期刊文献+
共找到205篇文章
< 1 2 11 >
每页显示 20 50 100
A Study of the TPS Based Beam-Matching Concept for Medical Linear Accelerators at a Tertiary Hospital
1
作者 Ntombela N. Lethukuthula Rovetto J. Nicolas +1 位作者 Nethwadzi C. Lutendo Mpumelelo Nyathi 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2024年第1期16-25,共10页
The flexibility in radiotherapy can be improved if patients can be moved between any one of the department’s medical linear accelerators (LINACs) without the need to change anything in the patient’s treatment plan. ... The flexibility in radiotherapy can be improved if patients can be moved between any one of the department’s medical linear accelerators (LINACs) without the need to change anything in the patient’s treatment plan. For this to be possible, the dosimetric characteristics of the various accelerators must be the same, or nearly the same. The purpose of this work is to describe further and compare measurements and parameters after the initial vendor-recommended beam matching of the five LINACs. Deviations related to dose calculations and to beam matched accelerators may compromise treatment accuracy. The safest and most practical way to ensure that all accelerators are within clinical acceptable accuracy is to include TPS calculations in the LINACs matching evaluation. Treatment planning system (TPS) was used to create three photons plans with different field sizes 3 × 3 cm, 10 × 10 cm and 25 × 25 cm at a depth of 4.5 cm in Perspex. Calculated TPS plans were sent to Mosaiq to be delivered by five LINACs. TPS plans were compared with five LINACs measurements data using Gamma analyses of 2% and 2 mm. The results suggest that for four out of the five LINACs, there was generally good agreement, less than a 2% deviation between the planned dose distribution and the measured dose distribution. However, one specific LINAC named “Asterix” exhibited a deviation of 2.121% from the planned dose. The results show that all of the LINACs’ performance were within the acceptable deviation and delivering radiation dose consistently and accurately. 展开更多
关键词 RADIOTHERAPY Beam-Matching Linear Accelerator DOSIMETRY
下载PDF
Patient dose from radiographic rejects/repeats in radiology centers of Urmia University of Medical Sciences, Iran
2
作者 Nasrollah Jabbari Ahad Zeinali Leili Rahmatnezhad 《Health》 2012年第2期94-100,共7页
Medical diagnostic X-rays are the largest manmade source of ionizing radiation received by the members of the general public. The aim of this study was to evaluate the radiographic reject/repeat rate and also to deter... Medical diagnostic X-rays are the largest manmade source of ionizing radiation received by the members of the general public. The aim of this study was to evaluate the radiographic reject/repeat rate and also to determine dose to the patients from radiographic rejects/repeats in radiology centers of Urmia University of Medical Sciences. During a 4 month period the most frequently examinations were chosen in three radiology centers. A form was designed as a reject/repeat analysis form for radiographers to complete each time a film was rejected by radiologists or repeated. The collected data were compiled at the end of each week and entered into a computer for analysis at the end of study. The results of this study showed that highest and lowest repetition rates were for pelvis, 14.01% and upper limb, 4.17%, respectively. The main reasons of repetition of radiographs were due to exposure (54%) and positioning (18%) errors. The average repeat rate in all three hospitals was 7.20%. It was found that human error has important role to repetition of radiographs. It is demonstrated that those patients having repeated radiographs received an average of 3.23 Gy·cm2. Based on the findings of this study it must be remembered that the highest repetition rate was for pelvis. Considering the radiosensitive organs related to pelvis especially in pediatric patients some special considerations must be applied for pelvis examinations. 展开更多
关键词 Patient Dose RADIOGRAPHY Exposure REPEAT Rate
下载PDF
Long-term outcomes after endoscopic removal of malignant colorectal polyps:Results from a 10-year cohort 被引量:1
3
作者 Anna Fábián Renáta Bor +13 位作者 Béla Vasas Mónika Szűcs Tibor Tóth Zsófia Bősze Kata Judit Szántó Péter Bacsur Anita Bálint Bernadett Farkas Klaudia Farkas Ágnes Milassin Mariann Rutka Tamás Resál Tamás Molnár Zoltán Szepes 《World Journal of Gastrointestinal Endoscopy》 2024年第4期193-205,共13页
BACKGROUND Choosing an optimal post-polypectomy management strategy of malignant colorectal polyps is challenging,and evidence regarding a surveillance-only strategy is limited.AIM To evaluate long-term outcomes after... BACKGROUND Choosing an optimal post-polypectomy management strategy of malignant colorectal polyps is challenging,and evidence regarding a surveillance-only strategy is limited.AIM To evaluate long-term outcomes after endoscopic removal of malignant colorectal polyps.METHODS A single-center retrospective cohort study was conducted to evaluate outcomes after endoscopic removal of malignant colorectal polyps between 2010 and 2020.Residual disease rate and nodal metastases after secondary surgery and local and distant recurrence rate for those with at least 1 year of follow-up were invest-igated.Event rates for categorical variables and means for continuous variables with 95%confidence