期刊文献+
共找到484篇文章
< 1 2 25 >
每页显示 20 50 100
Millisecond dynamics of colloidal suspension studied by X-ray photon correlation spectroscopy at the Shanghai Synchrotron Radiation Facility 被引量:1
1
作者 Chen-Hui Cui Zi-Mu Zhou +7 位作者 Lin-Feng Wei Song-Lin Li Feng Tian Xiu-Hong Li Zhi Guo Yi-Hui Xu Huai-Dong Jiang Ren-Zhong Tai 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第1期1-9,共9页
X-ray photon correlation spectroscopy(XPCS)has emerged as a powerful tool for probing the nanoscale dynamics of soft condensed matter and strongly correlated materials owing to its high spatial resolution and penetrat... X-ray photon correlation spectroscopy(XPCS)has emerged as a powerful tool for probing the nanoscale dynamics of soft condensed matter and strongly correlated materials owing to its high spatial resolution and penetration capabilities.This technique requires high brilliance and beam coherence,which are not directly available at modern synchrotron beamlines in China.To facilitate future XPCS experiments,we modified the optical setup of the newly commissioned BL10U1 USAXS beamline at the Shanghai Synchrotron Radiation Facility(SSRF).Subsequently,we performed XPCS measurements on silica suspensions in glycerol,which were opaque owing to their high concentrations.Images were collected using a high frame rate area detector.A comprehensive analysis was performed,yielding correlation functions and several key dynamic parameters.All the results were consistent with the theory of Brownian motion and demonstrated the feasibility of XPCS at SSRF.Finally,by carefully optimizing the setup and analyzing the algorithms,we achieved a time resolution of 2 ms,which enabled the characterization of millisecond dynamics in opaque systems. 展开更多
关键词 XPCS SSRF Silica suspension GLYCEROL Brownian motion Millisecond dynamics
下载PDF
A new horizon for neuroscience:terahertz biotechnology in brain research
2
作者 Zhengping Pu Yu Wu +2 位作者 Zhongjie Zhu Hongwei Zhao Donghong Cui 《Neural Regeneration Research》 SCIE CAS 2025年第2期309-325,共17页
Terahertz biotechnology has been increasingly applied in various biomedical fields and has especially shown great potential for application in brain sciences.In this article,we review the development of terahertz biot... Terahertz biotechnology has been increasingly applied in various biomedical fields and has especially shown great potential for application in brain sciences.In this article,we review the development of terahertz biotechnology and its applications in the field of neuropsychiatry.Available evidence indicates promising prospects for the use of terahertz spectroscopy and terahertz imaging techniques in the diagnosis of amyloid disease,cerebrovascular disease,glioma,psychiatric disease,traumatic brain injury,and myelin deficit.In vitro and animal experiments have also demonstrated the potential therapeutic value of terahertz technology in some neuropsychiatric diseases.Although the precise underlying mechanism of the interactions between terahertz electromagnetic waves and the biosystem is not yet fully understood,the research progress in this field shows great potential for biomedical noninvasive diagnostic and therapeutic applications.However,the biosafety of terahertz radiation requires further exploration regarding its two-sided efficacy in practical applications.This review demonstrates that terahertz biotechnology has the potential to be a promising method in the field of neuropsychiatry based on its unique advantages. 展开更多
关键词 biological effect brain NEURON NEUROPSYCHIATRY NEUROSCIENCE non-thermal effect terahertz imaging terahertz radiation terahertz spectroscopy terahertz technology
下载PDF
A seven-crystal spectrometer for high-energy resolution X-ray spectroscopy at Shanghai Synchrotron Radiation Facility
3
作者 Bing-Bao Mei Liang-Xin Wang +6 位作者 Song-Qi Gu Xiao-Zhi Su Shuo Zhang Yao Wei Jing-Yuan Ma Zheng Jiang Fei Song 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第9期82-91,共10页
