Due to the status of the Dakar region as the former capital of AOF (French West Africa) and current capital of the Republic of Senegal, it is home to a very large part of the population and most of the socio-economic,...Due to the status of the Dakar region as the former capital of AOF (French West Africa) and current capital of the Republic of Senegal, it is home to a very large part of the population and most of the socio-economic, administrative and cultural activities on a very small area of the country (0.28%). This situation makes it a very attractive region and subject to strong land pressure. The objective of this article is to study past and current urban dynamics as well as changes in natural spaces, in order to identify new urban centers. The methodological approach consists in analyzing satellite images to understand the evolution of different forms of spatial occupation in the Dakar region, and to study population movement flows and urban forms in order to reveal new urban centers. The results of the study show that the Dakar urban space is characterized by diverse forms which express a heterogeneous set of spaces. They also revealed the emergence of new clusters between 1986 and 2016, notably Ngor, Grand Yoff, Parcelles Assainies in the North-West, and Keur Massar and the North of the communes of Rufisque in the eastern part of the Dakar region.展开更多
Diembéring, a municipality in Ziguinchor region (with 21 villages) has a considerable deficit in drinking water supply to the population. And yet the sources of supply are not lacking. In this part of the region,...Diembéring, a municipality in Ziguinchor region (with 21 villages) has a considerable deficit in drinking water supply to the population. And yet the sources of supply are not lacking. In this part of the region, the quality water supply rate remains very low. This article follows a process of collection, analysis and exploitation of data (hydrogeological, geomorphological, geological) obtained at the site level. Then, an evaluation of the population compared to the horizon of 2041 is carried out, which allows the estimation of the evolution of the necessary drinking water needs. The geographical and hydraulic criteria allowed us to subdivide the system into two very distinct networks: two multi-village adduction systems (SAEMV1 and SAEMV2) composed of two water towers of 200 m3 each for a HMT = 45 m, serving standpipes [1]. So, for [2]: • SAEMV1 (14 villages): the population is estimated at 10,400 inhabitants in 2041 and water needs are estimated at 365.849 m3/s;• SAEMV2 (07 villages): population is estimated at 38,354 inhabitants in 2041 and drinking water needs are estimated at 1,216.537 m3/s. As designed, this article is in line with the strategy that aims to promote access to drinking water as a means of reducing poverty [3].展开更多
In Senegal, basalt aggregates are the aggregates used for the production of asphalt. They are also in some condition in base layer. However, the only licensed and operated basalt quarry in the west-central part of the...In Senegal, basalt aggregates are the aggregates used for the production of asphalt. They are also in some condition in base layer. However, the only licensed and operated basalt quarry in the west-central part of the country is finished and has reached very important depths thus constituting an environmental threat. This is how quartzite present in the east of the country precisely in the department of Bakel would constitute an alternative to basalt. For this purpose, the performance of two bituminous concretes based on quartzite and basalt was compared. One is made from Diack basalt aggregates, considered as the reference aggregate for asphalt in Senegal and the other is based on Bakel quartzite aggregates, they are both class 0/14. The mechanical performance of two bituminous concretes is evaluated using the Marshall method. The results obtained from the marshall tests give compactness values between 94% and 97% representing the limits laid down in the technical specifications, the creep values for quartzite-based asphalt concrete, while respecting the limit values, are higher than those obtained with basalt aggregates. Thus showing that the former is less resistant to deformation than the former. For both bituminous mixtures, the stability values remain above the minimum value of 1000 kgf set by the specifications. The water resistance test carried out on the two bituminous concretes based on basalt aggregate and quartzite aggregate gives values of immersion/compression ratio (R’c/Rc) equal to 0.72 and 0.82 respectively. These values are above the minimum required value (0.70) in the technical specifications in Senegal.展开更多
