期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Electrical Energy Quality Analysis in Hospital Centres
1
作者 Abdourahimoun Daouda Sani Idi Boubabacar +1 位作者 Moctar Mossi Idrissa Saidou Madougou 《Smart Grid and Renewable Energy》 2021年第4期53-63,共11页
<span style="font-family:Verdana;">Today, energy is a vital component in the functioning of a hospital. Hospital technical facilities have several types of technologies, these include appliances for us... <span style="font-family:Verdana;">Today, energy is a vital component in the functioning of a hospital. Hospital technical facilities have several types of technologies, these include appliances for use;examination apparatus. So, for Quality Health Care in a hospital, there is</span><span style="font-family:Verdana;"> a</span><span style="font-family:Verdana;"> need to ensure the proper functioning of hospital equipment. In addition to the required maintenance as specified by the device manufacturer, </span><span style="font-family:Verdana;">the </span><span style="font-family:Verdana;">quality of the electrical energy across the device must be ensured. This article is an analysis of the quality of electric energy at the substation of National Hospital of Niamey. Thereby, the data collection, followed by the data processing and analysis revealed the parameters characterizing the quality of electrical energy across the substation. Our studies have shown that the substation is underutilized as the maximum inrush current is less than half the available current. </span><span style="font-family:Verdana;">The </span><span style="font-family:Verdana;">current </span><span style="font-family:Verdana;">was </span><span style="font-family:Verdana;">consumed by the three phases ha</span><span style="font-family:Verdana;">s</span><span style="font-family:Verdana;"> resulted </span><span style="font-family:Verdana;">in</span><span style="font-family:Verdana;"> a strong current unbalance (230</span><span style="font-family:;" "=""> </span><span style="font-family:Verdana;">A). However, the current unbalance and the voltage amplitude</span><span style="font-family:Verdana;">,</span><span style="font-family:Verdana;"> are admissible according</span><span style="font-family:Verdana;">ly</span><span style="font-family:Verdana;"> base on EN50160 standard. Furthermore, the harmonics voltages present in this medium </span><span style="font-family:Verdana;">are</span><span style="font-family:Verdana;"> in the accepted range (1.8%) according to IEEE 519 standard. However, the fundamental frequency does not meet the standard, but the difference obtained has no adverse effect.</span> 展开更多
关键词 ANALYSIS Quality of Electrical Energy Distribution Network current unbalance Harmonic Disturbance
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部