The fabrication and characterization of p-i-n photodiodes integrated with wide spectrum focusing reflectors using nonperiodic strip and concentric-circular subwavelength gratings are presented. The experimental result...The fabrication and characterization of p-i-n photodiodes integrated with wide spectrum focusing reflectors using nonperiodic strip and concentric-circular subwavelength gratings are presented. The experimental results show that the gratings can reflect and focus the incident light on the absorber of the photodiode, and thus can simultaneously achieve high speed and high efficiency. For the gratings’ integrated photodiodes, the responsivity is improved over a wide spectral range, and when the absorber was 600 nm and the mesa diameter was40 μm, a responsivity of 0.46 A/W at a wavelength of 1.55 μm and a 3 dB bandwidth of 21.6 GHz under a reverse bias of 3 V were simultaneously obtained.展开更多
In array signal processing, 2-D spatial-spectrum estimation is required to determine DOA of multiple signals. The circular array of sensors is found to possess several nice properties for DOA estimation of wide-band s...In array signal processing, 2-D spatial-spectrum estimation is required to determine DOA of multiple signals. The circular array of sensors is found to possess several nice properties for DOA estimation of wide-band sources. C. U. Padmini, et al.(1994) had suggested that the frequency-direction ambiguity in azimuth estimation of wide-baud signals received by a uniform linear array (ULA) can be avoided by using a circular array, even without the use of any delay elements. In 2-D spatial-spectrum estimation for wide-band signals, the authors find that it is impossible to avoid the ambiguity in source frequency-elevation angle pairs using a circular array. In this paper, interpolated circular arrays are used to perform 2-D spatial-spectrum estimation for wide-band sources. In the estimation, a large aperture circular array (Υ】λmin/2) is found to possess superior resolution capability and robustness.展开更多
Simultaneous development of well impedance matching and strong loss capability has become a mainstream method for achieving outstanding electromagnetic microwave absorption(EMWA)performances over wide temperature rang...Simultaneous development of well impedance matching and strong loss capability has become a mainstream method for achieving outstanding electromagnetic microwave absorption(EMWA)performances over wide temperature range.However,it is difficult to pursue both due to the mutual restraint of relationship between impedance matching and loss capability about temperature.Here,we propose a flexible regulation engineering of titanium nitride(TiN)nanofibrous membranes(NMs,TNMs),which could be distributed uniformly in the polydimethylsiloxane(PDMS)matrix and contributed to the formation of abundant local conductive networks,generating the local conductive loss and enhancing the loss ability of EMWs.Moreover,when the TNMs are used as functional units and dispersed in the matrix,the corresponding composites exhibit an outstanding anti-reflection effect on microwaves.As hoped,under the precondition of good impedance matching,local conductive loss and polarization loss together improve the loss capacity at room temperature,and polarization loss can compensate the local conductive loss to acquire effective dielectric response at elevated temperature.Benefiting from the reasonably synergistic loss ability caused by flexible regulation engineering,the corresponding composites exhibit the perfect EMWA performances in a wide temperature range from 298 to 573 K.This work not only elaborates the ponderable insights of independent membrane in the composition-structure-function connection,but also provides a feasible tactic for resolving coexistence of well impedance matching and strong loss capability issues in wide temperature spectrum.展开更多
光轴一致性是衡量多传感器光电系统工作性能的重要指标,为了解决多传感器轴一致性检测系统工作波段范围较窄、系统灵活性较低的问题,本文结合光路切换和光热转换的思想,设计了一套宽光谱多传感器轴一致性检测系统。该系统采用卡塞格林...光轴一致性是衡量多传感器光电系统工作性能的重要指标,为了解决多传感器轴一致性检测系统工作波段范围较窄、系统灵活性较低的问题,本文结合光路切换和光热转换的思想,设计了一套宽光谱多传感器轴一致性检测系统。该系统采用卡塞格林反射式光学系统作为从可见光到长波红外范围内的接收和发射系统;通过步进电机的驱动,带动导轨上方反光镜位置移动,实现系统光路的切换;采用镀有硫化铜的锗玻璃,作为光热转换靶材,将短波长的光斑转换为热斑,采用长波红外探测器实现对各波段激光光斑图像采集。系统能够实现0.4~14μm波段光谱范围的检测;对光学系统进行像质评价分析,可以得到系统在不同波段下由像差引起的弥散斑(Root mean square,RMS)直径均在9μm以下,能量集中度较好;对系统检测精度进行分析,最大测量误差为0.1 mrad;通过导轨往返运动重复精度实验和系统测量准确度实验,对系统可靠性进行验证,结果表明检测系统满足仪表准确度1.5级的要求。该检测系统结构紧凑,适用波谱范围广,能够实现对多传感器光电设备的轴一致性检测。展开更多