intervals were calculated,and Fisher’s exact test and Mann-Whitney test were performed.Potential risk factors of adverse outcomes were RESULTS In total,135 lesions(mean size:22.1 mm;location:42%rectal)from 129 patients(mean age:67.7 years;56%male)were enrolled.The proportion of pedunculated and non-pedunculated lesions was similar,with en bloc resection in 82%and 47%of lesions,respectively.Tumor differentiation,distance from resection margins,depth of submucosal invasion,lymphovascular invasion,and budding were reported at 89.6%,45.2%,58.5%,31.9%,and 25.2%,respectively.Residual tumor was found in 10 patients,and nodal metastasis was found in 4 of 41 patients who underwent secondary surgical resection.Univariate analysis identified piecemeal resection as a risk factor for residual malignancy(odds ratio:1.74;P=0.042).At least 1 year of follow-up was available for 117 lesions from 111 patients(mean follow-up period:5.59 years).Overall,54%,30%,30%,11%,and 16%of patients presented at the 1-year,3-year,5-year,7-year,and 9-10-year surveillance examinations.Adverse outcomes occurred in 9.0%(local recurrence and dissemination in 4 patients and 9 patients,respectively),with no difference between patients undergoing secondary surgery and surveillance only.CONCLUSION Reporting of histological features and adherence to surveillance colonoscopy needs improvement.Long-term adverse outcome rates might be higher than previously reported,irrespective of whether secondary surgery was performed. 展开更多
关键词 Malignant colorectal polyps T1 tumor Endoscopic removal OUTCOMES Long-term SURVEILLANCE
下载PDF
Simulating Medical Imaging X-Ray Tubes with Various Parameters Using BEAMnrc Monte Carlo Software
4
作者 Nikolaos Chatzisavvas Thanasis Koustas +3 位作者 Georgios Karpetas Ioannis Valais Georgios Priniotakis Dimitrios Nikolopoulos 《Open Journal of Radiology》 2022年第3期125-141,共17页
Context: Medical imaging has a wide range of applications in today’s society. Basic projectional radiography, CT scans, mammograms and a range of other advanced technologies all use x-rays to create a large number of... Context: Medical imaging has a wide range of applications in today’s society. Basic projectional radiography, CT scans, mammograms and a range of other advanced technologies all use x-rays to create a large number of examinations every day across the world. The most essential component of such medical equipment is the x-ray tube, which creates and produces x-rays. Objective: We describe and investigate an abstract model-geometry of a simple x-ray tube utilizing the open-source software package of BEAMnrc of the EGSnrcmp family, which is well validated by several studies over the years, for high and low energy photons generation. Methodology: Our research focuses on two different electron beam energies: 120 keV and 30 keV. The 120 keV is the typical energy for simple projectional radiographic exams and CT examinations, whereas the 30 keV is the typical energy of mammography. Results: Two different anode materials are used for each case, Gold (Au) and Tungsten (W) for 120 keV because these are the most common in projectional radiography and CT;Molybdenum (Mo) and Rhodium (Rh) for 30 keV because with these targets most mammography exams are carried out. The aim of this work is to show how the BEAMnrc software package can simulate effectively x-ray generation of low-energy photons which are utilized in modern medical imaging procedures. We describe useful information on anode-target characteristics, such as anode angle, anode material, and metal filter materials, based on previous quality studies even by using software other than BEAMnrc. Conclusion: We demonstrate that BEAMnrc can be efficiently used for Monte Carlo modeling of low-energy photons. 展开更多
关键词 BREMSSTRAHLUNG FILTER Monte Carlo Spectral Distribution X-Ray Tube
下载PDF
Inter-Fraction Analysis of One Week Hypo-Fractionation of Deep Inspiration Breath Hold (DIBH) Technique for Left Sided Breast Cancer Radiation Treatment
5
作者 Ntombela N. Lethukuthula Mathuthu Manny Nyathi Mpumelelo 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2024年第3期41-52,共12页
The aim of this study was to investigate the inter-fraction variations, patient comfort and knowledge at Charlotte Maxeke Johannesburg Academic Hospital (CMJAH). The differences in set-up that occurred between treatme... The aim of this study was to investigate the inter-fraction variations, patient comfort and knowledge at Charlotte Maxeke Johannesburg Academic Hospital (CMJAH). The differences in set-up that occurred between treatment sessions for the left sided breast patients were observed and recorded. Measurements of routine set-up variation for 24 patients were performed by matching the cone beam computed tomography (CBCT) and the planning computed tomography (CT). Scans of all five fractions per patient were used to quantify the setup variations with standard deviation (SD) in all the three directions (anterior posterior, left right, and superior inferior). The patients DIBH comfort and knowledge was also evaluated. The average translational errors for the anterior posterior (AP, z), left-right (LR, x), and Superior-inferior (SI, y) directions were 0.40 cm, 0.40 cm, and 0.40 cm, respectively. The translation variation of the three directions showed statistical significance (P < 0.05). On comfort and knowledge investigation, among all participants, 80% moderately agreed that the therapist’s instructions for operating the deep inspiration breath hold (DIBH) technique were easy to understand, and 63.33% indicated that their comfort with the DIBH technique was neutral or average. The inter-fraction variations in patients with left-sided breast cancer were qualitatively analyzed. Significant shifts between CBCT and planning CT images were observed. The daily treatment verification could assist accurate dose delivery. 展开更多
