期刊文献+
共找到10篇文章
< 1 >
每页显示 20 50 100
Optimal Power Flow Using Firefly Algorithm with Unified Power Flow Controller
1
作者 T. Hariharan K. Mohana Sundaram 《Circuits and Systems》 2016年第8期1934-1942,共10页
Firefly algorithm is the new intelligent algorithm used for all complex engineering optimization problems. Power system has many complex optimization problems one of which is the optimal power flow (OPF). Basically, i... Firefly algorithm is the new intelligent algorithm used for all complex engineering optimization problems. Power system has many complex optimization problems one of which is the optimal power flow (OPF). Basically, it is minimizing optimization problem and subjected to many complex objective functions and constraints. Hence, firefly algorithm is used to solve OPF in this paper. The aim of the firefly is to optimize the control variables, namely generated real power, voltage magnitude and tap setting of transformers. Flexible AC Transmission system (FACTS) devices may used in the power system to improve the quality of the power supply and to reduce the cost of the generation. FACTS devices are classified into series, shunt, shunt-series and series-series connected devices. Unified power flow controller (UPFC) is shunt-series type device that posses all capabilities to control real, reactive powers, voltage and reactance of the connected line in the power system. Hence, UPFC is included in the considered IEEE 30 bus for the OPF solution. 展开更多
关键词 Real power Loss Fuel Cost Optimal power flow unified power flow controller Firefly Algorithm
下载PDF
Harmonic influence analysis of unified power flow controller based on modular multilevel converter 被引量:15
2
作者 Yubo YUAN Peng LI +3 位作者 Xiangping KONG Jiankun LIU Qun LI Ye WANG 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2016年第1期10-18,共9页
The unified power flow controller(UPFC)based on modular multilevel converter(MMC) is the most creative flexible ac transmission system(FACTS) device. In theory, the output voltage of the series MMC in MMCUPFC can be r... The unified power flow controller(UPFC)based on modular multilevel converter(MMC) is the most creative flexible ac transmission system(FACTS) device. In theory, the output voltage of the series MMC in MMCUPFC can be regulated from 0 to the rated value. However,there would be relatively large harmonics in the output voltage if the voltage modulation ratio is small. In order to analyze the influence of MMC-UPFC on the harmonics of the power grid, the theoretical calculation method and spectra of the output voltage harmonics of MMC are presented. Subsequently, the calculation formulas of the harmonics in the power grid with UPFC are proposed. Based on it, the influence of UPFC on the grid voltage harmonics is evaluated, when MMC-UPFC is operated with different submodular numbers and voltage modular ratios. Eventually, the proposed analysis method is validated using digital simulation. The study results would provide guideline for the design and operation of MMC-UPFC project. 展开更多
关键词 unified power flow controller(UPFC) Modular multilevel converter(MMC) Harmonic features Voltage modulation ratio Submodular number
原文传递
Investigation of Real Power Flow Control of AI Based MC-UPFC in FACTS Controllers
3
作者 Boopalan Chandran Saravanan Vasudevan Raghavendiran TA 《Journal of Energy and Power Engineering》 2020年第4期111-130,共20页
The power consumption is rapidly increased due to ASD(Adjustable Speed Drives)and automation in industries and large consumption of electricity in domestic regions increased the concern of the power quality.The qualit... The power consumption is rapidly increased due to ASD(Adjustable Speed Drives)and automation in industries and large consumption of electricity in domestic regions increased the concern of the power quality.The quality of the power received in the distribution system is altered because of the losses in the transmission system.The losses in the transmission system are mitigated using the FACTS(Flexible AC Transmission System)controller,among these controllers UPFC(Unified Power Flow Controller)plays a vital role in controlling the shunt and series reactive powers in the bus of the power system.The conventional topology of the UPFC consists of AC-DC converter and energy stored in the DC link and DC-AC converter injected a voltage in series to the bus which is to be controlled.Whereas a new topology based on matrix converter can replace the dual converters and perform the required task.The construction of 2-bus,7-bus and IEEE-14-bus power system is designed and