Extended light absorption and dynamic charge separation are vital factors that determine the effectivenessof photocatalysts.In this study,a nonmetallic plasmonic S‐scheme photocatalyst was fabricatedby loading 1D pla...Extended light absorption and dynamic charge separation are vital factors that determine the effectivenessof photocatalysts.In this study,a nonmetallic plasmonic S‐scheme photocatalyst was fabricatedby loading 1D plasmonic W_(18)O_(49)nanowires onto 2D g‐C_(3)N_(4)nanosheets.W_(18)O_(49)nanowiresplay the dual role of a light absorption antenna—that extends light adsorption—and a hot electrondonor—that assists the water reduction reaction in a wider light spectrum range.Moreover,S‐scheme charge transfer resulting from the matching bandgaps of W_(18)O_(49)and g‐C_(3)N_(4)can lead tostrong redox capability and high migration speed of the photoinduced charges.Consequently,in thisstudy,W_(18)O_(49)/g‐C_(3)N_(4)hybrids exhibited higher photocatalytic H2 generation than that of pristineg‐C_(3)N_(4)under light irradiation of 420–550 nm.Furthermore,the H2 production rate of thebest‐performing W_(18)O_(49)/g‐C_(3)N_(4)hybrid was 41.5μmol·g^(−1)·h^(−1)upon exposure to monochromaticlight at 550 nm,whereas pure g‐C_(3)N_(4)showed negligible activity.This study promotes novel andenvironmentally friendly hot‐electron‐assisted S‐scheme photocatalysts for the broad‐spectrumutilization of solar light.展开更多
In this paper, a fast algorithm to reconstruct the spectrum of non-uniformly sampled signals is proposed. Compared with the original algorithm, the fast algorithm has a higher computational efficiency, especially when...In this paper, a fast algorithm to reconstruct the spectrum of non-uniformly sampled signals is proposed. Compared with the original algorithm, the fast algorithm has a higher computational efficiency, especially when sampling sequence is long. Particularly, a transformation matrix is built, and the reconstructed spectrum is perfectly synthesized from the spectrum of every sampling channel. The fast algorithm has solved efficiency issues of spectrum reconstruction algorithm, and making it possible for the actual application of spectrum reconstruction algorithm in multi-channel Synthetic Aperture Radar (SAR).展开更多
基金funded by the National Natural Science Foundation of China(NSFC)(Nos.61574019,61674020,and 61274044)the 111 Project(No.B07005)+2 种基金the Beijing Municipality Natural Science Foundation(No.4132069)the Program for Changjiang ScholarsInnovative Research Team in University through the Ministry of Education of China(No.IRT0609)
文摘The fabrication and characterization of p-i-n photodiodes integrated with wide spectrum focusing reflectors using nonperiodic strip and concentric-circular subwavelength gratings are presented. The experimental results show that the gratings can reflect and focus the incident light on the absorber of the photodiode, and thus can simultaneously achieve high speed and high efficiency. For the gratings’ integrated photodiodes, the responsivity is improved over a wide spectral range, and when the absorber was 600 nm and the mesa diameter was40 μm, a responsivity of 0.46 A/W at a wavelength of 1.55 μm and a 3 dB bandwidth of 21.6 GHz under a reverse bias of 3 V were simultaneously obtained.
文摘In array signal processing, 2-D spatial-spectrum estimation is required to determine DOA of multiple signals. The circular array of sensors is found to possess several nice properties for DOA estimation of wide-band sources. C. U. Padmini, et al.(1994) had suggested that the frequency-direction ambiguity in azimuth estimation of wide-baud signals received by a uniform linear array (ULA) can be avoided by using a circular array, even without the use of any delay elements. In 2-D spatial-spectrum estimation for wide-band signals, the authors find that it is impossible to avoid the ambiguity in source frequency-elevation angle pairs using a circular array. In this paper, interpolated circular arrays are used to perform 2-D spatial-spectrum estimation for wide-band sources. In the estimation, a large aperture circular array (Υ】λmin/2) is found to possess superior resolution capability and robustness.
基金support of the National Natural Science Foundation of China(Nos.22305066 and U1704253).