关键词 Breast Cancer Deep Inspiration Breath Hold Hypo-Fractionation Inter-Fraction
下载PDF
Evaluation of Particle Properties of MgO/TiO2 Material by Monte Carlo Simulation Method
6
作者 Koffi N’guessan Placide Gabin Allangba Yves Kily Hervé Fagnidi +2 位作者 Hermann N’guessan Zié Traoré Koffi Arnaud Kamenan 《Journal of Materials Science and Chemical Engineering》 2024年第2期49-60,共12页
The simulation by the Monte Carlo method executed by the software PyPENELOPE proved effective to specify the particle propagation characteristics by calculating the absorption fractions, backscattering and transmissio... The simulation by the Monte Carlo method executed by the software PyPENELOPE proved effective to specify the particle propagation characteristics by calculating the absorption fractions, backscattering and transmission of electrons and secondary photons under the incidence of 0.5 to 20 KeV range of primary electrons. More than 99.9% of the primary electrons were transmitted in the 125 nm thick MgO/TiO<sub>2</sub> material at 20 KeV. This occurred because several interactions took place in the transmitted primary irradiation such as characteristic, fluorescence, and bremsstrahlung produced when of the occupation of the KL3, KL2, KM3, and KM2 shell and sub-shell of titanium and magnesium which are the elements with a high atomic number in the material. The transmission particle characteristic of this material is therefore an indicator capable of improving the electrical performance and properties of the sensor. 展开更多
关键词 Monte Carlo PyPENELOPE Primary Electrons Transmission MgO/TiO2
下载PDF
Apparent diffusion coefficient values of normal testis and variations with age 被引量:8
7
作者 Athina C Tsili Dimitrios Giannakis +4 位作者 Anastasios Sylakos Alexandra Ntorkou Loukas G Astrakas Nikolaos Sofikitis Maria I Argyropoulou 《Asian Journal of Andrology》 SCIE CAS CSCD 2014年第3期493-497,共5页
The usefulness of diffusion-weighted magnetic resonance imaging (DWI) in the evaluation of scrotal pathology has recently been reported. A standard reference of normal testicular apparent diffusion coefficient (ADC... The usefulness of diffusion-weighted magnetic resonance imaging (DWI) in the evaluation of scrotal pathology has recently been reported. A standard reference of normal testicular apparent diffusion coefficient (ADC) values and their variations with age is necessary when interpreting normal testicular anatomy and pathology. We evaluated 147 normal testes using DWI, including 71 testes from 53 men aged 20-39years (group 1), 67 testes from 42 men aged 40-69 years (group 2) and nine testes from six men older than 70years (group 3). DWI was performed along the axial plane, using a single shot, multislice spin-echo planar diffusion pulse sequence and b-values of 0 and 900 s mm-2. The mean and standard deviation of the ADC values of normal testicular parenchyma were calculated for each age group separately. Analysis of variance (ANOVA) followed by post hoc analysis (Dunnett T3) was used for statistical purposes. The ADC values (x 10-3 mm2s-1) of normal testicular tissue were different among age groups (group 1:1.08 ± 0.13; group 2:1.15 ±0.15 and group 3:1.31± 0.22). ANOVA revealed differences in mean ADC among age groups (F= 11.391, P〈 0.001). Post hoc analysis showed differences between groups 1 and 2 (P= 0.008) and between groups 1 and 3 (P= 0.043), but not between groups 2 and 3 (P= 0.197). Our findings suggest that ADC values of normal testicular tissue increase with advancing age. 展开更多
关键词 age apparent diffusion coefficient (ADC) DIFFUSION-WEIGHTED magnetic resonance imaging TESTIS
下载PDF
Dynamic contrast-enhanced magnetic resonance imaging of prostate cancer: A review of current methods and applications 被引量:8
8
作者 Yousef Mazaheri Oguz Akin Hedvig Hricak 《World Journal of Radiology》 CAS 2017年第12期416-425,共10页
In many areas of oncology, dynamic contrast-enhanced magnetic resonance imaging(DCE-MRI) has proven to be a clinically useful, non-invasive functional imaging technique to quantify tumor vasculature and tumor perfusio... In many areas of oncology, dynamic contrast-enhanced magnetic resonance imaging(DCE-MRI) has proven to be a clinically useful, non-invasive functional imaging technique to quantify tumor vasculature and tumor perfusion characteristics. Tumor angiogenesis is an essential process for tumor growth, proliferation, and metastasis. Malignant lesions demonstrate rapid extravasation of contrast from the intravascular space to the capillary bed due to leaky capillaries associated with tumor neovascularity. DCE-MRI has the potential to provide information regarding blood flow, areas of hypoperfusion, and variations in endothelial permeability and microvessel density to aid treatment selection, enable frequent monitoring during treatment and assess response to targeted therapy following treatment. This review will discuss the current status of DCE-MRI in cancer imaging, with a focus on its use in imaging prostate malignancies as well as weaknesses that limit its widespread clinical use. The latest techniques for quantification of DCE-MRI parameters will be reviewed and compared. 展开更多