modeled.MC-UPFC(Matrix Converter Based Unified Power Flow Controller)is designed and constructed.The MC-UPFC is the rich topology in the FACTS which is capable of controlling both the transmission parameters simultaneously with the switching technique of direct power control by the smooth sliding control which gives less ripple in the injecting control parameters such as control voltage(Vc)and voltage angle(α).By implementing MC-UPFC the real and reactive power can be controlled simultaneously and independently.The control techniques were designed based on the PID(Proportional Integral Derivative)with sliding surface power control,FLC(Fuzzy Logic Controller)and ANN(Artificial Neural Network)and the performances of Vc andαof the controllers are investigated.Hence the sliding surface and relevant control switching state of the MC can be controlled by the FLC which gives the robust and autonomous decision made in the selection of the appropriate switching state for the effective real power control in the power system.The work has been carried out in the MATLAB Simulink simulator which gives the finest controlling features and simple design procedures and monitoring of the output. 展开更多
关键词 Matrix converter unified power flow controller fuzzy logic controller
下载PDF
A Data Driven Security Correction Method for Power Systems with UPFC 被引量:1
4
作者 Qun Li Ningyu Zhang +2 位作者 Jianhua Zhou Xinyao Zhu Peng Li 《Energy Engineering》 EI 2023年第6期1485-1502,共18页
The access of unified power flow controllers(UPFC)has changed the structure and operation mode of power grids all across the world,and it has brought severe challenges to the traditional real-time calculation of secur... The access of unified power flow controllers(UPFC)has changed the structure and operation mode of power grids all across the world,and it has brought severe challenges to the traditional real-time calculation of security correction based on traditionalmodels.Considering the limitation of computational efficiency regarding complex,physical models,a data-driven power system security correction method with UPFC is,in this paper,proposed.Based on the complex mapping relationship between the operation state data and the security correction strategy,a two-stage deep neural network(DNN)learning framework is proposed,which divides the offline training task of security correction into two stages:in the first stage,the stacked auto-encoder(SAE)classification model is established,and the node correction state(0/1)output based on the fault information;in the second stage,the DNN learningmodel is established,and the correction amount of each action node is obtained based on the action nodes output in the previous stage.In this paper,the UPFC demonstration project of NanjingWest Ring Network is taken as a case study to validate the proposed method.The results show that the proposed method can fully meet the real-time security correction time requirements of power grids,and avoid the inherent defects of the traditional model method without an iterative solution and can also provide reasonable security correction strategies for N-1 and N-2 faults. 展开更多
关键词 MANUSCRIPT security correction data-driven deep neural network(DNN) unified power flow controller(UPFC) overload of transmission lines
下载PDF
A multi-objective gravitational search algorithm based approach of power system stability enhancement with UPFC 被引量:6
5
作者 Ajami Ali Armaghan Mehdi 《Journal of Central South University》 SCIE EI CAS 2013年第6期1536-1544,共9页
On the basis of the theoretical analysis of a single-machine infinite-bus (SMIB), using the modified linearized Phil- lips-Heffron model installed with unified power flow controller (UPFC), the potential of the UP... On the basis of the theoretical analysis of a single-machine infinite-bus (SMIB), using the modified linearized Phil- lips-Heffron model installed with unified power flow controller (UPFC), the potential of the UPFC supplementary controller to enhance the dynamic stability of a power system is evaluated by measuring the electromechanical controllability through singular value decomposition (SVD) analysis. This controller is tuned to simultaneously shift the undamped electromeehanical modes to a prescribed zone in the s-plane. The problem of robust UPFC based damping controller is formulated as an optimization problem according to the eigenvalue-based multi-objective function comprising the damping factor, and the damping ratio of the undamped electromechanical modes to be solved using gravitational search algorithm (GSA) that has a strong ability to find the most optimistic results. The different loading conditions are simulated on a SMIB system and the rotor speed deviation, internal voltage deviation, DC voltage deviation and electrical power deviation responses are studied with the effect of this flexible AC transmission systems (FACTS) controller. The results reveal that the tuned GSA based UPFC controller using the proposed multi-objective function has an excellent capability in damping power system with low frequency oscillations and greatly enhances the dynamic stability of the power systems. 展开更多
