AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants ...AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants underwent ICL surgery and were divided into the low(<250μm)and normal(250-1000μm)vault groups based on the postoperative vault at 3mo.The preoperative biometric parameters and clinical outcomes were compared between the two groups.The relationship between the 3-month vault values and preoperative ocular parameters were evaluated by Generalized estimating equations.RESULTS:Sixteen(23 eyes)and 36 patients(63 eyes)were in the low and normal vault groups,respectively.All implantation procedures were uneventful with no cataract formation in the early postoperative period.The sulcusto-sulcus lens rise(STSL)and iris ciliary angle(ICA)were correlated with vault at 3mo after surgery.Every 0.1 mm increase in STSL was associated with 38.9μm decrease in the postoperative 3-month vault.A rise of 1 degree in ICA is associated with a reduction of 4μm in vault.CONCLUSION:Eyes with a narrow ciliary sulcus are associated with a higher rate of low vault after ICL implantation,suggesting a need for adjustments to the ICL size in these patients.Evaluating the characteristics of the ciliary sulcus contributes valuable information to predict low vault after surgery.展开更多
AIM:To analyze ultrasound biomicroscopy(UBM)images using random forest network to find new features to make predictions about vault after implantable collamer lens(ICL)implantation.METHODS:A total of 450 UBM images we...AIM:To analyze ultrasound biomicroscopy(UBM)images using random forest network to find new features to make predictions about vault after implantable collamer lens(ICL)implantation.METHODS:A total of 450 UBM images were collected from the Lixiang Eye Hospital to provide the patient’s preoperative parameters as well as the vault of the ICL after implantation.The vault was set as the prediction target,and the input elements were mainly ciliary sulcus shape parameters,which included 6 angular parameters,2 area parameters,and 2 parameters,distance between ciliary sulci,and anterior chamber height.A random forest regression model was applied to predict the vault,with the number of base estimators(n_estimators)of 2000,the maximum tree depth(max_depth)of 17,the number of tree features(max_features)of Auto,and the random state(random_state)of 40.0.RESULTS:Among the parameters selected in this study,the distance between ciliary sulci had a greater importance proportion,reaching 52%before parameter optimization is performed,and other features had less influence,with an importance proportion of about 5%.The importance of the distance between the ciliary sulci increased to 53% after parameter optimization,and the importance of angle 3 and area 1 increased to 5% and 8%respectively,while the importance of the other parameters remained unchanged,and the distance between the ciliary sulci was considered the most important feature.Other features,although they accounted for a relatively small proportion,also had an impact on the vault prediction.After parameter optimization,the best prediction results were obtained,with a predicted mean value of 763.688μm and an actual mean value of 776.9304μm.The R²was 0.4456 and the root mean square error was 201.5166.CONCLUSION:A study based on UBM images using random forest network can be performed for prediction of the vault after ICL implantation and can provide some reference for ICL size selection.展开更多
Dear Editor,We are writing this letter to report two unusual cases of femtosecond laser-assisted cataract surgery(FLACS)in two ICL-implanted patients with significant different vault.FLACS has been confirmed by accumu...Dear Editor,We are writing this letter to report two unusual cases of femtosecond laser-assisted cataract surgery(FLACS)in two ICL-implanted patients with significant different vault.FLACS has been confirmed by accumulating evidence to improve the safety and precision of surgery from common cases to complicated cases in treating cataracts[1-3].Implantable collamer lens(ICL)implantation possesses a good performance in its predictability,reversibility,and the rapid visual recovery.展开更多
The bone defects of the cranial vault encompassed rare malformations including acalvaria, hypocalvaria, acrania, hypocrania, anencephaly and exencephaly. They are also described in some pathological entities such as a...The bone defects of the cranial vault encompassed rare malformations including acalvaria, hypocalvaria, acrania, hypocrania, anencephaly and exencephaly. They are also described in some pathological entities such as aplasia cutis congenita of the scalp. We report an unusual case of cephalic malformation which combine defects of the skin, the dura mater, and the bones of the vault, with a malformation of the central nervous system. This unique case emphasizes a problem of nosological definition between the terms mentioned above. acalvaria, the acrania, the hypocalvaria and the aplasia cutis congenita. Thus, herein, we proceed to a literature review of bone defects of the skull and their differential diagnosis.展开更多
