Short-Term Wind Power Prediction Using Fuzzy Clustering and Support Vector Regression 被引量:3
1
作者 In-Yong Seo Bok-Nam Ha +3 位作者 Sung-Woo Lee Moon-Jong Jang Sang-Ok Kim Seong-Jun Kim 《Journal of Energy and Power Engineering》 2012年第10期1605-1610,共6页
A sustainable production of electricity is essential for low carbon green growth in South Korea. The generation of wind power as renewable energy has been rapidly growing around the world. Undoubtedly, wind energy is ... A sustainable production of electricity is essential for low carbon green growth in South Korea. The generation of wind power as renewable energy has been rapidly growing around the world. Undoubtedly, wind energy is unlimited in potential. However due to its own intermittency and volatility, there are difficulties in the effective harvesting of wind energy and the integration of wind power into the current electric power grid. To cope with this, many works have been done for wind speed and power forecasting. In this paper, an SVR (support vector regression) using FCM (Fuzzy C-Means) is proposed for wind speed forecasting. This paper describes the design of an FCM based SVR to increase the prediction accuracy. Proposed model was compared with ordinary SVR model using balanced and unbalanced test data. Also, multi-step ahead forecasting result was compared. Kernel parameters in SVR are adaptively determined in order to improve forecasting accuracy. An illustrative example is given by using real-world wind farm dataset. According to the experimental results, it is shown that the proposed method provides better forecasts of wind power. 展开更多
关键词 Support vector regression KERNEL fuzzy clustering wind power prediction.
下载PDF
Multi-Response Variable Optimization in Sensor Drift Monitoring System Using Support Vector Regression
2
作者 In-Yong Seo Bok-Nam Ha Won Nam Koong 《通讯和计算机(中英文版)》 2012年第7期752-758,共7页
关键词 支持向量回归 传感器漂移 变量优化 监控系统 传感器信号 灵敏度 正常运行 安全操作
下载PDF
A Simulation Environment for Intrusion Detection System in IEC 61850 Based Substation Automation System
3
作者 YooJin Kwon Seongho Ju Yonghun Lim 《Computer Technology and Application》 2013年第7期335-340,共6页
Greater complexity and interconnectivity across systems embracing electrical power technologies has meant that cyber-security issues have attracted significant attention. In this paper a simulation environment for int... Greater complexity and interconnectivity across systems embracing electrical power technologies has meant that cyber-security issues have attracted significant attention. In this paper a simulation environment for intrusion detection system in IEC 61850 standard-based substation automation system is provided to test simulated attacks on IEDs (intelligent electronic devices). Intrusion detection is the process of detecting malicious attacker, so it is an effective and mature security mechanism to protect electrical facility. However, it is not harnessed when securing IEC 61850 automated substation. To prove the detection capability of the system testing environment was developed to analyze and test attacks simulated with different test cases. It shows that the simulation environment works accordingly to various network traffic scenarios and eventually proves the functionality of intrusion detection system to be later deployed in the real IEC 61850 based substation automation system site. 展开更多
关键词 IEC 61850 substation automation system simulation environment.
下载PDF
Development of Fault Management Dispatcher Training Simulator for TDAS in Korea
4
作者 In-Yong Seo Sang-Ok Kim Bok-Nam Ha 《Engineering(科研)》 2013年第1期7-12,共6页
A fault management dispatcher training simulator for large-scale Distribution Automation System (TDAS) is developed to train operators in distribution control center. This simulator is composed of independent simulati... A fault management dispatcher training simulator for large-scale Distribution Automation System (TDAS) is developed to train operators in distribution control center. This simulator is composed of independent simulation server and operator consoles and can be used for network analysis, network operation, fault management and evaluation. TDAS DB is duplicated online to the simulation server keeping the data security. The system can model distribution network penetrated with distributed generations (DG) using the real data from the TDAS DB. Network fault scenarios are automatically generated by calculating fault current and generating fault indicators. Also, manual entry of cry wolf alarm is available. Moreover, operation solution for scenario of fault isolation and service restoration is generated automatically so that trainee can check their operation result. Operator actions during training session are saved and can be played back as well as displayed on one-line diagram pictures. 展开更多
关键词 Distribution AUTOMATION System FAULT Management DISPATCHER TRAINING SIMULATOR Distributed GENERATION
下载PDF
A Study on the Testing Procedures of IEC 61850 Based Transformer Protective lED
5
作者 N.H. Lee B.T. Jang Y.H. Kim Y.H. An J.Y. Han E.B. Shim 《Journal of Energy and Power Engineering》 2010年第11期58-62,共5页
Korea Electric Power Corporation in charge of the power IT project "Development of Prototype for Advanced Substation Automation System based on the Digital Control Technology", is performing the verification of perf... Korea Electric Power Corporation in charge of the power IT project "Development of Prototype for Advanced Substation Automation System based on the Digital Control Technology", is performing the verification of performance of the substation automation system based on IEC 61850. In order to verify a transformer protective lED that might be operating in substation automation system, the new standardized document and procedures are required in the aspect of the utility like KEPCO. But there is nothing to describe systematically how to verify IEC 6 1850 based lED in the system environment except an individual IED testing way. This paper will present the substation automation system based ways and procedures to verify the protective function of the IED using UML (Unified Modeling Language). 展开更多
关键词 IED conformance testing IEC61850 substation automation testing procedure.