关键词 unified power flow controller gravitational search algorithm power system stability
下载PDF
UPFC setting to avoid active power flow loop considering wind power uncertainty
6
作者 Shenghu LI Ting WANG 《Frontiers in Energy》 SCIE CSCD 2023年第1期165-175,共11页
The active power loop flow(APLF)may be caused by impropriate network configuration,impropriate parameter settings,and/or stochastic bus powers.The power flow controllers,e.g.,the unified power flow controller(UPFC),ma... The active power loop flow(APLF)may be caused by impropriate network configuration,impropriate parameter settings,and/or stochastic bus powers.The power flow controllers,e.g.,the unified power flow controller(UPFC),may be the reason and the solution to the loop flows.In this paper,the critical existence condition of the APLF is newly integrated into the simultaneous power flow model for the system and UPFC.Compared with the existing method of alternatively solving the simultaneous power flow and sensitivity-based approaching to the critical existing condition,the integrated power flow needs less iterations and calculation time.Besides,with wind power fluctuation,the interval power flow(IPF)is introduced into the integrated power flow,and solved with the affine Krawcyzk iteration to make sure that the range of active power setting of the UPFC not yielding the APLF.Compared with Monte Carlo simulation,the IPF has the similar accuracy but less time. 展开更多
关键词 active power loop flow(APLF) unified power flow controller(UPFC) wind power uncertainty interval power flow(IPF)
原文传递
Machine Learning for Hybrid Line Stability Ranking Index in Polynomial Load Modeling under Contingency Conditions
7
作者 P.Venkatesh N.Visali 《Intelligent Automation & Soft Computing》 SCIE 2023年第7期1001-1012,共12页
In the conventional technique,in the evaluation of the severity index,clustering and loading suffer from more iteration leading to more com-putational delay.Hence this research article identifies,a novel progression f... In the conventional technique,in the evaluation of the severity index,clustering and loading suffer from more iteration leading to more com-putational delay.Hence this research article identifies,a novel progression for fast predicting the severity of the line and clustering by incorporating machine learning aspects.The polynomial load modelling or ZIP(constant impedances(Z),Constant Current(I)and Constant active power(P))is developed in the IEEE-14 and Indian 118 bus systems considered for analysis of power system security.The process of finding the severity of the line using a Hybrid Line Stability Ranking Index(HLSRI)is used for assisting the concepts of machine learning with J48 algorithm,infers the superior affected lines by adopting the IEEE standards in concern to be compensated in maintaining the power system stability.The simulation is performed in the WEKA environment and deals with the supervisor learning in order based on severity to ensure the safety of power system.The Unified Power Flow Controller(UPFC),facts devices for the purpose of compensating the losses by maintaining the voltage characteristics.The finite element analysis findings are compared with the existing procedures and numerical equations for authentications. 展开更多
关键词 CONTINGENCY hybrid line stability ranking index(HLSRI) machine learning(ML) unified power flow controller(UPFC) ZIP load modelling
下载PDF
Evaluation of optimal UPFC allocation for improving transmission capacity 被引量:1
8
作者 Xuhui Shen Hongmei Luo +2 位作者 Wenman Gao Yuyao Feng Nan Feng 《Global Energy Interconnection》 2020年第3期217-226,共10页