A Johann-type X-ray spectrometer was successfully developed at the hard X-ray branch(in-vacuum undulator with a 24-mm periodic length)of the energy material beamline(E-line)at the Shanghai Synchrotron Radiation Facili... A Johann-type X-ray spectrometer was successfully developed at the hard X-ray branch(in-vacuum undulator with a 24-mm periodic length)of the energy material beamline(E-line)at the Shanghai Synchrotron Radiation Facility(SSRF).This spectrometer was utilized to implement X-ray emission spectroscopy(XES),high-energy resolution fluorescence-detected X-ray absorption spectroscopy(HERFD-XAS),and resonant inelastic X-ray scattering.Seven spherically bent crystals were positioned on the respective vertical 500-mm-diameter Rowland circles,adopting an area detector to increase the solid angle to 1.75%of 4πsr,facilitating the study of low-concentrate systems under complex reaction conditions.Operated under the atmosphere pressure,the spectrometer covers the energy region from 3.5 to 18 keV,with the Bragg angle ranging from 73°to 86°during vertical scanning.It offers a promised energy resolution of sub-eV(XES)and super-eV(HERFD-XAS).Generally,these comprehensive core-level spectroscopy methods based on hard X-rays at the E-line with an extremely high photon flux can meet the crucial requirements of a green energy strategy.Moreover,they provide substantial support for scientific advances in fundamental research. 展开更多
关键词 X-ray emission spectroscopy High-energy-resolution X-ray spectrometer Johann geometry Energy materials SSRF
下载PDF
SAPT:a synchrotron-based proton therapy facility in Shanghai 被引量:2
4
作者 Man-Zhou Zhang De-Ming Li +45 位作者 Li-Ren Shen Hai-Rong Zhang Zhi-Ling Chen Han-Wen Du Ming Gu Rui Li De-Kang Liu Yue-Hu Pu Jun-Feng Yu Jian-Feng Chen Chu Chen Chun-Long Guo Hao Guo Ge-Yang Jiang Zhi-Qiang Jiang Lin Jin Wen-Jing Li Xiu-Fang Li Ye Lin Ming Liu Yong-Hao Liu Ya-Juan Liu Ming Lv Qing-Ru Mi Lian-Hua Ouyang Wei-Guo Shi Hang Shu Qi-Sheng Tang Kun Wang Zhi-Shan Wang Jun Wu Xiao-Bing Wu Jia-Qiang Xu Wen-Zhen Xu Chong-Xian Yin Cheng Yu Ren-Xian Yuan Qi-Bing Yuan Hai-Qun Zhang Miao Zhang Wen-Zhi Zhang Li-Ying Zhao Wei-Min Zhou Shou-Xian Fang Xi-Dong Sun Zhen-Tang Zhao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第10期36-46,共11页
Because of its excellent dose distribution,proton therapy is becoming increasingly popular in the medical application of cancer treatment.A synchrotron-based proton therapy facility was designed and constructed in Sha... Because of its excellent dose distribution,proton therapy is becoming increasingly popular in the medical application of cancer treatment.A synchrotron-based proton therapy facility was designed and constructed in Shanghai.The synchrotron,beam delivery system,and other technical systems were commissioned and reached their expected performances.After a clinical trial of 47 patients was finished,the proton therapy facility obtained a registration certificate from the National Medical Products Administration.The characteristics of the accelerator and treatment systems are described in this article. 展开更多
关键词 Proton therapy SYNCHROTRON Slow extraction GANTRY Beam delivery system
下载PDF
BL02U1:the relocated macromolecular crystallography beamline at the Shanghai Synchrotron Radiation Facility 被引量:1
5
作者 Ke Liu Huan Zhou +9 位作者 Qin Xu Hua‑Ting Kong Kun‑Hao Zhang Wei‑Wei Wang Min‑Jun Li Zhi‑Jun Wang Qiang‑Yan Pan Xing‑Ya Wang Feng Yu Qi‑Sheng Wang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第12期146-155,共10页
Macromolecular crystallography beamline BL17U1 at the Shanghai Synchrotron Radiation Facility has been relocated,upgraded,and given a new ID(BL02U1).It now delivers X-rays in the energy range of 6–16 keV,with a focus... Macromolecular crystallography beamline BL17U1 at the Shanghai Synchrotron Radiation Facility has been relocated,upgraded,and given a new ID(BL02U1).It now delivers X-rays in the energy range of 6–16 keV,with a focused beam of 11.6μm×4.8μm and photon flux greater than 1012 phs/s.The high credibility and stability of the beam and good timing synchronization of the equipment significantly improve the experimental efficiency.Since June 2021,when it officially opened to users,over 4200 h of beamtime have been provided to over 200 research groups to collect data at the beamline.Its good performance and stable operation have led to the resolution of several structures based on data collected at the beamline. 展开更多
关键词 Macromolecular crystallography beamline Shanghai Synchrotron Radiation Facility BL02U1
下载PDF
The biosafety level-2 macromolecular crystallography beamline(BL10U2)at the Shanghai Synchrotron Radiation Facility 被引量:1
6
作者 Qin Xu Hua‑Ting Kong +10 位作者 Ke Liu Huan Zhou Kun‑Hao Zhang Wei‑Wei Wang Min‑Jun Li Qiang‑Yan Pan Xing‑Ya Wang Yu‑Zhu Wang Feng Yu Xing‑Yu Gao Qi‑Sheng Wang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第12期251-263,共13页