关键词 Prostate cancer Prostate magnetic resonance imaging Tumor angiogenesis Dynamic contrast-enhanced magnetic resonance imaging Kep = rate constant between extracellular extravascular space and plasma space Ktrans = volume transfer constant
下载PDF
Combined value of apparent diffusion coefficient-standardized uptake value max in evaluation of post-treated locally advanced rectal cancer 被引量:5
9
作者 Davide Ippolito Davide Fior +5 位作者 Chiara Trattenero Elena De Ponti Silvia Drago Luca Guerra Cammillo Talei Franzesi Sandro Sironi 《World Journal of Radiology》 CAS 2015年第12期509-520,共12页
AIM:To assess the clinical diagnostic value of functional imaging,combining quantitative parameters of apparent diffusion coefficient(ADC) and standardized uptake value(SUV)max,before and after chemo-radiation therapy... AIM:To assess the clinical diagnostic value of functional imaging,combining quantitative parameters of apparent diffusion coefficient(ADC) and standardized uptake value(SUV)max,before and after chemo-radiation therapy,in prediction of tumor response of patients with rectal cancer,related to tumor regression grade at histology.METHODS:A total of 31 patients with biopsy proven diagnosis of rectal carcinoma were enrolled in our study.All patients underwent a whole body ^(18)FDG positron emission tomography(PET)/computed tomography(CT) scan and a pelvic magnetic resonance(MR)examination including diffusion weighted(DW) imaging for staging(PET1,RM1) and after completion(6.6 wk)of neoadjuvant treatment(PET2,RM2).Subsequently all patients underwent total mesorectal excision and the histological results were compared with imaging findings.The MR scanning,performed on 1.5 T magnet(Philips,Achieva),included T2-weighted multiplanar imaging and in addition DW images with b-value of 0 and 1000 mm^2/s.On PET/CT the SUVmax of the rectal lesion were calculated in PET1 and PET2.The percentage decrease of SUVmax(△SUV) and ADC(△ADC) values from baseline to presurgical scan were assessed and correlated with pathologic response classified as tumor regression grade(Mandard's criteria;TRG1 = complete regression,TRG5 = no regression).RESULTS:After completion of therapy,all the patients were submitted to surgery.According to the Mandard's criteria,22 tumors showed complete(TRG1) or subtotal regression(TRG2) and were classified as responders;9tumors were classified as non responders(TRG3,4 and5).Considering all patients the mean values of SUVmax in PET 1 was higher than the mean value of SUVmax in PET 2(P < 0.001),whereas the mean ADC values was lower in RM1 than RM2(P < 0.001),with a △SUV and △ADC respectively of 60.2%and 66.8%.The best predictors for TRG response were SUV2(threshold of4.4) and ADC2(1.29 × 10^(-3) mm^2/s) with high sensitivity and specificity.Combining in a single analysis both the obtained median value,the positive predictive value,in predicting the different group category response in related to TRG system,presented R^2 of 0.95.CONCLUSION:The functional imaging combining ADC and SUVmax in a single analysis permits to detect changes in cellular tissue structures useful for the assessment of tumour response after the neoadjuvant therapy in rectal cancer,increasing the sensitivity in correct depiction of treatment response than either method alone. 展开更多
关键词 Advanced RECTAL cancer Functional IMAGING FDG-PET/CT Magnetic resonance IMAGING APPARENT diffusion coefficient NEOADJUVANT treatment Tumor regression grade
下载PDF
Virtual endoscopy of the urinary tract 被引量:4
10
作者 George C.Kagadis Dimitrios Siablis +2 位作者 Evangelos N.Liatsikos Theodore Petsas George C. Nikiforidis 《Asian Journal of Andrology》 SCIE CAS CSCD 2006年第1期31-38,共8页
Technological breakthroughs have advanced the temporal and spatial resolutions of diagnostic imaging, and 3 dimensional (3-D) reconstruction techniques have been introduced into everyday clinical practice. Virtual e... Technological breakthroughs have advanced the temporal and spatial resolutions of diagnostic imaging, and 3 dimensional (3-D) reconstruction techniques have been introduced into everyday clinical practice. Virtual endoscopy (VE) is a non-invasive technique that amplifies the perception of cross-sectional images in the 3-D space, providing precise spatial relationships of pathological regions and their surrounding structures. A variety of computer algorithms can be used to generate 3-D images, taking advantage of the information inherent in either spiral computed tomography or magnetic resonance imaging (MRI). VE images enable endoluminal navigation through hollow organs, thus simulating conventional endoscopy. Several clinical studies have validated the diagnostic utility of virtual cystoscopy, which has high sensitivity and specificity rates in the detection of bladder tumor. Published experience in the virtual exploration of the renal pelvis, ureter and urethra is encouraging but still scarce. VE is a safe, non-invasive method that could be applied in the long-term follow-up of patients with ureteropelvic junction obstruction, urinary bladder tumors and ureteral and/or urethral strictures. Its principal limitations are the inability to provide biopsy tissue specimens for histopathologic examination and the associated ionizing radiation hazards (unless MR/is used). However, in the case of endoluminal stenosis or obstruction, VE permits virtual endoluminal navigation both cephalad and caudal to the stenotic segment. To conclude, VE provides a less invasive method of evaluating the urinary tract, especially for clinicians who are less familiar with cross-sectional imaging than radiologists. (Asian J Androl 2006 Jan; 8: 31-38) 展开更多