This letter proposes fingerprint-based key binding/recovering with fuzzy vault. Fingerprint minutiae data and the cryptographic key are merged together by a multivariable linear function. First, the minutiae data are ...This letter proposes fingerprint-based key binding/recovering with fuzzy vault. Fingerprint minutiae data and the cryptographic key are merged together by a multivariable linear function. First, the minutiae data are bound by a set of random data through the linear function. The number of the function’s variables is determined by the required number of matched minutiae. Then, a new key de- rived from the random data is used to encrypt the cryptographic key. Lastly, the binding data are protected using fuzzy vault scheme. The proposed scheme provides the system with the flexibility to use changeable number of minutiae to bind/recover the protected key and a unified method regardless of the length of the key.展开更多
Recently, a cryptographic construct,called fuzzy vault, has been proposed for crypto-biometric systems, and some implementations for fingerprint have been reported to protect the stored fingerprint template by hiding ...Recently, a cryptographic construct,called fuzzy vault, has been proposed for crypto-biometric systems, and some implementations for fingerprint have been reported to protect the stored fingerprint template by hiding the fingerprint features. However, all previous studies assumed that fingerprint features were pre-aligned, and automatic alignment in the fuzzy vault domain is a challenging issue.In this paper, an auto-aligned sharing fuzzy fingerprint vault based on a geometric hashing technique is proposed to address automatic alignment in the multiple-control fuzzy vault with a compartmented structure. The vulnerability analysis and experimental results indicate that, compared with original multiplecontrol fuzzy vault, the auto-aligned sharing fuzzy fingerprint vault can improve the security of the system.展开更多
This study aimed to investigate the difference in gait regulation strategy of pole vault approach runs between successful and failed trials. Five male junior pole vaulters completed full vaulting to 90%-95% personal b...This study aimed to investigate the difference in gait regulation strategy of pole vault approach runs between successful and failed trials. Five male junior pole vaulters completed full vaulting to 90%-95% personal best height. These trials were categorized into successful and failed trials. Step length and the distance from toe to the planting box were obtained using a two dimensional direct linear transformation procedure. In successful trials, standard deviations of the toe-box distance (SDTB) at the last step and take-off of were significantly smaller than those of failed trials (P 〈 0.05). We observed a clear difference in gait regulation strategy between successful and failed trials, thereby suggesting that to minimize the fluctuations of the toe-box distance immediately before the take-off is a key gait regulation strategy for successful pole vault performance.展开更多
Hysterectomy is common major operation performed in gynecological field practice after Caesarean section. Vaginal hysterectomy is preferred surgery for uterovaginal prolapsed. Vaginal hysterectomy has advantages over ...Hysterectomy is common major operation performed in gynecological field practice after Caesarean section. Vaginal hysterectomy is preferred surgery for uterovaginal prolapsed. Vaginal hysterectomy has advantages over abdominal hysterectomy. Post hysterectomy hematomas are responsible for serious morbidity. Ultrasound is an accurate diagnostic tool and so Computed tomography. Conservative management, analgesia and antibiotics will work in small hematoma, but the significant sized hematoma needs surgical drainage and the infected hematoma. Refinement in surgical techniques is recommended to minimize the formation vaginal vault hematomas after vaginal hysterectomy.展开更多
基金Supported by National Natural Science Foundation of China(No.81900910)Natural Science Foundation of Zhejiang Province(No.LQ19H120003)Basic Scientific Research Project of Wenzhou(No.Y2023809).
文摘AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants underwent ICL surgery and were divided into the low(<250μm)and normal(250-1000μm)vault groups based on the postoperative vault at 3mo.The preoperative biometric parameters and clinical outcomes were compared between the two groups.The relationship between the 3-month vault values and preoperative ocular parameters were evaluated by Generalized estimating equations.RESULTS:Sixteen(23 eyes)and 36 patients(63 eyes)were in the low and normal vault groups,respectively.All implantation procedures were uneventful with no cataract formation in the early postoperative period.The sulcusto-sulcus lens rise(STSL)and iris ciliary angle(ICA)were correlated with vault at 3mo after surgery.Every 0.1 mm increase in STSL was associated with 38.9μm decrease in the postoperative 3-month vault.A rise of 1 degree in ICA is associated with a reduction of 4μm in vault.CONCLUSION:Eyes with a narrow ciliary sulcus are associated with a higher rate of low vault after ICL implantation,suggesting a need for adjustments to the ICL size in these patients.Evaluating the characteristics of the ciliary sulcus contributes valuable information to predict low vault after surgery.