BL10U2 is an undulator-based macromolecular crystallography(MX)beamline located at the 3.5-GeV Shanghai Synchrotron Radiation Facility.BL10U2 is specifically designed for conducting routine and biosafety level-2(BSL-2... BL10U2 is an undulator-based macromolecular crystallography(MX)beamline located at the 3.5-GeV Shanghai Synchrotron Radiation Facility.BL10U2 is specifically designed for conducting routine and biosafety level-2(BSL-2)MX experiments utilizing high-flux tunable X-rays with energies from 7 to 18 keV,providing a beam spot size of 20μm(horizontal)×10μm(vertical)at the sample point.Certification by the Shanghai Pudong Municipal Health Commission confirmed the capability to perform BSL-2 MX experiments.The beamline is currently equipped with an Eiger X 16 M detector and two newly developed in-house high-precision diffractometers that can be switched to perform conventional or in situ crystal diffraction experiments.An automatic sample changer developed in-house allows fast sample exchange in less than 30 s,supporting high-throughput MX experimentation and rapid crystal screening.Data collection from both the diffractometer and detector was controlled by an in-house developed data collection software(Finback)with a user-friendly interface for convenient operation.This study presents a comprehensive overview of the facilities,experimental methods,and performance characteristics of the BL10U2 beamline. 展开更多
关键词 Shanghai Synchrotron Radiation Facility BSL-2 MX beamline BL10U2
下载PDF
Li-promoted C_(3)N_(4) catalyst for efficient isomerization of glucose into fructose at 50℃ in water 被引量:1
7
作者 Wang Liu Yanfei Zhang +5 位作者 Mengya Sun Xinpeng Zhao Shenggang Li Xinqing Chen Liangshu Zhong Lingzhao Kong 《Green Energy & Environment》 SCIE EI CAS CSCD 2024年第9期1419-1426,共8页
Efficient and selective glucose-to-fructose isomerization is a crucial step for production of oxygenated chemicals derived from sugars,which is usually catalyzed by base or Lewis acid heterogeneous catalyst.However,hi... Efficient and selective glucose-to-fructose isomerization is a crucial step for production of oxygenated chemicals derived from sugars,which is usually catalyzed by base or Lewis acid heterogeneous catalyst.However,high yield and selectivity of fructose cannot be simultaneously obtained under mild conditions which hamper the scale of application compared with enzymatic catalysis.Herein,a Li-promoted C_(3)N_(4) catalyst was exploited which afforded an excellent fructose yield(40.3 wt%)and selectivity(99.5%)from glucose in water at 50℃,attributed to the formation of stable Li–N bond to strengthen the basic sites of catalysts.Furthermore,the so-formed N_(6)–Li–H_(2)O active site on Li–C_(3)N_(4) catalyst in aqueous phase changes the local electronic structure and strengthens the deprotonation process during glucose isomerization into fructose.The superior catalytic performance which is comparable to biological pathway suggests promising applications of lithium containing heterogeneous catalyst in biomass refinery. 展开更多
关键词 GLUCOSE FRUCTOSE ISOMERIZATION Li–C_(3)N_(4) Density functional theory calculations
下载PDF
Dealuminated Hβ zeolite for selective conversion of fructose to furfural and formic acid 被引量:1
8
作者 Rui Li Qixuan Lin +3 位作者 Junli Ren Xiaobao Yang Yingxiong Wang Lingzhao Kong 《Green Energy & Environment》 SCIE EI CAS CSCD 2024年第2期311-320,共10页
The fructose-to-furfural transformation is facing major challenges in the selectivity and high efficiency. Herein, we have developed a simple and effective approach for the selective conversion of fructose to furfural... The fructose-to-furfural transformation is facing major challenges in the selectivity and high efficiency. Herein, we have developed a simple and effective approach for the selective conversion of fructose to furfural using Hβ zeolite modified by organic acids for dealuminization to regulate its textural and acidic properties. It was found that citric acid-dealuminized Hβ zeolite possessed high specific surface areas, wide channels and high Brønsted acid amount, which facilitated the selective conversion of fructose to furfural with a maximum yield of 76.2% at433 K for 1 h in the γ-butyrolactone(GBL)-H_(2)O system, as well as the concomitant formation of 83.0% formic acid. The^(13)C-isotope labelling experiments and the mechanism revealed that the selective cleavage of C1–C2 or C5–C6 bond on fructose was firstly occurred to form pentose or C5 intermediate by weak Brønsted acid, which was then dehydrated to furfural by strong Brønsted acid. Also this dealuminized Hβ catalyst showed the great recycling performance and was active for the conversion of glucose and mannose. 展开更多
