期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Retrospective Analysis of External Quality Assessment Data of Humoral (Except Feces) Morphology in Guangxi from 2010 to 2022
1
作者 Ciying XIAO Xiaochun LIU +3 位作者 Juan TANG Hongying ZHAO Xiangyang ZHOU Shengzhou NONG 《Medicinal Plant》 CAS 2023年第2期107-112,共6页
[Objectives] The study aims to improve the ability of inspectors to recognize humoral morphology and provide data reference for the improvement of EQA work of humoral morphology by Guangxi Clinical Laboratory Center. ... [Objectives] The study aims to improve the ability of inspectors to recognize humoral morphology and provide data reference for the improvement of EQA work of humoral morphology by Guangxi Clinical Laboratory Center. [Methods] A retrospective analysis was made on the EQA of humoral morphology by Guangxi Clinical Laboratory Center from 2010 to 2022, and the number of participating laboratories, the rate of return, sample types and maps of EQA of humoral morphology such as urine sediment, vaginal secretions and so on(except feces), and the reasons for the high error rate of the results of the participating laboratories were analyzed. [Results] The number of laboratories participating in the assessment of humoral morphology increased from 98 in 2010 to 371 in 2022. Except for 2011(90.98%), the rate of return was more than 94%, and the highest rate of return was up to 100%. A total of 119 pictures of EQA of humoral morphology were studied, including 101 urine sediment smears, 13 vaginal secretions smears and 5 other smears. The types of specimens were relatively comprehensive. The distribution of the maps was basically reasonable. The urinary sediment was mainly composed of crystalline salts, followed by tubes, and cells and fungi ranked third. The coverage was relatively complete. The error rate of return results from high to low were bacteria(error rate was equal to 40%), tubes and crystalline salts(error rate was close to 29%), and cells and fungi(error rate was about 14%). The main cases with high error rate of return results are as follows: the difference between different tubes was not clear, and the diversity of crystal morphology was not understood enough;the phase division of cells in the same system was wrong. [Conclusions] The analysis and summary of the reasons for the high error rate of the data and results of Guangxi's EQA of humoral morphology is helpful for laboratory physicians to improve their awareness of morphological examination and identify clearly the error type and blurred concept, and lays a foundation for Guangxi Clinical Laboratory Center to carry out EQA of humoral morphology more specifically. 展开更多
关键词 Humoral morphology External quality assessment Retrospective analysis
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部