关键词 computed tomography three-dimensional imaging virtual endoscopy urethral stricture
下载PDF
Optical and magnetic properties of porous anodic alumina films embedded with Co nanowires 被引量:4
11
作者 张敬晶 李子岳 +2 位作者 张惠敏 侯雪 孙会元 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第8期671-674,共4页
A simple method to tune the optical properties of porous anodic alumina (PAA) films embedded with Co nanowires (PAA@Co nanocomposite films) is reported in this paper. The films exhibit vivid structural colors and ... A simple method to tune the optical properties of porous anodic alumina (PAA) films embedded with Co nanowires (PAA@Co nanocomposite films) is reported in this paper. The films exhibit vivid structural colors and magnetic properties. The optical properties of the films can be effectively tuned by adjusting the thickness of the PAA template. The deposition of Co nanowires greatly increases the color saturation of the PAA films. The theoretical results of the changes in structural color according to the Bragg-Snell formula are consistent with the experimental results. PAA@Co films can be used in many areas, including decoration, display, and multifunctional anti-counterfeiting applications. 展开更多
关键词 NANOCOMPOSITES thin films optical and magnetic properties porous materials
下载PDF
Transcranial direct current stimulation for auditory verbal hallucinations:a systematic review of clinical trials 被引量:5
12
作者 Samaneh Rashidi Myles Jones +3 位作者 Eric Murillo-Rodriguez Sergio Machado Youguo Hao Ali Yadollahpour 《Neural Regeneration Research》 SCIE CAS CSCD 2021年第4期666-671,共6页
Transcranial direct current stimulation(tDCS)has been reportedly beneficial for different neurodegenerative disorders.tDCS has been reported as a potential adjunctive or alternative treatment for auditory verbal hallu... Transcranial direct current stimulation(tDCS)has been reportedly beneficial for different neurodegenerative disorders.tDCS has been reported as a potential adjunctive or alternative treatment for auditory verbal hallucination(AVH).This study aims to review the effects of tDCS on AVH in patients with schizophrenia through combining the evidence from randomized clinical trials(RCTs).The databases of PsycINFO(2000–2019),PubMed(2000–2019),EMBASE(2000–2019),CINAHL(2000–2019),Web of Science(2000–2019),and Scopus(2000–2019)were systematically searched.The clinical trials with RCT design were selected for final analysis.A total of nine RCTs were eligible and included in the review.Nine RCTs were included in the final analysis.Among them,six RCTs reported a significant reduction of AVH after repeated sessions of tDCS,whereas three RCTs did not show any advantage of active tDCS over sham tDCS.The current studies showed an overall decrease of approximately 28%of AVH after active tDCS and 10%after sham tDCS.The tDCS protocols targeting the sensorimotor frontal-parietal network showed greater treatment effects compared with the protocols targeting other regions.In this regard,cathodal tDCS over the left temporoparietal area showed inhibitory effects on AVHs.The most effective tDCS protocol on AVHs was twice-daily sessions(2 mA,20-minute duration)over 5 consecutive days(10 sessions)with the anode over the left dorsolateral prefrontal cortex and the cathode over the left temporal area.Some patient-specific and diseasespecific factors such as young age,nonsmoking status,and higher frequencies of AVHs seemed to be the predictors of treatment response.Taken together,the results of tDCS as an alternative treatment option for AVH show controversy among current literatures,since not all studies were positive.However,the studies targeting the same site of the brain showed that the tDCS could be a promising treatment option to reduce AVH.Further RCTs,with larger sample sizes,should be conducted to reach a conclusion on the efficacy of tDCS for AVH and to develop an effective therapeutic protocol for clinical setting. 展开更多
关键词 auditory verbal hallucinations dorsolateral prefrontal cortex effective protocol randomized clinical trial schizophrenia temporoparietal area transcranial direct current stimulation treatment efficacy
下载PDF
Visual Analysis of the Daily QA Results of Photon and Electron Beams of a Trilogy Linac over a Five-Year Period 被引量:6
13
作者 Maria F. Chan Qiongge Li +5 位作者 Xiaoli Tang Xiang Li Jingdong Li Grace Tang Margie A. Hunt Joseph O. Deasy 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2015年第4期290-299,共10页