关键词 FRUCTOSE Dealuminated-Hb zeolite Selective conversion FURFURAL
下载PDF
Building Feedback-Regulation System Through Atomic Design for Highly Active SO_(2)Sensing 被引量:1
9
作者 Xin Jia Panzhe Qiao +8 位作者 Xiaowu Wang Muyu Yan Yang Chen Bao-Li An Pengfei Hu Bo Lu Jing Xu Zhenggang Xue Jiaqiang Xu 《Nano-Micro Letters》 SCIE EI CAS CSCD 2024年第7期343-357,共15页
Reasonably constructing an atomic interface is pronouncedly essential for surface-related gas-sensing reaction.Herein,we present an ingen-ious feedback-regulation system by changing the interactional mode between sing... Reasonably constructing an atomic interface is pronouncedly essential for surface-related gas-sensing reaction.Herein,we present an ingen-ious feedback-regulation system by changing the interactional mode between single Pt atoms and adjacent S species for high-efficiency SO_(2)sensing.We found that the single Pt sites on the MoS_(2)surface can induce easier volatiliza-tion of adjacent S species to activate the whole inert S plane.Reversely,the activated S species can provide a feedback role in tailoring the antibonding-orbital electronic occupancy state of Pt atoms,thus creating a combined system involving S vacancy-assisted single Pt sites(Pt-Vs)to synergistically improve the adsorption ability of SO_(2)gas molecules.Further-more,in situ Raman,ex situ X-ray photoelectron spectroscopy testing and density functional theory analysis demonstrate the intact feedback-regulation system can expand the electron transfer path from single Pt sites to whole Pt-MoS_(2)supports in SO_(2)gas atmosphere.Equipped with wireless-sensing modules,the final Pt1-MoS_(2)-def sensors array can further realize real-time monitoring of SO_(2)levels and cloud-data storage for plant growth.Such a fundamental understanding of the intrinsic link between atomic interface and sensing mechanism is thus expected to broaden the rational design of highly effective gas sensors. 展开更多
关键词 Feedback-regulation system Atomic interface SO_(2)sensor Single-atom sensing mechanism Intelligent-sensing array
下载PDF
Ultrahard X-ray multifunctional application beamline at the SSRF
10
作者 Ke Yang Zhao-Hui Dong +4 位作者 Chun-Yin Zhou Zi-Long Zhao Dong-Xu Liang Sai-Chao Cao Ai-Guo Li 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第6期14-25,共12页
The ultrahard X-ray multifunctional application beamline(BL12SW)is a phase-II beamline project at the Shanghai Syn-chrotron Radiation Facility.The primary X-ray techniques used at the beamline are high-energy X-ray di... The ultrahard X-ray multifunctional application beamline(BL12SW)is a phase-II beamline project at the Shanghai Syn-chrotron Radiation Facility.The primary X-ray techniques used at the beamline are high-energy X-ray diffraction and imaging using white and monochromatic light.The main scientific objectives of ultrahard X-ray beamlines are focused on two research areas.One is the study of the structural properties of Earth’s interior and new materials under extreme high-temperature and high-pressure conditions,and the other is the characterization of materials and processes in near-real service environments.The beamline utilizes a superconducting wiggler as the light source,with two diamond windows and SiC discs to filter out low-energy light(primarily below 30 keV)and a Cu filter assembly to control the thermal load entering the subsequent optical components.The beamline is equipped with dual monochromators.The first was a meridional bending Laue monochromator cooled by liquid nitrogen,achieving a full-energy coverage of 30-162 keV.The second was a sagittal bending Laue monochromator installed in an external building,providing a focused beam in the horizontal direction with an energy range of 60-120 keV.There were four experimental hutches:two large-volume press experimental hutches(LVP1 and LVP2)and two engineering material experimental hutches(ENG1 and ENG2).Each hutch was equipped with various near-real service conditions to satisfy different requirements.For example,LVP1 and LVP2 were equipped with a 200-ton DDIA press and a 2000-ton dual-mode(DDIA and Kawai)press,respectively.ENG1 and ENG2 provide in situ tensile,creep,and fatigue tests as well as high-temperature conditions.Since June 2023,the BL12SW has been in trial operation.It is expected to officially open to users by early 2024. 展开更多
