This paper proposes a PMU (phasor measurement unit) based monitoring and estimation scheme of power system small-signal stability in Singapore-Malaysia interconnection power system through a 50-Hz and 500 kV transmi...This paper proposes a PMU (phasor measurement unit) based monitoring and estimation scheme of power system small-signal stability in Singapore-Malaysia interconnection power system through a 50-Hz and 500 kV transmission line. Two PMUs are installed in the power system interconnection network of Singapore-Malaysia. One PMU is located in Singapore and the other one in Malaysia (Penang). Both PMUs measure the single-phase voltage phasor. The data filtering technique based on FFT (Fast Fourier Transform) is employed to extract oscillation data for single mode. Finally, some analysis results of monitoring and estimation of Singapore-Malaysia interconnected power system based on application practice of the CampusWAMS are presented and analyzed.展开更多
This study presents the assumptions and strategies for the practical implementation of the dynamic mode decomposition approach in the wide-area monitoring system of the Italian transmission system operator,Terna.The p...This study presents the assumptions and strategies for the practical implementation of the dynamic mode decomposition approach in the wide-area monitoring system of the Italian transmission system operator,Terna.The procedure setup aims to detect poorly damped interarea oscillations of power systems.Dynamic mode decomposition is a data-driven technique that has gained increasing attention in different fields;the proposed implementation can both characterize the oscillatory modes and identify the most influenced areas.This study presents the results of its practical implementation and operational experience in power system monitoring.It focuses on the main characteristics and solutions identified to reliably monitor the interarea electromechanical modes of the interconnected European power system.Moreover,conditions to issue an appropriate alarm in case of critical operating conditions are described.The effectiveness of the proposed approach is validated by its application in three case studies:a critical oscillatory event and a short-circuit event that occurred in the Italian power system in the previous years,and a 15-min time interval of normal grid operation recorded in March 2021.展开更多
文摘This paper proposes a PMU (phasor measurement unit) based monitoring and estimation scheme of power system small-signal stability in Singapore-Malaysia interconnection power system through a 50-Hz and 500 kV transmission line. Two PMUs are installed in the power system interconnection network of Singapore-Malaysia. One PMU is located in Singapore and the other one in Malaysia (Penang). Both PMUs measure the single-phase voltage phasor. The data filtering technique based on FFT (Fast Fourier Transform) is employed to extract oscillation data for single mode. Finally, some analysis results of monitoring and estimation of Singapore-Malaysia interconnected power system based on application practice of the CampusWAMS are presented and analyzed.
文摘This study presents the assumptions and strategies for the practical implementation of the dynamic mode decomposition approach in the wide-area monitoring system of the Italian transmission system operator,Terna.The procedure setup aims to detect poorly damped interarea oscillations of power systems.Dynamic mode decomposition is a data-driven technique that has gained increasing attention in different fields;the proposed implementation can both characterize the oscillatory modes and identify the most influenced areas.This study presents the results of its practical implementation and operational experience in power system monitoring.It focuses on the main characteristics and solutions identified to reliably monitor the interarea electromechanical modes of the interconnected European power system.Moreover,conditions to issue an appropriate alarm in case of critical operating conditions are described.The effectiveness of the proposed approach is validated by its application in three case studies:a critical oscillatory event and a short-circuit event that occurred in the Italian power system in the previous years,and a 15-min time interval of normal grid operation recorded in March 2021.