Data visualization technique was applied to analyze the daily QA results of photon and electron beams. Special attention was paid to any trend the beams might display. A Varian Trilogy Linac equipped with dual photon ... Data visualization technique was applied to analyze the daily QA results of photon and electron beams. Special attention was paid to any trend the beams might display. A Varian Trilogy Linac equipped with dual photon energies and five electron energies was commissioned in early 2010. Daily Linac QA tests including the output constancy, beam flatness and symmetry (radial and transverse directions) were performed with an ionization chamber array device (QA Beam Checker Plus, Standard Imaging). The data of five years were collected and analyzed. For each energy, the measured data were exported and processed for visual trending using an in-house Matlab program. These daily data were cross-correlated with the monthly QA and annual QA results, as well as the preventive maintenance records. Majority of the output were within 1% of variation, with a consistent positive/upward drift for all seven energies (^+0.25% per month). The baseline of daily device is reset annually right after the TG-51 calibration. This results in a sudden drop of the output. On the other hand, the large amount of data using the same baseline exhibits a sinusoidal behavior (period = 12 months;amplitude = 0.8%, 0.5% for photons, electrons, respectively) on symmetry and flatness when normalization of baselines is accounted for. The well known phenomenon of new Linac output drift was clearly displayed. This output drift was a result of the air leakage of the over-pressurized sealed monitor chambers for the specific vendor. Data visualization is a new trend in the era of big data in radiation oncology research. It allows the data to be displayed visually and therefore more intuitive. Based on the visual display from the past, the physicist might predict the trend of the Linac and take actions proactively. It also makes comparisons, alerts failures, and potentially identifies causalities. 展开更多
关键词 LINAC QA Data Visualization DAILY Output RADIOTHERAPY
下载PDF
Verification and Dosimetric Impact of Acuros XB Algorithm for Stereotactic Body Radiation Therapy (SBRT) and RapidArc Planning for Non-Small-Cell Lung Cancer (NSCLC) Patients 被引量:3
14
作者 Suresh Rana Kevin Rogers +2 位作者 Terry Lee Daniel Reed Christopher Biggs 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2013年第1期6-14,共9页
Purpose: The experimental verification of the Acuros XB (AXB) algorithm was conducted in a heterogeneous rectangular slab phantom, and compared to the Anisotropic Analytical Algorithm (AAA). The dosimetric impact of t... Purpose: The experimental verification of the Acuros XB (AXB) algorithm was conducted in a heterogeneous rectangular slab phantom, and compared to the Anisotropic Analytical Algorithm (AAA). The dosimetric impact of the AXB for stereotactic body radiation therapy (SBRT) and RapidArc planning for 16 non-small-cell lung cancer (NSCLC) patients was assessed due to the dose recalculation from the AAA to the AXB. Methods: The calculated central axis percentage depth doses (PDD) in a heterogeneous slab phantom for an open field size of 3 ×3 cm2 were compared against the PDD measured by an ionization chamber. For 16 NSCLC patients, the dose-volume parameters from the treatment plans calculated by the AXB and the AAA were compared using identical jaw settings, leaf positions, and monitor units (MUs). Results: The results from the heterogeneous slab phantom study showed that the AXB was more accurate than the AAA;however, the dose underestimation by the AXB (up to ?3.9%) and AAA (up to ?13.5%) was observed. For a planning target volume (PTV) in the NSCLC patients, in comparison to the AAA, the AXB predicted lower mean and minimum doses by average 0.3% and 4.3% respectively, but a higher maximum dose by average 2.3%. The averaged maximum doses to the heart and spinal cord predicted by the AXB were lower by 1.3% and 2.6% respectively;whereas the doses to the lungs predicted by the AXB were higher by up to 0.5% compared to the AAA. The percentage of ipsilateral lung volume receiving at least 20 and 5 Gy (V20 and V5 respectively) were higher in the AXB plans than in the AAA plans by average 1.1% and 2.8% respectively. The AXB plans produced higher target heterogeneity by average 4.5% and lower plan conformity by average 5.8% compared to the AAA plans. Using the AXB, the PTV coverage (95% of the PTV covered by the 100% of the prescribed dose) was reduced by average 8.2% than using the AAA. The AXB plans required about 2.3% increment in the number of MUs in order to achieve the same PTV coverage as in the AAA plans. Conclusion: The AXB is more accurate to use for the dose calculations in SBRT lung plans created with a RapidArc technique;however, one should also note the reduced PTV coverage due to the dose recalculation from the AAA to the AXB. 展开更多
关键词 Acuros XB AAA HETEROGENEITY Correction SBRT RAPIDARC LUNG Cancer
下载PDF
Chemical Analysis of Hydroxyapatite Artificial Bone Powders by Energy Dispersive X-Ray Fluorescence Spectrometry(EDXRF) 被引量:2
15
作者 O.K.Koksal G.Apaydin +4 位作者 E.Cengiz L.Samek I.H.Karahan A.Tozar M.Lankosz 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2018年第8期2645-2649,共5页
Stoichiometric hydroxyapatite(HA)nanoparticles were synthesized by a wet chemical method.Calcium nitrate tetra hydrate used as calcium source and dibasic ammonium phosphate used as phosphorous source.Calcium nitrate t... Stoichiometric hydroxyapatite(HA)nanoparticles were synthesized by a wet chemical method.Calcium nitrate tetra hydrate used as calcium source and dibasic ammonium phosphate used as phosphorous source.Calcium nitrate tetra hydrate and dibasic ammonium phosphate solutions were prepared by dissolving the salts in distilled water.Stoichiometric hydroxyapatite nanoparticles used by artificial bone powders and synthesized by a wet chemical method were analyzed using EDXRF method.The concentrations of K,Ca,Ti,V,Cr,Fe,Ni,Cu,Sr and Pb for artificial bone powders have been determined.Besides,Calcium contents were evaluated according to the agitation time and temperature in the production process. 展开更多