关键词 Shanghai Synchrotron Radiation Facility Ultrahard X-ray High energy diffraction High energy imaging Engineering materials Earth science
下载PDF
Overview of SSRF phase-Ⅱ beamlines
11
作者 Ren‑Zhong Tai Zhen‑Tang Zhao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第8期48-57,共10页
The SSRF phase-Ⅱ beamline project was launched in 2016. Its major goal was to establish a systematic state-of-the-art experimental facility for third-generation synchrotron radiation to solve problems in cutting-edge... The SSRF phase-Ⅱ beamline project was launched in 2016. Its major goal was to establish a systematic state-of-the-art experimental facility for third-generation synchrotron radiation to solve problems in cutting-edge science and technology.Currently, the construction is fully completed. All 16 newly built beamlines with nearly 60 experimental methods passed acceptance testing by the Chinese Academy of Sciences and are in operation. 展开更多
关键词 SSRF phase-Ⅱbeamline project Accelerator upgrade User laboratory User data center Beamline technique support
下载PDF
Development of a high-repetition-rate lumped-inductance kicker magnet prototype for the beam switchyard of SHINE
12
作者 Yong-Fang Liu Rui-Ping Wang +6 位作者 Jin Tong Bo Zhang Si Chen Qi-Bing Yuan Hai-Xiao Deng Ming Gu Bo Liu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第2期20-31,共12页
The Shanghai high-repetition-rate X-ray free-electron laser and extreme light facility(SHINE)operates at a maximum repetition rate of 1 MHz.Kicker magnets are key components that distribute electron bunches into three... The Shanghai high-repetition-rate X-ray free-electron laser and extreme light facility(SHINE)operates at a maximum repetition rate of 1 MHz.Kicker magnets are key components that distribute electron bunches into three different undulator lines in a bunch-by-bunch mode.The kicker field width must be less than the time interval between bunches.A lumpedinductance kicker prototype was developed using a vacuum chamber with a single-turn coil.The full magnetic field strength was 0.005 T.This paper presents the requirements,design considerations,design parameters,magnetic field calculations,and measurements of the kicker magnets.The relevant experimental results are also presented.The pulse width of the magnetic field was approximately 600 ns,and the maximum operation repetition rate was 1 MHz.The developed kicker satisfies the requirements for the SHINE project.Finally,numerous recommendations for the future optimization of kicker magnets are provided. 展开更多
关键词 X-ray free-electron laser Kicker magnet Beam switchyard High repetition rate Ni-Zn ferrites
下载PDF
The dynamics beamline at SSRF
13
作者 Zhen Liu Li-Hua Wang +6 位作者 Yong Jiang Ya-Jun Tong Hua-Chun Zhu Te Ji Min Chen Zheng Jiang Xiang-Jun Wei 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第9期56-67,共12页
The dynamics beamline(D-Line),which combines synchrotron radiation infrared spectroscopy(SR-IR)and energy-disper-sive X-ray absorption spectroscopy(ED-XAS),is the first beamline in the world to realize concurrent ED-X... The dynamics beamline(D-Line),which combines synchrotron radiation infrared spectroscopy(SR-IR)and energy-disper-sive X-ray absorption spectroscopy(ED-XAS),is the first beamline in the world to realize concurrent ED-XAS and SR-IR measurements at the same sample position on a millisecond time-resolved scale.This combined technique is effective for investigating rapid structural changes in atoms,electrons,and molecules in complicated disorder systems,such as those used in physics,chemistry,materials science,and extreme conditions.Moreover,ED-XAS and SR-IR can be used independently in the two branches of the D-Line.The ED-XAS branch is the first ED-XAS beamline in China,which uses a tapered undulator light source and can achieve approximately 2.5×10^(12)photons/s·300 eV BW@7.2 keV at the sample position.An exchange-able polychromator operating in the Bragg-reflection or Laue-transmission configuration is used in different energy ranges to satisfy the requirements for beam size and energy resolution.The focused beam size is approximately 3.5μm(H)×21.5μm(V),and the X-ray energy range is 5–25 keV.Using one-and two-dimensional position-sensitive detectors with frame rates of up to 400 kHz enables time resolutions of tens of microseconds to be realized.Several distinctive techniques,such as the concurrent measurement of in situ ED-XAS and infrared spectroscopy,time-resolved ED-XAS,high-pressure ED-XAS,XMCD,and pump-probe ED-XAS,can be applied to achieve different scientific goals. 展开更多