This work presents the results of geotechnical tests carried out in the laboratory on specimens of Quaternary olivine basanites from the Cap-Vert peninsula of Dakar. The samples were taken following geotechnical inves...This work presents the results of geotechnical tests carried out in the laboratory on specimens of Quaternary olivine basanites from the Cap-Vert peninsula of Dakar. The samples were taken following geotechnical investigations in the Fann-PE, Mermoz-Ouakam, Yoff and Ngor areas respectively. The results obtained show a dry density between 20.45 and 29.30 kN/m<sup>3</sup> which corresponds to medium to high density basanites. The porosity varies between 0.33% and 4.20%. For microlitic basanites, the porosity remains low, on the other hand, for micrograined basanites;a slight increase in porosity is noticed. As for the methylene blue adsorption test value measured, it is between 0.25 and 1.10. The uniaxial compression strength (Rc) and Young’s modulus (E) vary respectively from 12.19 MPa to 41.748 MPa and from 1477.6 MPa to 7699.1 MPa. The low strength values are recorded in altered and vesicular basanites. Also, a correlation was made between uniaxial compression strength and porosity and showed a gradual decrease in strength with increasing porosity.展开更多
The recovery of plastic waste has a positive impact on two fronts: The environment, through waste reduction, and the economy, through its use in road construction. This work involves recycling plastic variants such as...The recovery of plastic waste has a positive impact on two fronts: The environment, through waste reduction, and the economy, through its use in road construction. This work involves recycling plastic variants such as Polypropylene (PP) 50% and LDPE (Low Density Polyethylene) 50% in proportions of 2% to 8%, incorporated into a 0/14 BBSG. The results of the Marshall test gave stability values ranging from 826 to 1523 kg and creep values from 5.5 to 2.45 mm. The Duriez test gave r/R values ranging from 0.769 to 0.786, with water absorption percentages from 2.24% to 0.69%. The PCG test at 80 gyrations gave void percentages ranging from 11.9% to 5.23%. The rutting test gives a rutting depth percentage that drops at 30,000 cycles from 11.5% to 1.3%. This study shows a considerable increase in the mechanical characteristics of asphalt mixes by adding plastic waste.展开更多
The main purpose of this article is to choose among advanced rheological models used in the French rational design, one that best represents the viscoelastic behavior of asphalt mixtures mixed with aggregates of Seneg...The main purpose of this article is to choose among advanced rheological models used in the French rational design, one that best represents the viscoelastic behavior of asphalt mixtures mixed with aggregates of Senegal. The model chosen will be the basis for the development of computational tools for stress and strain for Senegal. However, the calibration of these models needs complex modulus test results. In opposition to mechanical models the complex modulus can directly characterize the viscoelastic behavior of bituminous materials. Here determination is performed in the laboratory by using several types of tests divided into two groups: homogeneous tests and non-homogeneous tests. The choice of model will be carried out by statistical analysis through the least squares method. To this end, a study was carried out to “Laboratory of Pavement and Bituminous Materials” (LCMB) with asphalt concrete mixed with aggregate from Senegal named basalt of Diack and quartzite of Bakel. In this study, the test used to measure the complex modulus is the Canadian test method LC 26-700 (Determination of the complex modulus by tension-compression). There mainly exist two viewing complex modulus planes for laboratory test results: the Cole and Cole plane and the Black space. The uniqueness of the data points in these two areas means that studied asphalt concretes are thermorheologically simple and that the principle of time-temperature superposition can be applied. This means that the master curve may be drawn and that the same modulus value can be obtained for different pairs (frequency-temperature). These master curves are fitted during the calibration process by the advanced rheological models. One of the most used software in the French rational design for the visualization of complex modulus test results and calibration of rheological models developed tools is named Visco-analysis. In this study, its use in interpreting the complex modulus test results and calibration models shows that, the studied asphalt concretes are thermorheologically simple, because they present good uniqueness of their Black and Cole and Cole and Black diagrams. They allow a good application of the principle of time temperature superposition. The statistical analysis of calibration models by the least squares method has shown that the three studied models are suitable for modeling the linear viscoelastic behavior of asphalt mixtures formulated with the basalt of Diack and the quartzite of Bakel. Indeed their calibration has very similar precision values of “Sum of Squared Deviation” (SSD) about 0.185. However, the lower precision value (0.169) is obtained with the 2S2P1D model.展开更多