关键词 EDXRF X-ray Tube Elemental analysis HYDROXYAPATITE
下载PDF
Effects of Beam Startup Characteristics on Dose Delivery Accuracy at Low Monitor Units in Step-and-Shoot Intensity Modulated Radiation Therapy 被引量:3
16
作者 Kazunori Fujimoto Kunihiko Tateoka +12 位作者 Yuji Yaegashi Katsumi Shima Junji Suzuki Yuichi Saito Akihiro Nakata Takuya Nakazawa Tadanori Abe Masaki Yano Masanori Someya Kensei Nakata Masakazu Hori Masato Hareyama Koichi Sakata 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2013年第1期1-5,共5页
Intensity modulated radiation therapy (IMRT) is a highly accurate technique that is usually implemented in either dynamic or step-and-shoot fashion with many segments each having low monitor units (MUs). The present s... Intensity modulated radiation therapy (IMRT) is a highly accurate technique that is usually implemented in either dynamic or step-and-shoot fashion with many segments each having low monitor units (MUs). The present study evaluated the effects of beam startup characteristics on the dose delivery accuracy for each segment at low MUs for step-and-shoot IMRT with an Elekta Precise accelerator at the highest dose rates. We used a two-dimensional semi-conductor detector for the dose measurements. The field size of each segment was assumed to be 20 ×20 cm2 and each segment was set to deliver 1 - 10 MUs. Our results show a variation in dose delivery accuracy between segments for the same IMRT beam, which can be attributed to the beam startup characteristics. This variability is attributed to the changes in the transient changes in the temperatures of the electron gun filament and the magnetron. That is, the transient increase in the temperature of the filament leads to increasing doses with time and that of the magnetron leads to decreasing doses with time during the first few MUs. 展开更多
关键词 Startup Performance Step-and-Shoot IMRT LOW MONITOR UNITS
下载PDF
Photodynamic therapy of oral leukoplakia and orallichen planus using methylene blue:A pilot study 被引量:2
17
作者 Savarimuthu Wilfred Prasanna Ekta Ingle +3 位作者 Prakasa Rao Aruna Chidambaranathan Pravada Dornadula Koteeswaran S.Ganesan 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2015年第1期95-105,共11页
Premalignant lesions like oral lichen planus(OLP),oral leukoplakia(OL)has a fair probability of transforming into malignancy and they are perverse toward conventional therapies.Photody-namic therapy(PDT)has been consi... Premalignant lesions like oral lichen planus(OLP),oral leukoplakia(OL)has a fair probability of transforming into malignancy and they are perverse toward conventional therapies.Photody-namic therapy(PDT)has been considered as an alternative/complimentary therapeutic mo-dality for the management of premalignant lesions.In this study,methylene blue mediated photodynamic therapy(MB-PDT)was used as a possible alternative method for the treatment of OLP and OL.A total of 15 OLP lesions and 13 OL lesions were enrolled in the study.The patients were irradiated 1using metal halide lamp filtered at 630土10nm,with a light exposure dose of 120 J/cm^(2) per stting.For the OLP lesions,MB-PDT was performed once a week for four weeks and for the OL lesions,MB-PDT was performed twice a week for three weeks.Lesions were evaluated pre-and post-and at follow-u sessions by changes in sign and symptom scores,and size of lesions.We have observed a 53.3%of complete reduction in the treated OLP lesions and their decrease in size,sign and symptom score after treatment and at follow-up session was statistially signifcant.We have also observed complete response for one OL lesion of the 13 treated lesions.The result indicates that MB-PDT is an effective modality in management of OLP and OL.Among the two types of premalignancies treated with MB-PDT,OLP lesions responded much better than that of OL. 展开更多
关键词 Photodynamic therapy methylene blue oral lichen planus oral leukoplakia
下载PDF
Assessment of biological changes in wheat seedlings induced by ^(12)C^(6+)-ion irradiation 被引量:2
18
作者 ZHANG Luwei ZHANG Hong +1 位作者 ZHANG Xiaofu ZHU Jianlan 《Nuclear Science and Techniques》 SCIE CAS CSCD 2008年第3期138-141,共4页
The present study was designed to evaluate the effect of 12 6+ C ion beam (10~80 Gy) on biological changes of wheat seedlings. Reactive oxygen species (ROS)-related biomarkers and the quantification of plant survival... The present study was designed to evaluate the effect of 12 6+ C ion beam (10~80 Gy) on biological changes of wheat seedlings. Reactive oxygen species (ROS)-related biomarkers and the quantification of plant survival and growth were examined at 10 day after carbon ions irradiation (LET: 30.8 keV/μm). The results showed that heavy ions obviously enhanced ROSs reflected by the production of O2 and H2O2 as well as TBARS, and - treatment with 20 Gy achieved the peak value, suggesting that higher mutagenic potential may occur at 20 Gy. Simultaneously, increase of SOD activity was induced by heavy ions to counteract ROS accumulation. On the other hand, higher doses at 40 and 80 Gy inhibited wheat growth and survival in comparison with the control, and reversely lower doses at 10 or 20 Gy stimulated wheat growth and survival. In conclusion, the above observations imply that a dose range of 20~40 Gy is likely promised for wheat mutation breeding. 展开更多