关键词 ED-XAS SR-IR TIME-RESOLVED D-line SSRF
下载PDF
The SLEGS beamline of SSRF
14
作者 Long-Xiang Liu Hong-Wei Wang +4 位作者 Gong-Tao Fan Hang-Hua Xu Yue Zhang Zi-Rui Hao Ai-Guo Li 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第7期20-30,共11页
The Shanghai Laser Electron Gamma Source(SLEGS, located in BL03SSID) beamline at the Shanghai Synchrotron Radiation Facility(SSRF) is a Laser Compton Scattering(LCS) gamma source used for the investigation of nuclear ... The Shanghai Laser Electron Gamma Source(SLEGS, located in BL03SSID) beamline at the Shanghai Synchrotron Radiation Facility(SSRF) is a Laser Compton Scattering(LCS) gamma source used for the investigation of nuclear structure, which is in extensive demand in fields such as nuclear astrophysics, nuclear cluster structure, polarization physics, and nuclear energy. The beamline is based on the inverse Compton scattering of 10640 nm photons on 3.5 GeV electrons and a gamma source with variable energy by changing the scattering angle from 20° to 160°. γ rays of 0.25-21.1 MeV can be extracted by the scheme consisting of the interaction chamber, coarse collimator, fine collimator, and attenuator. The maximum photon flux for 180° is approximately 10~7 photons/s at the target at 21.7 MeV, with a 3-mm-diameter beam. The beamline was equipped with four types of spectrometers for experiments in( γ,γ'),( γ,n),( γ,p), and( γ,α). At present, Nuclear Resonance Fluorescence(NRF) spectrometry, Flat-Efficiency neutron Detector(FED) spectrometry, neutron Time-Of-Flight(TOF) spectrometry, and Light-Charged Particle(LCP) spectrometry methods have been developed. 展开更多
关键词 Shanghai Synchrotron Radiation Facility SLEGS Nuclear astrophysics Nuclear structure
下载PDF
Fast X-ray imaging beamline at SSRF
15
作者 Ke Li Hong-Lan Xie +5 位作者 Ya-Nan Fu Fei-Xiang Wang Guo-Hao Du Jian-Feng ji Biao Deng Ti-Qiao Xiao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第9期68-81,共14页
The fast X-ray imaging beamline(BL16U2)at Shanghai Synchrotron Radiation Facility(SSRF)is a new beamline that provides X-ray micro-imaging capabilities across a wide range of time scales,spanning from 100 ps toμs and... The fast X-ray imaging beamline(BL16U2)at Shanghai Synchrotron Radiation Facility(SSRF)is a new beamline that provides X-ray micro-imaging capabilities across a wide range of time scales,spanning from 100 ps toμs and ms.This beamline has been specifically designed to facilitate the investigation of a wide range of rapid phenomena,such as the deformation and failure of materials subjected to intense dynamic loads.In addition,it enables the study of high-pressure and high-speed fuel spray processes in automotive engines.The light source of this beamline is a cryogenic permanent magnet undulator(CPMU)that is cooled by liquid nitrogen.This CPMU can generate X-ray photons within an energy range of 8.7-30 keV.The beamline offers two modes of operation:monochromatic beam mode with a liquid nitrogen-cooled double-crystal monochromator(DCM)and pink beam mode with the first crystal of the DCM out of the beam path.Four X-ray imaging methods were implemented in BL16U2:single-pulse ultrafast X-ray imaging,microsecond-resolved X-ray dynamic imaging,millisecond-resolved X-ray dynamic micro-CT,and high-resolution quantitative micro-CT.Furthermore,BL16U2 is equipped with various in situ impact loading systems,such as a split Hopkinson bar system,light gas gun,and fuel spray chamber.Following the completion of the final commissioning in 2021 and subsequent trial operations in 2022,the beamline has been officially available to users from 2023. 展开更多
关键词 Multiple time-scale X ray imaging Single-pulse X ray imaging Dynamic 2D imaging Dynamic micro-CT
下载PDF
Surface diffraction beamline at the SSRF
16
作者 Yue-Liang Gu Xu Zheng +6 位作者 Xing-Min Zhang Bin Zhao Guang-Zhi Yin Da-Ming Zhu Yuan-He Sun Xing-Yu Gao Xiao-Long Li 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第7期47-57,共11页