A unified power flow controller(UPFC)combines the advantages of various flexible alternating current transmission system(FACTS)devices into a powerful format.Using a 500 kV power grid,this study evaluates the selectio... A unified power flow controller(UPFC)combines the advantages of various flexible alternating current transmission system(FACTS)devices into a powerful format.Using a 500 kV power grid,this study evaluates the selection and use of a UPFC to improve transmission capacity.The"UPFC unit capacity control proportionality coefficient"is introduced to quantify the control effect of the UPFC,and an optimal calculation method for the UPFC capacity is presented.Following the proposal of a UPFC site selection process,the data of an existing power grid is used to conduct simulations.The simulation results show that the UPFC has a strong ability to improve transmission capacity,and its use is greatly advantageous.Additionally,by applying the proposed selection method,the control effect and economic benefits of the UPFC can be comprehensively considered during project site selection.These findings have a guiding significance for UPFC site selection in ultra-high voltage power grids. 展开更多
关键词 unified power flow controller UPFC unit capacity control proportionality coefficient UHV power grid Transmission capability Optimal capacity calculation UPFC site selection
下载PDF
Adaptive fractional integral terminal sliding mode power control of UPFC in DFIG wind farm penetrated multimachine power system 被引量:6
9
作者 P.K.Dash R.K.Patnaik S.P.Mishra 《Protection and Control of Modern Power Systems》 2018年第1期79-92,共14页
With an aim to improve the transient stability of a DFIG wind farm penetrated multimachine power system(MPN),an adaptive fractional integral terminal sliding mode power control(AFITSMPC)strategy has been proposed for ... With an aim to improve the transient stability of a DFIG wind farm penetrated multimachine power system(MPN),an adaptive fractional integral terminal sliding mode power control(AFITSMPC)strategy has been proposed for the unified power flow controller(UPFC),which is compensating the MPN.The proposed AFITSMPC controls the dq-axis series injected voltage,which controls the admittance model(AM)of the UPFC.As a result the power output of the DFIG stabilizes which helps in maintaining the equilibrium between the electrical and mechanical power of the nearby generators.Subsequently the rotor angular deviation of the respective generators gets recovered,which significantly stabilizes the MPN.The proposed AFITSMPC for the admittance model of the UPFC has been validated in a DFIG wind farm penetrated 2 area 4 machine power system in the MATLAB environment.The robustness and efficacy of the proposed control strategy of the UPFC,in contrast to the conventional PI control is vindicated under a number of intrinsic operating conditions,and the results analyzed are satisfactory. 展开更多
关键词 Adaptive fractional integral terminal sliding mode power control Doubly fed induction generator Multimachine power network unified power flow controller
原文传递
Security-constrained line loss minimization in distribution systems with high penetration of renewable energy using UPFC 被引量:9
10
作者 Pengcheng SONG Zheng XU +2 位作者 Huanfeng DONG Hui CAI Zhenjian XIE 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2017年第6期876-886,共11页
Focused on the challenges raised by the largescale integration of renewable energy resources and the urgent goal of energy saving,a novel control scheme for the unified power flow controller(UPFC)series converter is p... Focused on the challenges raised by the largescale integration of renewable energy resources and the urgent goal of energy saving,a novel control scheme for the unified power flow controller(UPFC)series converter is proposed to achieve line loss reduction and security enhancement in distribution systems with a high penetration of renewable energy.Firstly,the line loss minimum conditions of a general distribution system with loop configurations are deduced.Secondly,security constraints including the permissible voltage range,the line loading limits and the UPFC ratings are considered.System security enhancement with the least increase in line loss is tackled by solving a much reduced optimal power flow(OPF)problem.The computational task of the OPF problem is reduced by deducing the security-constrained line loss minimum conditions and removing the equality constraints.Thirdly,a hybrid control scheme is proposed.Line loss minimization is achieved through a dynamic controller,while an OPF calculator is integrated to generate corrective action for the dynamic controller when the security constraints are violated.The validity of the proposed control strategies is verified in a modified IEEE 33 bus test system. 展开更多
关键词 Line loss minimization Security enhancement unified power flow controller(UPFC) Renewable energy
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部