An in-situ analysis and measurement of thorium-234,uranium isotopes in seawater 被引量:5
1
作者 ZENG Xianzhang QIU Manhua +6 位作者 YINMingduan ZENG Wenyi HE Jianhua WAN Xueguo CHEN Hengliang LI Jing TAN Baozeng 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2007年第3期73-83,共11页
A low-level β counting-or spectrum apparatus used for the detection of the β radiation of thorium-234 and α spectrum of thorium- 228 simultaneously and an easy operating procedure for the enrichment, radiochemical ... A low-level β counting-or spectrum apparatus used for the detection of the β radiation of thorium-234 and α spectrum of thorium- 228 simultaneously and an easy operating procedure for the enrichment, radiochemical separating, sampling and measurement of thorium-234 and uranium-238 in the ocean are developed based on the requirements of analyzing export productivity in the eupho- ric zone via thorium-234 - uranium-238 radioactivity disequilibrium. The detecting efficiency both of 13 and α radiation is higher than 20%. The background of βradiation is less than 0. 5 min ^-1 , and the energy resolution of ct detector is better than 1%. Total recycle ratio of thorium-234 is about 75%. Using the above apparatus and procedure, the radioactivities of dissolved thorium-234 and uranium-238, particle thorium-234 and uranium-238 in seawater of the South China Sea, the Southern Ocean and the Arctic Ocean were analyzed. 展开更多
关键词 OCEAN β counting-or spectrum apparatus radiochemical separating thorium-234 uranium-238
下载PDF
Development of Prototype Neutron Flux Monitor for ITER 被引量:1
2
作者 Yang Jinwei Song Xianying +6 位作者 Zhang Wei Li Xu Lee Wenzhong Wang Shiqing Xiao Gongshan Yang Bo Lu Shuangtong 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第3期2860-2862,共3页
The prototype neutron flux monitor consists of a high purity ^(235)U fission chamber detector and a'blank'detector,which is a fissile material free detector with the same dimension as the fission chamber detec... The prototype neutron flux monitor consists of a high purity ^(235)U fission chamber detector and a'blank'detector,which is a fissile material free detector with the same dimension as the fission chamber detector to identify noise issues such as noise coming from gamma rays.The main parameters of the fission chamber assembly that have been measured in the laboratory are confirmed to approach the technological level of the International Thermonuclear Experimental Reactor(ITER)in the near future.This prototype neutron flux monitor will be further developed to become a neutron flux monitor suitable for the operation phase of D-D fusion on the ITER. 展开更多
关键词 neutron flux monitor fission chamber detector international thermonuclear experimental reactor(ITER) plateau characteristic curve discrimination threshold
下载PDF
Fusion Neutron Flux Monitor for ITER 被引量:1
3
作者 杨进蔚 杨青巍 +3 位作者 肖功珊 张炜 宋先瑛 李旭 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第2期141-147,共7页
Neutron flux monitor (NFM) as an important diagnostic sub-system in ITER (international thermonuclear experimental reactor) provides a global neutron source intensity, fusion power and neutron flux in real time. T... Neutron flux monitor (NFM) as an important diagnostic sub-system in ITER (international thermonuclear experimental reactor) provides a global neutron source intensity, fusion power and neutron flux in real time. Three types of neutron flux monitor assemblies with different sensitivities and shielding materials have been designed. Through MCNP (Mante-Carlo neutral particle transport code) calculations, this extended system of NFM can detect the neutron flux in a range of 10^4 n/(cm^2.s) to 10^14 n/(cm^2.s). It is capable of providing accurate neutron yield measurements for all operational modes encountered in the ITER experiments including the in-situ calibration. Combining both the counting mode and Campbelling (MSV; Mean Square Voltage) mode in the signal processing units, the requirement of the dynamic range (107) for these NFMs and time resolution (1 ms) can be met. Based on a uncertainty analysis, the estimated absolute measurement accuracies of the total fusion neutron yield can reach the required 10% level in both the early stage of the DD-phase and the DD-phase, the absolute measurement accuracy full power DT operation mode. In the advanced would be better than 20%. 展开更多
关键词 neutron flux monitor international thermonuclear experimental reactor(ITER) assembly of fission chamber
下载PDF
Fusion Neutron Flux Detector for the ITER
4
作者 袁国梁 杨青巍 +4 位作者 杨进蔚 宋先瑛 李旭 吴华剑 王志强 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第2期168-171,共4页
