BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant bili...BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant biliary obstruction after endoscopic retrograde cholangiopancreatography(ERCP)failure.However,most of the studies that have assessed its efficacy and safety were small and hetero-geneous.Prior meta-analyses of six or fewer studies that were published 2 years ago were therefore underpowered to yield convincing evidence.AIM To update the efficacy and safety of ECE-LAMS for treatment of biliary ob-struction after ERCP failure.METHODS We searched PubMed,EMBASE,and Scopus databases from the inception of the ECE technique to May 13,2022.Primary outcome measure was pooled technical success rate,and secondary outcomes were pooled rates of clinical success,re-intervention,and adverse events.Meta-analysis was performed using a random-effects model following Freeman-Tukey double-arcsine transformation in R soft-ware(version 4.1.3).RESULTS Fourteen eligible studies involving 620 participants were ultimately included.The pooled rate of technical success was 96.7%,and clinical success was 91.0%.Adverse events were reported in 17.5%of patients.Overall reinter-vention rate was 7.3%.Subgroup analyses showed results were generally consistent.CONCLUSION ECE-LAMS has favorable success with acceptable adverse events in relieving biliary obstruction when ERCP is impossible.The consistency of results across most subgroups suggested that this is a generalizable approach.展开更多
基金The authors have read the PRISMA 2009 Checklist,and the manuscript was prepared and revised according to the PRISMA 2009 Checklist.
文摘BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant biliary obstruction after endoscopic retrograde cholangiopancreatography(ERCP)failure.However,most of the studies that have assessed its efficacy and safety were small and hetero-geneous.Prior meta-analyses of six or fewer studies that were published 2 years ago were therefore underpowered to yield convincing evidence.AIM To update the efficacy and safety of ECE-LAMS for treatment of biliary ob-struction after ERCP failure.METHODS We searched PubMed,EMBASE,and Scopus databases from the inception of the ECE technique to May 13,2022.Primary outcome measure was pooled technical success rate,and secondary outcomes were pooled rates of clinical success,re-intervention,and adverse events.Meta-analysis was performed using a random-effects model following Freeman-Tukey double-arcsine transformation in R soft-ware(version 4.1.3).RESULTS Fourteen eligible studies involving 620 participants were ultimately included.The pooled rate of technical success was 96.7%,and clinical success was 91.0%.Adverse events were reported in 17.5%of patients.Overall reinter-vention rate was 7.3%.Subgroup analyses showed results were generally consistent.CONCLUSION ECE-LAMS has favorable success with acceptable adverse events in relieving biliary obstruction when ERCP is impossible.The consistency of results across most subgroups suggested that this is a generalizable approach.
基金Supported by the National Natural Science Foundation of China for Young Scholars(No.81802678)the Guangdong Natural Science Foundation Project(No.2018A030310107)+1 种基金the Guangzhou Basic and Applied Basic Research Foundation(No.202102021116,No.202201010307,No.202201010299)the Guangdong Province Administration of Traditional Chinese Medicine Project(No.20231210).