关键词 离子 电离辐射 植物生长 辐射损伤
下载PDF
Multimodality functional imaging using DW-MRI and 18F-FDG-PET/CT during radiation therapy for human papillomavirus negative head and neck squamous cell carcinoma: Meixoeiro Hospital of Vigo Experience 被引量:2
19
作者 David Aramburu Núnez Antonio Lopez Medina +8 位作者 Moisés Mera Iglesias Francisco Salvador Gomez Abhay Dave Vaios Hatzoglou Ramesh Paudyal Alfonso Calzado Joseph O Deasy Amita Shukla-Dave Victor M Munoz 《World Journal of Radiology》 CAS 2017年第1期17-26,共10页
AIMTo noninvasively investigate tumor cellularity measured using diffusion-weighted magnetic resonance imaging (DW-MRI) and glucose metabolism measured by <sup>18</sup>F-labeled fluorodeoxyglucose positron... AIMTo noninvasively investigate tumor cellularity measured using diffusion-weighted magnetic resonance imaging (DW-MRI) and glucose metabolism measured by <sup>18</sup>F-labeled fluorodeoxyglucose positron emission tomography/computed tomography (<sup>18</sup>F-FDG-PET/CT) during radiation therapy (RT) for human papillomavirus negative (HPV-) head and neck squamous cell carcinoma (HNSCC).METHODSIn this prospective study, 6 HPV- HNSCC patients underwent a total of 34 multimodality imaging examinations DW-MRI at 1.5 T Philips MRI scanner [(n = 24) pre-, during- (2-3 wk), and post-treatment (Tx), and <sup>18</sup>F-FDG PET/CT pre- and post-Tx (n = 10)]. All patients received RT. Monoexponential modeling of the DW-MRI data yielded the imaging metric apparent diffusion coefficient (ADC) and the mean of standardized uptake value (SUV) was measured from <sup>18</sup>F-FDG PET uptake. All patients had a clinical follow-up as the standard of care and survival status was documented at 1 year.RESULTSThere was a strong negative correlation between the mean of pretreatment ADC (ρ = -0.67, P = 0.01) and the pretreatment <sup>18</sup>F-FDG PET SUV. The percentage (%) change in delta (∆) ADC for primary tumors and neck nodal metastases between pre- and Wk<sub>2-3</sub> Tx were as follows: 75.4% and 61.6%, respectively, for the patient with no evidence of disease, 27.5% and 32.7%, respectively, for those patients who were alive with disease, and 26.9% and 7.31%, respectively, for those who were dead with disease.CONCLUSIONThese results are preliminary in nature and are indicative, and not definitive, trends rendered by the imaging metrics due to the small sample size of HPV- HNSCC patients in a Meixoeiro Hospital of Vigo Experience. 展开更多
关键词 Diffusion-weighted magnetic resonance imaging Human papillomavirus negative head and neck squamous cell carcinoma 18F-labeled fluorodeoxyglucose positron emission tomography/computed tomography
下载PDF
Feasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment 被引量:1
20
作者 Suresh Rana ChihYao Cheng 《Chinese Journal of Cancer》 SCIE CAS CSCD 2013年第10期546-552,共7页
The volumetric modulated arc therapy(VMAT)technique,in the form of RapidArc,is widely used to treat prostate cancer.The full-single arc(f-SA)technique in RapidArc planning for prostate cancer treatment provides effici... The volumetric modulated arc therapy(VMAT)technique,in the form of RapidArc,is widely used to treat prostate cancer.The full-single arc(f-SA)technique in RapidArc planning for prostate cancer treatment provides efficient treatment,but it also delivers a higher radiation dose to the rectum.This study aimed to compare the dosimetric results from the new partial-single arc(p-SA)technique with those from the f-SA technique in RapidArc planning for prostate cancer treatment.In this study,10 patients with lowrisk prostate cancer were selected.For each patient,two sets of RapidArc plans(f-SA and p-SA)were created in the Eclipse treatment planning system.The f-SA plan was created using one full arc,and the p-SA plan was created using planning parameters identical to those of the f-SA plan but with anterior and posterior avoidance sectors.Various dosimetric parameters of the f-SA and p-SA plans were evaluated and compared for the same target coverage and identical plan optimization parameters.The f-SA and p-SA plans showed an average difference of±1%for the doses to the planning target volume(PTV),and there were no clear differences in dose homogeneity or plan conformity.In comparison to the f-SA technique,the p-SA technique reduced the doses to the rectum by approximately 6.1%to 21.2%,to the bladder by approximately 10.3%to 29.5%,and to the penile bulb by approximately 2.2%.In contrast,the dose to the femoral heads,the integral dose,and the number of monitor units were higher in the p-SA plans by approximately 34.4%,7.7%,and 9.2%,respectively.In conclusion,it is feasible to use the p-SA technique for RapidArc planning for prostate cancer treatment.For the same PTV coverage and identical plan optimization parameters,the p-SA technique is better in sparing the rectum and bladder without compromising plan conformity or target homogeneity when compared to the f-SA technique. 展开更多
关键词 治疗计划系统 SA技术 前列腺癌 ECLIPSE 辐射剂量 参数规划 优化参数 剂量分布
下载PDF
上一页 1 2 11 下一页 到第
使用帮助 返回顶部