Two fission chambers with different amounts of fissile material (enriched 90% uranium-235) have been manufactured for neutron flux detection in a thermonuclear fusion device. The characteristics of neutron signal an... Two fission chambers with different amounts of fissile material (enriched 90% uranium-235) have been manufactured for neutron flux detection in a thermonuclear fusion device. The characteristics of neutron signal and its discrimination from other signals, and a plateau of high voltage between the anode and cathode have been validated in a thermal neutron source. The energy responses of the two fission chambers at seven energy levels have been calibrated in an accelerator fast neutron source and the results agree well with the simulations. 展开更多
关键词 fission chamber fusion neutron flux energy response
下载PDF
Design and construction of the first prototype ionization chamber for CSNS and PA beam loss monitor (BLM) system 被引量:2
5
作者 徐美杭 田建民 +3 位作者 陈昌 陈元柏 徐韬光 陆双桐 《Chinese Physics C》 SCIE CAS CSCD 2009年第2期123-126,共4页
Design and construction of the first prototype ionization chamber for CSNS and Proton Accelerator (PA) beam loss monitor (BLM) system is reported. The low leakage current (〈0.1 pA), good plateau (≈800 V) and... Design and construction of the first prototype ionization chamber for CSNS and Proton Accelerator (PA) beam loss monitor (BLM) system is reported. The low leakage current (〈0.1 pA), good plateau (≈800 V) and linearity range up to 200 Roentgen/h are obtained in the first prototype. All of these give us good experience for further improving the ionization chamber construction. 展开更多
关键词 spallation neutron source proton accelerator beam loss monitor ionization chamber plateau curve LINEARITY
原文传递
Study of the THGEM detector with a reflective CsI photocathode 被引量:2
6
作者 刘宏邦 郑阳恒 +8 位作者 谢一冈 吕军光 周莉 俞伯祥 章爱武 安正华 谢宇广 张东 郑志鹏 《Chinese Physics C》 SCIE CAS CSCD 2011年第4期363-367,共5页
The THGEM detector without and with a CsI has been tested successfully. The optimal parameters of THGEM have been determined from eight samples. The UV photoelectric effect of the CsI photocathode is observed. The cha... The THGEM detector without and with a CsI has been tested successfully. The optimal parameters of THGEM have been determined from eight samples. The UV photoelectric effect of the CsI photocathode is observed. The changing tendency related to the extraction efficiency (εextr) versus the extraction electric field is measured, and several electric fields influencing the anode current are adjusted to adapt to the THGEM detector with a reflective CsI photocathode. 展开更多
关键词 THGEM CSI PHOTOCATHODE UV
原文传递
Thermal experiment of silicon PIN detector
7
作者 陈鸿飞 邹积清 +3 位作者 施伟红 邹鸿 胡然生 田大宇 《Chinese Physics C》 SCIE CAS CSCD 北大核心 2008年第10期820-824,共5页
The experiment of this paper is the thermal test of the leakage current of silicon PIN detector. Raising temperature may cause the detector to increase leakage current, decrease depletion and increase noise. Three sam... The experiment of this paper is the thermal test of the leakage current of silicon PIN detector. Raising temperature may cause the detector to increase leakage current, decrease depletion and increase noise. Three samples are used in the experiment. One (called △E) is the sample of 100 μm in thickness. The other two (called E1 and E2) are stacks of five detectors of 1000 μm in thickness. All of them are 12 mm in diameter. The experiment has been done for 21 hours and with power on continuously. The samples have undergone more than 60 ℃ for about one hour. They are not degenerated when back to the room temperature. The depletion rate is temperature and bias voltage related. With the circuit of the experiment and temperature at 35 ℃, △E is still depleted while E1 and E2 are 94.9% and 99.7% depleted respectively. The noises of the samples can be derived from the values at room temperature and the thermal dependence of the leakage currents. With the addition of the noise of the pre-amplifier, the noises of E1, E2 and △E at 24 ℃ are 16.4, 16.3, and 10.5 keV (FWHM) respectively while at 35 ℃ are about 33.6, 33.1, and 20.6 keV (FWHM) respectively. 展开更多
关键词 thermal effects PIN detector radiation detection energetic particle space environment
原文传递
Improved design and construction of an ionization chamber for the CSNS beam loss monitor (BLM)
8
作者 田建民 徐美杭 +5 位作者 赵中亮 陈昌 阮向东 陈元柏 徐韬光 陆双桐 《Chinese Physics C》 SCIE CAS CSCD 2012年第4期329-333,共5页
Based on the first ionization chamber (IC) prototype, the structure, working gas component and electrode material of the IC are improved. The test of the improved IC shows that the plateau length is about 2000 V, th... Based on the first ionization chamber (IC) prototype, the structure, working gas component and electrode material of the IC are improved. The test of the improved IC shows that the plateau length is about 2000 V, the plateau slope is less than 0.2%/100 V, the sensitivity is 19.6 pA/rad·h 1, the up-limitation of the linearity can be up to 3.6×105 rad/h, and the applied voltage can be operated to 3500 V. The test results show that the performance of the improved IC meets the requirements of the beam loss monitor. 展开更多
关键词 CSNS BLM detector ionization chamber plateau curve
原文传递