The Senegalese road network is strongly influenced in the long term by seasonal variations in climate and weather conditions. Indeed, much of the damage is due to these environmental factors. The objective of th... The Senegalese road network is strongly influenced in the long term by seasonal variations in climate and weather conditions. Indeed, much of the damage is due to these environmental factors. The objective of this paper is to study the behaviour of bituminous structures under the effect of high temperatures. Material samples were taken for a physico-mechanical characterization of the coated components. The results show that Marshall creep (2.87, 3.39, 5, 5.5 mm) and the bitumen penetrability increase with the increasing of temperatures respectively from 34°C to 45<span style="white-space:normal;">°</span>C and from 20<span style="white-space:normal;">°</span>C to 50<span style="white-space:normal;">°</span>C. Marshall Stability drops from 15.81 kN to 11.31 kN for temperatures between 34<span style="white-space:normal;">°</span>C and 45<span style="white-space:normal;">°</span>C. The simulation carried out on Alize-LCPC shows an increase in distortions of traction at the basis of the rolling layer and at the top of the platform if temperatures vary between 34<span style="white-space:normal;">°</span>C and 45<span style="white-space:normal;">°</span>C. This work makes it possible to conform that the bituminous concrete is thermally sensitive and the hypothesis of fixing the constant modulus of the bituminous layers in Senegal for all projects remains unsuitable for a good dimensioning of sustainable road structures. The knowledge of the equivalent regional temperature will make it possible to produce quality pavements with a long lifespan.展开更多
In Senegal, rock mechanic studies began in last four years and were a very new engineering domain. So, the first stage is to characterize geological materials. It is on this way that this work is done. This paper anal...In Senegal, rock mechanic studies began in last four years and were a very new engineering domain. So, the first stage is to characterize geological materials. It is on this way that this work is done. This paper analyzes geomechanical parameters of sandstones of Dindifélo and basalt of Bafoundou belonging to the Proterozoic rocks domain of eastern Senegal. By Rock Mass Rating (RMR) and Geological Strength Index (GSI), sandstones of the Dindifello Cliff show fair to poor characteristics while basalts of the hills of Bafoundou are fair quality. In addition to the qualities of rock mass, Young moduli, uniaxial compressive strengths and tensile strength of rock mass are also defined using Rock Quality Designation (RQD) GSI, RMR. Hoek-Brown parameters m and a, depend both on the fracturation and the content fine in the rock. Values of mechanical parameters are different when deduced from RMR, GSI and from intact rock laboratory test. Those differences are due to variables taken account. The variation depends also on the quality of the rock. Statistical analysis shows possible unstabilities which depend on rock mass parameters but with acceptable probability of failure. Probability of failure is the highest when deducing from Mohr criterion than from Hoek-Brown criterion.展开更多
文摘Due to the status of the Dakar region as the former capital of AOF (French West Africa) and current capital of the Republic of Senegal, it is home to a very large part of the population and most of the socio-economic, administrative and cultural activities on a very small area of the country (0.28%). This situation makes it a very attractive region and subject to strong land pressure. The objective of this article is to study past and current urban dynamics as well as changes in natural spaces, in order to identify new urban centers. The methodological approach consists in analyzing satellite images to understand the evolution of different forms of spatial occupation in the Dakar region, and to study population movement flows and urban forms in order to reveal new urban centers. The results of the study show that the Dakar urban space is characterized by diverse forms which express a heterogeneous set of spaces. They also revealed the emergence of new clusters between 1986 and 2016, notably Ngor, Grand Yoff, Parcelles Assainies in the North-West, and Keur Massar and the North of the communes of Rufisque in the eastern part of the Dakar region.