下载PDF
Design of ADCS for Efficient Meter Data Collection and Management
6
作者 Nam-Joon Jung II-Kwon Yang +2 位作者 Seung-Hwan Choi Chang-Hun Chae Young-Taek Jin 《Journal of Energy and Power Engineering》 2012年第6期993-998,共6页
ADCS (automated data collection system) is the element of MDMS (meter data management system) and a module in charge of collecting the data from DCUs (data collection units) or meters in AMI (advanced metering ... ADCS (automated data collection system) is the element of MDMS (meter data management system) and a module in charge of collecting the data from DCUs (data collection units) or meters in AMI (advanced metering infrastructure)-based interactive two-way communications infrastructure. In this study, ADCS's functions for K-AMI (Korean Advanced Metering Infrastructure) were analyzed and the logical design of ADCS which is suitable for the requirements was suggested. A massive data collection and management functions was defined as very important functions of ADCS to meet optimal data processing mechanism. ADCS was designed for support about the fuctions of data collection and transfer, large capacity data processing, interactive services, parallel processing, etc.. Also, ADCS has roles of protocols exchange and gateway for service support in addition to data collection in AMI environment. 展开更多
关键词 AMI MDMS ADCS DCU smart metering.
下载PDF
Short Term Wind Power Prediction Using Wavelet Transform and ARIMA
7
作者 In-Yong Seo Bok-Nam Hat +3 位作者 Sang-Ok Kin Won Nam-Koong Dong-Wan Seo Seong-JunKim 《Journal of Energy and Power Engineering》 2012年第11期1786-1790,共5页
A sustainable production of electricity is essential for low carbon green growth in South Korea. Although wind energy is unlimited in potential, both intermittency and volatility should be tackled for smart grid integ... A sustainable production of electricity is essential for low carbon green growth in South Korea. Although wind energy is unlimited in potential, both intermittency and volatility should be tackled for smart grid integration in future. To cope with this, many works have been done for wind speed and power forecasting. It is shown that statistical techniques are useful for short-term forecasting of wind power. This paper presents a statistical wind speed forecasting. The wavelet decomposition is employed as a de-noising technique. An illustration will be given by real-world dataset. According to the result, the MAD (mean absolute deviation) is improved as much as 10%. 展开更多
关键词 Wind speed forecasting autoreressive model wavelet decomnosition mean absolute deviation.
下载PDF
CIM Model Extension for Intelligent DAS of Smart Power Grid in Korea
8
作者 In-Yong Seo Bok-Nam Ha +2 位作者 Sang-Ok Kim Dong-Uk Heo Hee-Joo Lee 《Journal of Energy and Power Engineering》 2012年第8期1328-1334,共7页
The CIM (common information model) is an abstract information model that can be used to model an electrical network and various equipments used on the network. By using a common model, utilities and vendors can redu... The CIM (common information model) is an abstract information model that can be used to model an electrical network and various equipments used on the network. By using a common model, utilities and vendors can reduce their integration costs, which should allow more resources to be applied toward increased functionality for managing and optimizing the electrical system. As a part of smart grid, the SPG (smart power grid) was built on Jeju Island. The SPG consists of IDAS (intelligent distribution automation system), substation automation system, intelligent transmission system, and active telemetrics system. To integrate these systems which have different operating systems and platforms CIM standard was used. But IDAS has many functions and advanced algorithms not defined in CIM. In this paper, the authors introduce how to develop and extend the CIM model for managing the IDAS. 展开更多
关键词 Battery common information model distribution automation system smart grid.
下载PDF