文摘Simultaneous development of well impedance matching and strong loss capability has become a mainstream method for achieving outstanding electromagnetic microwave absorption(EMWA)performances over wide temperature range.However,it is difficult to pursue both due to the mutual restraint of relationship between impedance matching and loss capability about temperature.Here,we propose a flexible regulation engineering of titanium nitride(TiN)nanofibrous membranes(NMs,TNMs),which could be distributed uniformly in the polydimethylsiloxane(PDMS)matrix and contributed to the formation of abundant local conductive networks,generating the local conductive loss and enhancing the loss ability of EMWs.Moreover,when the TNMs are used as functional units and dispersed in the matrix,the corresponding composites exhibit an outstanding anti-reflection effect on microwaves.As hoped,under the precondition of good impedance matching,local conductive loss and polarization loss together improve the loss capacity at room temperature,and polarization loss can compensate the local conductive loss to acquire effective dielectric response at elevated temperature.Benefiting from the reasonably synergistic loss ability caused by flexible regulation engineering,the corresponding composites exhibit the perfect EMWA performances in a wide temperature range from 298 to 573 K.This work not only elaborates the ponderable insights of independent membrane in the composition-structure-function connection,but also provides a feasible tactic for resolving coexistence of well impedance matching and strong loss capability issues in wide temperature spectrum.
文摘光轴一致性是衡量多传感器光电系统工作性能的重要指标,为了解决多传感器轴一致性检测系统工作波段范围较窄、系统灵活性较低的问题,本文结合光路切换和光热转换的思想,设计了一套宽光谱多传感器轴一致性检测系统。该系统采用卡塞格林反射式光学系统作为从可见光到长波红外范围内的接收和发射系统;通过步进电机的驱动,带动导轨上方反光镜位置移动,实现系统光路的切换;采用镀有硫化铜的锗玻璃,作为光热转换靶材,将短波长的光斑转换为热斑,采用长波红外探测器实现对各波段激光光斑图像采集。系统能够实现0.4~14μm波段光谱范围的检测;对光学系统进行像质评价分析,可以得到系统在不同波段下由像差引起的弥散斑(Root mean square,RMS)直径均在9μm以下,能量集中度较好;对系统检测精度进行分析,最大测量误差为0.1 mrad;通过导轨往返运动重复精度实验和系统测量准确度实验,对系统可靠性进行验证,结果表明检测系统满足仪表准确度1.5级的要求。该检测系统结构紧凑,适用波谱范围广,能够实现对多传感器光电设备的轴一致性检测。
文摘Extended light absorption and dynamic charge separation are vital factors that determine the effectivenessof photocatalysts.In this study,a nonmetallic plasmonic S‐scheme photocatalyst was fabricatedby loading 1D plasmonic W_(18)O_(49)nanowires onto 2D g‐C_(3)N_(4)nanosheets.W_(18)O_(49)nanowiresplay the dual role of a light absorption antenna—that extends light adsorption—and a hot electrondonor—that assists the water reduction reaction in a wider light spectrum range.Moreover,S‐scheme charge transfer resulting from the matching bandgaps of W_(18)O_(49)and g‐C_(3)N_(4)can lead tostrong redox capability and high migration speed of the photoinduced charges.Consequently,in thisstudy,W_(18)O_(49)/g‐C_(3)N_(4)hybrids exhibited higher photocatalytic H2 generation than that of pristineg‐C_(3)N_(4)under light irradiation of 420–550 nm.Furthermore,the H2 production rate of thebest‐performing W_(18)O_(49)/g‐C_(3)N_(4)hybrid was 41.5μmol·g^(−1)·h^(−1)upon exposure to monochromaticlight at 550 nm,whereas pure g‐C_(3)N_(4)showed negligible activity.This study promotes novel andenvironmentally friendly hot‐electron‐assisted S‐scheme photocatalysts for the broad‐spectrumutilization of solar light.
文摘In this paper, a fast algorithm to reconstruct the spectrum of non-uniformly sampled signals is proposed. Compared with the original algorithm, the fast algorithm has a higher computational efficiency, especially when sampling sequence is long. Particularly, a transformation matrix is built, and the reconstructed spectrum is perfectly synthesized from the spectrum of every sampling channel. The fast algorithm has solved efficiency issues of spectrum reconstruction algorithm, and making it possible for the actual application of spectrum reconstruction algorithm in multi-channel Synthetic Aperture Radar (SAR).