文摘Diembéring, a municipality in Ziguinchor region (with 21 villages) has a considerable deficit in drinking water supply to the population. And yet the sources of supply are not lacking. In this part of the region, the quality water supply rate remains very low. This article follows a process of collection, analysis and exploitation of data (hydrogeological, geomorphological, geological) obtained at the site level. Then, an evaluation of the population compared to the horizon of 2041 is carried out, which allows the estimation of the evolution of the necessary drinking water needs. The geographical and hydraulic criteria allowed us to subdivide the system into two very distinct networks: two multi-village adduction systems (SAEMV1 and SAEMV2) composed of two water towers of 200 m3 each for a HMT = 45 m, serving standpipes [1]. So, for [2]: • SAEMV1 (14 villages): the population is estimated at 10,400 inhabitants in 2041 and water needs are estimated at 365.849 m3/s;• SAEMV2 (07 villages): population is estimated at 38,354 inhabitants in 2041 and drinking water needs are estimated at 1,216.537 m3/s. As designed, this article is in line with the strategy that aims to promote access to drinking water as a means of reducing poverty [3].
文摘In Senegal, basalt aggregates are the aggregates used for the production of asphalt. They are also in some condition in base layer. However, the only licensed and operated basalt quarry in the west-central part of the country is finished and has reached very important depths thus constituting an environmental threat. This is how quartzite present in the east of the country precisely in the department of Bakel would constitute an alternative to basalt. For this purpose, the performance of two bituminous concretes based on quartzite and basalt was compared. One is made from Diack basalt aggregates, considered as the reference aggregate for asphalt in Senegal and the other is based on Bakel quartzite aggregates, they are both class 0/14. The mechanical performance of two bituminous concretes is evaluated using the Marshall method. The results obtained from the marshall tests give compactness values between 94% and 97% representing the limits laid down in the technical specifications, the creep values for quartzite-based asphalt concrete, while respecting the limit values, are higher than those obtained with basalt aggregates. Thus showing that the former is less resistant to deformation than the former. For both bituminous mixtures, the stability values remain above the minimum value of 1000 kgf set by the specifications. The water resistance test carried out on the two bituminous concretes based on basalt aggregate and quartzite aggregate gives values of immersion/compression ratio (R’c/Rc) equal to 0.72 and 0.82 respectively. These values are above the minimum required value (0.70) in the technical specifications in Senegal.
文摘This work presents the results of geotechnical tests carried out in the laboratory on specimens of Quaternary olivine basanites from the Cap-Vert peninsula of Dakar. The samples were taken following geotechnical investigations in the Fann-PE, Mermoz-Ouakam, Yoff and Ngor areas respectively. The results obtained show a dry density between 20.45 and 29.30 kN/m<sup>3</sup> which corresponds to medium to high density basanites. The porosity varies between 0.33% and 4.20%. For microlitic basanites, the porosity remains low, on the other hand, for micrograined basanites;a slight increase in porosity is noticed. As for the methylene blue adsorption test value measured, it is between 0.25 and 1.10. The uniaxial compression strength (Rc) and Young’s modulus (E) vary respectively from 12.19 MPa to 41.748 MPa and from 1477.6 MPa to 7699.1 MPa. The low strength values are recorded in altered and vesicular basanites. Also, a correlation was made between uniaxial compression strength and porosity and showed a gradual decrease in strength with increasing porosity.
文摘The recovery of plastic waste has a positive impact on two fronts: The environment, through waste reduction, and the economy, through its use in road construction. This work involves recycling plastic variants such as Polypropylene (PP) 50% and LDPE (Low Density Polyethylene) 50% in proportions of 2% to 8%, incorporated into a 0/14 BBSG. The results of the Marshall test gave stability values ranging from 826 to 1523 kg and creep values from 5.5 to 2.45 mm. The Duriez test gave r/R values ranging from 0.769 to 0.786, with water absorption percentages from 2.24% to 0.69%. The PCG test at 80 gyrations gave void percentages ranging from 11.9% to 5.23%. The rutting test gives a rutting depth percentage that drops at 30,000 cycles from 11.5% to 1.3%. This study shows a considerable increase in the mechanical characteristics of asphalt mixes by adding plastic waste.