文摘AIM:To analyze ultrasound biomicroscopy(UBM)images using random forest network to find new features to make predictions about vault after implantable collamer lens(ICL)implantation.METHODS:A total of 450 UBM images were collected from the Lixiang Eye Hospital to provide the patient’s preoperative parameters as well as the vault of the ICL after implantation.The vault was set as the prediction target,and the input elements were mainly ciliary sulcus shape parameters,which included 6 angular parameters,2 area parameters,and 2 parameters,distance between ciliary sulci,and anterior chamber height.A random forest regression model was applied to predict the vault,with the number of base estimators(n_estimators)of 2000,the maximum tree depth(max_depth)of 17,the number of tree features(max_features)of Auto,and the random state(random_state)of 40.0.RESULTS:Among the parameters selected in this study,the distance between ciliary sulci had a greater importance proportion,reaching 52%before parameter optimization is performed,and other features had less influence,with an importance proportion of about 5%.The importance of the distance between the ciliary sulci increased to 53% after parameter optimization,and the importance of angle 3 and area 1 increased to 5% and 8%respectively,while the importance of the other parameters remained unchanged,and the distance between the ciliary sulci was considered the most important feature.Other features,although they accounted for a relatively small proportion,also had an impact on the vault prediction.After parameter optimization,the best prediction results were obtained,with a predicted mean value of 763.688μm and an actual mean value of 776.9304μm.The R²was 0.4456 and the root mean square error was 201.5166.CONCLUSION:A study based on UBM images using random forest network can be performed for prediction of the vault after ICL implantation and can provide some reference for ICL size selection.
基金Supported by Key Research and Development Program of Shaanxi Province(No.2020SF-271,No.2017SF-273)。
文摘Dear Editor,We are writing this letter to report two unusual cases of femtosecond laser-assisted cataract surgery(FLACS)in two ICL-implanted patients with significant different vault.FLACS has been confirmed by accumulating evidence to improve the safety and precision of surgery from common cases to complicated cases in treating cataracts[1-3].Implantable collamer lens(ICL)implantation possesses a good performance in its predictability,reversibility,and the rapid visual recovery.
文摘The bone defects of the cranial vault encompassed rare malformations including acalvaria, hypocalvaria, acrania, hypocrania, anencephaly and exencephaly. They are also described in some pathological entities such as aplasia cutis congenita of the scalp. We report an unusual case of cephalic malformation which combine defects of the skin, the dura mater, and the bones of the vault, with a malformation of the central nervous system. This unique case emphasizes a problem of nosological definition between the terms mentioned above. acalvaria, the acrania, the hypocalvaria and the aplasia cutis congenita. Thus, herein, we proceed to a literature review of bone defects of the skull and their differential diagnosis.
基金Supported by the National Natural Science Foundation of China (No.60472069)
文摘This letter proposes fingerprint-based key binding/recovering with fuzzy vault. Fingerprint minutiae data and the cryptographic key are merged together by a multivariable linear function. First, the minutiae data are bound by a set of random data through the linear function. The number of the function’s variables is determined by the required number of matched minutiae. Then, a new key de- rived from the random data is used to encrypt the cryptographic key. Lastly, the binding data are protected using fuzzy vault scheme. The proposed scheme provides the system with the flexibility to use changeable number of minutiae to bind/recover the protected key and a unified method regardless of the length of the key.
文摘Recently, a cryptographic construct,called fuzzy vault, has been proposed for crypto-biometric systems, and some implementations for fingerprint have been reported to protect the stored fingerprint template by hiding the fingerprint features. However, all previous studies assumed that fingerprint features were pre-aligned, and automatic alignment in the fuzzy vault domain is a challenging issue.In this paper, an auto-aligned sharing fuzzy fingerprint vault based on a geometric hashing technique is proposed to address automatic alignment in the multiple-control fuzzy vault with a compartmented structure. The vulnerability analysis and experimental results indicate that, compared with original multiplecontrol fuzzy vault, the auto-aligned sharing fuzzy fingerprint vault can improve the security of the system.
文摘This study aimed to investigate the difference in gait regulation strategy of pole vault approach runs between successful and failed trials. Five male junior pole vaulters completed full vaulting to 90%-95% personal best height. These trials were categorized into successful and failed trials. Step length and the distance from toe to the planting box were obtained using a two dimensional direct linear transformation procedure. In successful trials, standard deviations of the toe-box distance (SDTB) at the last step and take-off of were significantly smaller than those of failed trials (P 〈 0.05). We observed a clear difference in gait regulation strategy between successful and failed trials, thereby suggesting that to minimize the fluctuations of the toe-box distance immediately before the take-off is a key gait regulation strategy for successful pole vault performance.
文摘Hysterectomy is common major operation performed in gynecological field practice after Caesarean section. Vaginal hysterectomy is preferred surgery for uterovaginal prolapsed. Vaginal hysterectomy has advantages over abdominal hysterectomy. Post hysterectomy hematomas are responsible for serious morbidity. Ultrasound is an accurate diagnostic tool and so Computed tomography. Conservative management, analgesia and antibiotics will work in small hematoma, but the significant sized hematoma needs surgical drainage and the infected hematoma. Refinement in surgical techniques is recommended to minimize the formation vaginal vault hematomas after vaginal hysterectomy.