locked loop(PLL) time trajectory reversal transient stability assessment wind turbine converter system
原文传递
Transient Stability Analysis and Design of VSGs with Different DC-Link Voltage Controllers
16
作者 Chao Shen Wei Gu +1 位作者 Wanxing Sheng Keyan Liu 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第2期593-604,共12页
Virtual synchronous control has been widely studied for the advantages of emulating inertia for voltage source converters (VSCs). A constant dc-link voltage is usually assumed in existing literature to estimate transi... Virtual synchronous control has been widely studied for the advantages of emulating inertia for voltage source converters (VSCs). A constant dc-link voltage is usually assumed in existing literature to estimate transient stability of virtual synchronous generators (VSGs). However, actual power supply in the dc-side of VSGs is limited and different dc-link voltage controllers are needed to achieve power balance between DC side and AC side. Addition of dc-link voltage controller has great influence on transient behavior of VSGs, which has not been investigated by previous research. To fill this gap, this paper gives insights into the effect of dc-link voltage dynamics on transient stability of VSGs. First, two typical kinds of VSGs with dc-link voltage controllers are introduced. Then, mathematical models considering dc-link dynamics are established and the effect of dc-link voltage controllers on transient synchronization stability of VSGs is revealed through equal area criterion (EAC). It is found that dc-link voltage controller would reduce stability margin of VSGs and design-oriented transient stability analysis is carried out quantitively using critical clearing time (CCT). Finally, simulation results are given to validate correctness of theoretical analysis. 展开更多
关键词 DC-link voltage dynamics equal area criterion(eac) transient synchronization stability virtual synchronous generator(VSG)
原文传递
Distributed Deep Reinforcement Learning-based Approach for Fast Preventive Control Considering Transient Stability Constraints 被引量:5
17
作者 Hongtai Zeng Yanzhen Zhou +2 位作者 Qinglai Guo Zhongmin Cai Hongbin Sun 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第1期197-208,共12页
Preventive transient stability control is an effective measure for the power system to withstand high-probability severe contingencies.It is mathematically an optimal power flow problem with transient stability constr... Preventive transient stability control is an effective measure for the power system to withstand high-probability severe contingencies.It is mathematically an optimal power flow problem with transient stability constraints.Due to the constraints involved for differential algebraic equations of transient stability,it is difficult and time-consuming to solve this problem.To address these issues,this paper presents a novel deep reinforcement learning(DRL)framework for preventive transient stability control of power systems.A distributed deep deterministic policy gradient is utilized to train a DRL agent that can learn its control policy through massive interactions with a grid simulator.Once properly trained,the DRL agent can instantaneously provide effective strategies to adjust the system to a safe operating position with a near-optimal operational cost.The effectiveness of the proposed method is verified through numerical experiments conducted on a New England 39-bus system and NPCC 140-bus system. 展开更多
关键词 Deep reinforcement learning preventive Control transient stability
原文传递
Data-driven Transient Stability Assessment Using Sparse PMU Sampling and Online Self-check Function 被引量:4
18
作者 Guozheng Wang Jianbo Guo +4 位作者 Shicong Ma Xi Zhang Qinglai Guo Shixiong Fan Haotian Xu 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第3期910-920,共11页
Artificial intelligence technologies provide a newapproach for the real-time transient stability assessment (TSA)of large-scale power systems. In this paper, we propose a datadriven transient stability assessment mode... Artificial intelligence technologies provide a newapproach for the real-time transient stability assessment (TSA)of large-scale power systems. In this paper, we propose a datadriven transient stability assessment model (DTSA) that combinesdifferent AI algorithms. A pre-AI based on the time-delay neuralnetwork is designed to locate the dominant buses for installingthe phase measurement units (PMUs) and reducing the datadimension. A post-AI is designed based on the bidirectionallong-short-term memory network to generate an accurate TSAwith sparse PUM sampling. An online self-check function of theonline TSA’s validity when the power system changes is furtheradded by comparing the results of the pre-AI and the post-AI.The IEEE 39-bus system and the 300-bus AC/DC hybrid systemestablished by referring to China’s existing power system areadopted to verify the proposed method. Results indicate that theproposed method can effectively reduce the computation costswith ensured TSA accuracy as well as provide feedback forits applicability. The DTSA provides new insights for properlyintegrating varied AI algorithms to solve practical problems inmodern power systems. 展开更多
关键词 Artificial intelligence phasor measurement units recurrent neural networks transient stability assessment
原文传递
Static information, K-neighbor, and self-attention aggregated scheme: a transient stability prediction model with enhanced interpretability 被引量:4
19
作者 Liukai Chen Lin Guan 《Protection and Control of Modern Power Systems》 SCIE EI 2023年第1期81-96,共16页
Data-driven preventive scanning for transient stability assessment(DTSA)is a faster and more efficient solution than time-domain simulation(TDS).However,most current methods cannot balance generalization to different ... Data-driven preventive scanning for transient stability assessment(DTSA)is a faster and more efficient solution than time-domain simulation(TDS).However,most current methods cannot balance generalization to different topolo-gies and interpretability,with simple output.A model that conforms to the physical mechanism and richer label for transient stability can increase confidence in DTSA.Thus a static-information,k-neighbor,and self-attention aggre-gated schema(SKETCH)is proposed in this paper.Taking only static measurements as input,SKETCH gives several explanations that are consistent with the physical mechanisms of TSA and provides results for all generator stability while predicting system stability.A module based on the self-attention mechanism is designed to solve the locality problem of a graph neural network(GNN),achieving subgraph equivalence outside the k-order neighborhood.Test re sults on the IEEE 39-bus system and IEEE 300-bus system indicate the superiority of SKETCH and also demonstrate the rich sample interpretation results. 展开更多
关键词 transient stability assessment(TSA) DATA-DRIVEN Explainable Graph neural network(GNN) Self-attention
原文传递
Data-driven Estimation for a Region of Attraction for Transient Stability Using the Koopman Operator 被引量:1
20
作者 Le Zheng Xin Liu +2 位作者 Yanhui Xu Wei Hu Chongru Liu 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第4期1405-1413,共9页
This paper presents a novel Koopman Operator based framework to estimate the region of attraction for power system transient stability analysis.The Koopman eigenfunctions are used to numerically construct a Lyapunov f... This paper presents a novel Koopman Operator based framework to estimate the region of attraction for power system transient stability analysis.The Koopman eigenfunctions are used to numerically construct a Lyapunov function.Then the level set of the function is utilized to estimate the boundary of the region of attraction.The method provides a systematic method to construct the Lyapunov function with data sampled from the state space,which suits any power system models and is easy to use compared to traditional Lyapunov direct methods.In addition,the constructed Lyapunov function can capture the geometric properties of the region of attraction,thus providing useful information about the instability modes.The method has been verified by a simple illustrative example and three power system models,including a voltage source converter interfaced system to analyze the large signal synchronizing instability induced by the phase lock loop dynamics.The proposed method provides an alternative approach to understanding the geometric properties and estimating the boundary of the region of attraction of power systems in a data driven manner.Index Terms-Koopman operator,lyapunov function,power system transient stability,region of attraction. 展开更多
关键词 Koopman operator lyapunov function power system transient stability region of attraction.
原文传递
上一页 1 2 5 下一页 到第
使用帮助 返回顶部