BL02U2 of the Shanghai Synchrotron Radiation Facility is a surface diffraction beamline with a photon flux of 5.5×10^(12) photons/s at 10 keV and a beam size of 160µm×80µm at the sample site.It is ... BL02U2 of the Shanghai Synchrotron Radiation Facility is a surface diffraction beamline with a photon flux of 5.5×10^(12) photons/s at 10 keV and a beam size of 160µm×80µm at the sample site.It is dedicated to studying surfaces(solid-vacuum,solid-gas)and interfaces(solid-solid,solid-liquid,and liquid-liquid)in nanoscience,condensed matter,and soft matter systems using various surface scattering techniques over an energy range of 4.8-28 keV with transmission and reflection modes.Moreover,BL02U2 has a high energy resolution,high angular resolution,and low beam divergence,which can provide excellent properties for X-ray diffraction experiments,such as grazing incident X-ray diffraction,X-ray reflectivity,crystal truncation rods,and liquid X-ray scattering.Diversity of in situ environments can also be provided for the samples studied.This paper describes the setup of the new beamline and its applications in various fields. 展开更多
关键词 Surface and interface BEAMLINE Surface diffraction MICROSTRUCTURE
下载PDF
Quick-scanning X-ray absorption fine structure beamline at SSRF
17
作者 Yu Chen Qian Gao +2 位作者 Zheng Jiang Jiong Li Shuo Zhang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第6期1-13,共13页
The layout and characteristics of the hard X-ray spectroscopy beamline(BL11B)at the Shanghai synchrotron radiation facility are described herein.BL11B is a bending-magnet beamline dedicated to conventional and millise... The layout and characteristics of the hard X-ray spectroscopy beamline(BL11B)at the Shanghai synchrotron radiation facility are described herein.BL11B is a bending-magnet beamline dedicated to conventional and millisecond-scale quick-scanning X-ray absorption fine structures.It is equipped with a cylindrical collimating mirror,a double-crystal monochromator comprising Si(111)and Si(311),a channel-cut quick-scanning Si(111)monochromator,a toroidal focusing mirror,and a high harmonics rejection mirror.It can provide 5-30 keV of X-rays with a photon flux of~5×10^(11)photons/s and an energy resolution of~1.31×10^(-4)at 10 keV.The performance of the beamline can satisfy the demands of users in the fields of catalysis,materials,and environmental science.This paper presents an overview of the beamline design and a detailed description of its performance and capabilities. 展开更多
关键词 Bending magnet beamline X-ray absorption fine structure Quick-scanning XAFS In situ Synchrotron radiation
下载PDF
BL03HB: a Laue microdiffraction beamline for both protein crystallography and materials science at SSRF
18
作者 Zhi-Jun Wang Si-Sheng Wang +5 位作者 Zheng-Huang Su Li Yu Yu-Zhu Wang Bo Sun Wen Wen Xing-Yu Gao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第7期68-78,共11页
A Laue microdiffraction beamline(BL03HB) was constructed at the Shanghai Synchrotron Radiation Facility(SSRF).This beamline features two consecutive focusing points in two different sectors within its end station, the... A Laue microdiffraction beamline(BL03HB) was constructed at the Shanghai Synchrotron Radiation Facility(SSRF).This beamline features two consecutive focusing points in two different sectors within its end station, the first dedicated to protein crystallography and the other tailored to materials science applications. Based on a superbend dipole magnet with a magnetic field of 2.29 T, a two-stage focusing design was implemented with two sets of Kirkpatrick-Baez mirrors to achieve a micro white beam as small as 4.2 μ m ×4.3 μ m at the first sector and 0.9 μ m ×1.3 μ m at the second sector in the standard beamline operation mode at SSRF. The X-ray microbeam in the two sectors can be easily switched between monochromatic and white beams by moving a four-bounce monochromator in or out of the light path, respectively. In the protein crystallography sector, white-beam Laue microdiffraction was demonstrated to successfully determine the structure of protein crystals from only a few images of diffraction data collected by a Pilatus 2 M area detector. In the materials science sector,the white-beam Laue diffraction was collected in a reflection geometry using another Pilatus 2 M area detector, which could map the microstructural distribution on the sample surface by scanning the samples. In general, the BL03HB beamline promotes the application of Laue microdiffraction in both protein crystallography and materials science. This paper presents a comprehensive overview of the BL03HB beamline, end station, and the first commission results. 展开更多