文摘The main purpose of this article is to choose among advanced rheological models used in the French rational design, one that best represents the viscoelastic behavior of asphalt mixtures mixed with aggregates of Senegal. The model chosen will be the basis for the development of computational tools for stress and strain for Senegal. However, the calibration of these models needs complex modulus test results. In opposition to mechanical models the complex modulus can directly characterize the viscoelastic behavior of bituminous materials. Here determination is performed in the laboratory by using several types of tests divided into two groups: homogeneous tests and non-homogeneous tests. The choice of model will be carried out by statistical analysis through the least squares method. To this end, a study was carried out to “Laboratory of Pavement and Bituminous Materials” (LCMB) with asphalt concrete mixed with aggregate from Senegal named basalt of Diack and quartzite of Bakel. In this study, the test used to measure the complex modulus is the Canadian test method LC 26-700 (Determination of the complex modulus by tension-compression). There mainly exist two viewing complex modulus planes for laboratory test results: the Cole and Cole plane and the Black space. The uniqueness of the data points in these two areas means that studied asphalt concretes are thermorheologically simple and that the principle of time-temperature superposition can be applied. This means that the master curve may be drawn and that the same modulus value can be obtained for different pairs (frequency-temperature). These master curves are fitted during the calibration process by the advanced rheological models. One of the most used software in the French rational design for the visualization of complex modulus test results and calibration of rheological models developed tools is named Visco-analysis. In this study, its use in interpreting the complex modulus test results and calibration models shows that, the studied asphalt concretes are thermorheologically simple, because they present good uniqueness of their Black and Cole and Cole and Black diagrams. They allow a good application of the principle of time temperature superposition. The statistical analysis of calibration models by the least squares method has shown that the three studied models are suitable for modeling the linear viscoelastic behavior of asphalt mixtures formulated with the basalt of Diack and the quartzite of Bakel. Indeed their calibration has very similar precision values of “Sum of Squared Deviation” (SSD) about 0.185. However, the lower precision value (0.169) is obtained with the 2S2P1D model.
文摘 The Senegalese road network is strongly influenced in the long term by seasonal variations in climate and weather conditions. Indeed, much of the damage is due to these environmental factors. The objective of this paper is to study the behaviour of bituminous structures under the effect of high temperatures. Material samples were taken for a physico-mechanical characterization of the coated components. The results show that Marshall creep (2.87, 3.39, 5, 5.5 mm) and the bitumen penetrability increase with the increasing of temperatures respectively from 34°C to 45<span style="white-space:normal;">°</span>C and from 20<span style="white-space:normal;">°</span>C to 50<span style="white-space:normal;">°</span>C. Marshall Stability drops from 15.81 kN to 11.31 kN for temperatures between 34<span style="white-space:normal;">°</span>C and 45<span style="white-space:normal;">°</span>C. The simulation carried out on Alize-LCPC shows an increase in distortions of traction at the basis of the rolling layer and at the top of the platform if temperatures vary between 34<span style="white-space:normal;">°</span>C and 45<span style="white-space:normal;">°</span>C. This work makes it possible to conform that the bituminous concrete is thermally sensitive and the hypothesis of fixing the constant modulus of the bituminous layers in Senegal for all projects remains unsuitable for a good dimensioning of sustainable road structures. The knowledge of the equivalent regional temperature will make it possible to produce quality pavements with a long lifespan.
文摘In Senegal, rock mechanic studies began in last four years and were a very new engineering domain. So, the first stage is to characterize geological materials. It is on this way that this work is done. This paper analyzes geomechanical parameters of sandstones of Dindifélo and basalt of Bafoundou belonging to the Proterozoic rocks domain of eastern Senegal. By Rock Mass Rating (RMR) and Geological Strength Index (GSI), sandstones of the Dindifello Cliff show fair to poor characteristics while basalts of the hills of Bafoundou are fair quality. In addition to the qualities of rock mass, Young moduli, uniaxial compressive strengths and tensile strength of rock mass are also defined using Rock Quality Designation (RQD) GSI, RMR. Hoek-Brown parameters m and a, depend both on the fracturation and the content fine in the rock. Values of mechanical parameters are different when deduced from RMR, GSI and from intact rock laboratory test. Those differences are due to variables taken account. The variation depends also on the quality of the rock. Statistical analysis shows possible unstabilities which depend on rock mass parameters but with acceptable probability of failure. Probability of failure is the highest when deducing from Mohr criterion than from Hoek-Brown criterion.