Diesel particulate matter (DPM) is considered to be carcinogenic after prolonged exposure. With more diesel- powered equipment used in underground mines, miners' exposure to DPM has become an increasing concern. Th...Diesel particulate matter (DPM) is considered to be carcinogenic after prolonged exposure. With more diesel- powered equipment used in underground mines, miners' exposure to DPM has become an increasing concern. This paper used computational fluid dynamics method to study the DPM dispersion in a dead-end entry with loading operation. The effects of different push-pull ventilation systems on DPM distribution were evaluated to improve the working conditions for underground miners. The four push-pull systems considered include: long push and short pull tubing; short push and long pull tubing, long push and curved pull tubing, and short push and curved pull tubing. A species transport model with buoyancy effect was used to examine the DPM dispersion pattern with unsteady state analysis. During the 200 s of loading operation, high DPM levels were identified in the face and dead-end entry regions. This study can be used for mining engineer as guidance to design and setup local ventilation, select DPM control strategies and for DPM annual training for underground miners.展开更多
This paper aims at presenting different pumped-storage solutions for improving the energy efficiency and economic sustainability of water systems. The assessment of pumped-storage solutions, either using fresh water o...This paper aims at presenting different pumped-storage solutions for improving the energy efficiency and economic sustainability of water systems. The assessment of pumped-storage solutions, either using fresh water or sea-water, is seen as a viable option to solve problems of energy production, as well as in the integration of intermittent renewable energies, providing system flexibility due to energy loads’ fluctuation, as long as the storage of energy from intermittent sources. Pumped-storage is one of the best and most efficient options in terms of renewable resources as an integrated solution allowing the improvement of the energy system elasticity and the global system efficiency. Two real case studies are presented: a fresh water system installed in a river dams—the Alqueva system, in Portugal—and a sea-water system in an arid region of the Cape Verde Islands in Africa. These cases demonstrate the benefits associated to pumped-storage solutions, depending on the storage volume capacity, operational rules and energy tariffs.展开更多
This paper aims to deal with the assessment of axial load capacity for cast in place pile foundations, which are made by the earth drill method, by using the data taken from Standard Penetration Tests (SPTs) and Piezo...This paper aims to deal with the assessment of axial load capacity for cast in place pile foundations, which are made by the earth drill method, by using the data taken from Standard Penetration Tests (SPTs) and Piezocone Penetration Tests (CPTUs). These tests were carried out as part of the investigation program for P.N.G. Terminal-Power Plant, near Semani beach, in Hoxhara marsh, in the western part of Albania. The design of axial load capacity of piles is based on empirical formula using SPT and CPTU values. This study presents the results of axial load capacity analysis of cast in place piles by different analytical calculation methods, which are based on in situ tests results, and also referring to the Building Standard Law of Japan. In the end of our work, differences between calculations methods by using different in situ tests results are shown in tables and graphs.展开更多
The aim of the study is to assess the occurrence of fluoride in the groundwater of Kaltungo area and environs. Consumption of high fluoride waters clearly manifests in the majority inhabitant of the area in form of de...The aim of the study is to assess the occurrence of fluoride in the groundwater of Kaltungo area and environs. Consumption of high fluoride waters clearly manifests in the majority inhabitant of the area in form of dental fluorosis especially in the majority of the populace. Thirty groundwater samples were collected from hand-dug wells and boreholes using standard method and were analyzed to determine the fluoride level. The results revealed that the Fluoride in the waters ranges from 0.8 to 1.94 mg/l with a mean value of 1.65 mg/l. No clear variations in fluoride content have been observed in both the borehole samples and those from the hand-dug wells. Ca-Mg-HCO3 and Ca-Mg-Cl are the two major water types obtained in the area, which have a good association with fluoride. Negative correlation is observed between fluoride and temperature, fluoride and magnesium, fluoride and potassium and poor correlation is observed between fluoride and chloride, fluoride and nitrate, fluoride and phosphates which rules out the possibility of anthropogenic source of the fluoride in the waters. Positive correlation between fluoride and iron, indicates that the presence of fluoride in the water is as a result of dissolution of biotite within the host rock (Basalt).展开更多
文摘Diesel particulate matter (DPM) is considered to be carcinogenic after prolonged exposure. With more diesel- powered equipment used in underground mines, miners' exposure to DPM has become an increasing concern. This paper used computational fluid dynamics method to study the DPM dispersion in a dead-end entry with loading operation. The effects of different push-pull ventilation systems on DPM distribution were evaluated to improve the working conditions for underground miners. The four push-pull systems considered include: long push and short pull tubing; short push and long pull tubing, long push and curved pull tubing, and short push and curved pull tubing. A species transport model with buoyancy effect was used to examine the DPM dispersion pattern with unsteady state analysis. During the 200 s of loading operation, high DPM levels were identified in the face and dead-end entry regions. This study can be used for mining engineer as guidance to design and setup local ventilation, select DPM control strategies and for DPM annual training for underground miners.
文摘This paper aims at presenting different pumped-storage solutions for improving the energy efficiency and economic sustainability of water systems. The assessment of pumped-storage solutions, either using fresh water or sea-water, is seen as a viable option to solve problems of energy production, as well as in the integration of intermittent renewable energies, providing system flexibility due to energy loads’ fluctuation, as long as the storage of energy from intermittent sources. Pumped-storage is one of the best and most efficient options in terms of renewable resources as an integrated solution allowing the improvement of the energy system elasticity and the global system efficiency. Two real case studies are presented: a fresh water system installed in a river dams—the Alqueva system, in Portugal—and a sea-water system in an arid region of the Cape Verde Islands in Africa. These cases demonstrate the benefits associated to pumped-storage solutions, depending on the storage volume capacity, operational rules and energy tariffs.
文摘This paper aims to deal with the assessment of axial load capacity for cast in place pile foundations, which are made by the earth drill method, by using the data taken from Standard Penetration Tests (SPTs) and Piezocone Penetration Tests (CPTUs). These tests were carried out as part of the investigation program for P.N.G. Terminal-Power Plant, near Semani beach, in Hoxhara marsh, in the western part of Albania. The design of axial load capacity of piles is based on empirical formula using SPT and CPTU values. This study presents the results of axial load capacity analysis of cast in place piles by different analytical calculation methods, which are based on in situ tests results, and also referring to the Building Standard Law of Japan. In the end of our work, differences between calculations methods by using different in situ tests results are shown in tables and graphs.
文摘The aim of the study is to assess the occurrence of fluoride in the groundwater of Kaltungo area and environs. Consumption of high fluoride waters clearly manifests in the majority inhabitant of the area in form of dental fluorosis especially in the majority of the populace. Thirty groundwater samples were collected from hand-dug wells and boreholes using standard method and were analyzed to determine the fluoride level. The results revealed that the Fluoride in the waters ranges from 0.8 to 1.94 mg/l with a mean value of 1.65 mg/l. No clear variations in fluoride content have been observed in both the borehole samples and those from the hand-dug wells. Ca-Mg-HCO3 and Ca-Mg-Cl are the two major water types obtained in the area, which have a good association with fluoride. Negative correlation is observed between fluoride and temperature, fluoride and magnesium, fluoride and potassium and poor correlation is observed between fluoride and chloride, fluoride and nitrate, fluoride and phosphates which rules out the possibility of anthropogenic source of the fluoride in the waters. Positive correlation between fluoride and iron, indicates that the presence of fluoride in the water is as a result of dissolution of biotite within the host rock (Basalt).