关键词 CRYSTALLOGRAPHY White-beam Laue microdiffraction BEAMLINE Synchrotron
下载PDF
Determining beam transverse absolute position by triangulation of multi-electrode signal phase differences
19
作者 Xing Yang Hong‑Shuang Wang +1 位作者 Yi‑Mei Zhou Yong‑Bin Leng 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第8期38-47,共10页
Accurate measurement of the transverse position of a beam is crucial in particle accelerators because it plays a key role in determining the beam parameters.Existing methods for beam-position measurement rely on the d... Accurate measurement of the transverse position of a beam is crucial in particle accelerators because it plays a key role in determining the beam parameters.Existing methods for beam-position measurement rely on the detection of image currents induced on electrodes or narrow-band wake field induced by a beam passing through a cavity-type structure.However,these methods have limitations.The indirect measurement of multiple parameters is computationally complex,requiring external calibration to determine the system parameters in advance.Furthermore,the utilization of the beam signal information is incomplete.Hence,this study proposes a novel method for measuring the absolute electron beam transverse position.By utilizing the geometric relationship between the center position of the measured electron beam and multiple detection electrodes and by analyzing the differences in the arrival times of the beam signals detected by these electrodes,the absolute transverse position of the electron beam crossing the electrode plane can be calculated.This method features absolute position measurement,a position sensitivity coefficient independent of vacuum chamber apertures,and no requirement for a symmetrical detector electrode layout.The feasibility of this method is validated through numerical simulations and beam experiments. 展开更多
关键词 Electron beam bunch-by bunch diagnostics Bunch position measurement Triangulation method Bunch phase Bunch-by-bunch Transverse position Pickup signal
下载PDF
Novel high-voltage cathode for aqueous zinc ion batteries:Porous K_(0.5)VOPO_(4)·1.5H_(2)O with reversible solid-solution intercalation and conversion storage mechanism
20
作者 Liyu Wang Mingliang Zhao +9 位作者 Xiaoyu Zhang Menghua Wu Yu Zong Yu Chen Xinliang Huang Mingjie Xing Xin Ning Wen Wen Daming Zhu Xiaochuan Ren 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第6期71-78,I0003,共9页
Cathode materials that possess high output voltage,as well as those that can be mass-produced using facile techniques,are crucial for the advancement of aqueous zinc-ion battery(ZIBs)applications,Herein,we present for... Cathode materials that possess high output voltage,as well as those that can be mass-produced using facile techniques,are crucial for the advancement of aqueous zinc-ion battery(ZIBs)applications,Herein,we present for the first time a new porous K_(0.5)VOPO_(4)·1.5H_(2)O polyanionic cathode(P-KIVP)with high output voltage(above 1.2 V)that can be manufactured at room temperature using straightforward coprecipitation and etching techniques.The P-KVP cathode experiences anisotropic crystal plane expansion via a sequential solid-solution intercalation and phase co nversion pathway throughout the Zn^(2+)storage process,as confirmed by in-situ synchrotron X-ray diffraction and ex-situ X-ray photoelectron spectroscopy.Similar to other layered vanadium-based polyanionic materials,the P-KVP cathode experiences a progressive decline in voltage during the cycle,which is demonstrated to be caused by the irreversible conversion into amorphous VO_(x).By introducing a new electrolyte containing Zn(OTF)_(2) to a mixed triethyl phosphate and water solution,it is possible to impede this irreversible conversion and obtain a high output voltage and longer cycle life by forming a P-rich cathode electrolyte interface layer.As a proof-of-concept,the flexible fiber-shaped ZIBs based on modified electrolyte woven into a fabric watch band can power an electronic watch,highlighting the application potential of P-KVP cathode. 展开更多
关键词 Aqueous zinc ion battery CATHODE Porous material High voltage platform In-situ synchrotron X-ray diffraction
下载PDF
上一页 1 2 25 下一页 到第
使用帮助 返回顶部