This study evaluated the value of high-frequency ultrasonograpy for early detection of dorsal artery of foot in patients with type 2 diabetes mellitus (MD). Eighty subjects including 40 patients with type 2 MD (T2D...This study evaluated the value of high-frequency ultrasonograpy for early detection of dorsal artery of foot in patients with type 2 diabetes mellitus (MD). Eighty subjects including 40 patients with type 2 MD (T2DM group) and 40 healthy volunteers (NC group) were recruited. The intima-media thickness (IMT), the inner diameter and the perfusion of dorsal artery of foot were measured by using high-frequency ultrasonograpy. Meanwhile, the parameters of vascular elasticity, including stiffness parameter (]3), pressure-strain elastic modulus (Ep), arterial compliance (AC), augment index (AI), and pulse wave conducting velocity (PWV]3) were detected by means of echo-tracking technique. The results showed that no significant difference was found in the IMT, systolic diameter (Ds), diastolic diameter (Dd) and peak systolic velocity (PSV) between T2DM and NC groups. Ep and PWVβ were increased, and AC was decreased in T2DM group as compared with those in NC group with the differences being significant (P〈0.05 for all). There was no significant difference in β and AI between T2DM and NC groups. It was concluded that high-frequency ultra- sonography in combination with echo-tracking technique is sensitive and non-invasive, and can be used for early detection of sclerosis of the lower extremity artery in patients with type 2 MD.展开更多
Summary: This study aimed to examine the optimal conditions of laser-induced interstitial ther- motherapy (LITT) via a single-needle delivery system, and the ablation-related pathological and ultra- sonic changes. ...Summary: This study aimed to examine the optimal conditions of laser-induced interstitial ther- motherapy (LITT) via a single-needle delivery system, and the ablation-related pathological and ultra- sonic changes. Ultrasound (US)-guided LITT (EchoLaser system) was performed at the output power of 2--4 Wattage (W) for 1-10 min in ex vivo bovine liver. Based on the results of the ex vivo study, the output power of 3 and 4 W with different durations was applied to in vivo rabbit livers (n=24), and VX2 tumors implanted in the hind limbs of rabbits (n=24). The ablation area was histologically determined by hematoxylin-eosin (HE) staining. Traditional US and contrast enhanced ultrasound (CEUS) were used to evaluate the treatment outcomes. The results showed: (1) In the bovine liver, ablation disruption was grossly seen, including a strip-like ablation crater, a carbonization zone anteriorly along the fiber tip, and a surrounding gray-white coagulation zone. The coagulation area, 1.2 cm in length and 1.0 cm in width, was formed in the bovine liver subjected to the ablation at 3 W for 5 min and 4 W for 4 rain, and it extended slightly with the ablation time. (2) In the rabbit liver, after LITT at 3 W for 3 min and more, the coagulation area with length greater than or equal to 1.2 cm, and width greater than or equal to 1.0 cm, was found. Similar coagulation area was seen in the implanted VX2 carcinoma at 3 W for 5 min. (3) Gross examination of the liver and carcinoma showed three distinct regions: ablation cra- ter/carbonization, coagulation and congestion distributed from the center outwards. (4) Microscopy re- vealed four zones after LITT, including ablation crater/carbonization, coagulation, edema and conges- tion from the center outwards. A large area with coagulative necrosis was observed around a vessel in the peripheral area with edema and hyperemia. (5) The size of coagulation was consistent well to the CEUS findings. It was concluded that EchoLaser system at low power can produce a coagulation area larger than 1.0 cm×1.0 cm during a short time period. The real-time US imaging can be used to effec- tively guide and assess the treatment.展开更多
This study examined the wave intensity (WI) of the carotid artery in patients with hyperthyroid in order to assess the hemodynamic changes of hyperthyroid patients.A total of 86 hyperthyroid patients without cardiac m...This study examined the wave intensity (WI) of the carotid artery in patients with hyperthyroid in order to assess the hemodynamic changes of hyperthyroid patients.A total of 86 hyperthyroid patients without cardiac morphological changes and arrhythmia, and 80 healthy control subjects were enrolled in the study.Right common carotid artery (RCCA) was selected for ultrasonic imaging to obtain WI indices, including amplitude of the peak during early systole (W1), amplitude of the peak during late systole (W2), area of the negative wave during mid-systole (NA), interval between R wave of electrocardiogram and W1 (R-1st), interval between W1 and W2 (1st-2nd).The levels of serum thyroid hormones, consisting of free triiodothyronine (FT3), free thyroxin (FT4) and thyroid stimulating hormone (TSH), were measured in hyperthyroid patients.Echocardiographic indices including left ventricular ejection fraction (LVEF) and left ventricular fraction shortening (LVFS) were determined in each subject.The results showed that the W1, W2, NA, and (1st-2nd×HR) in hyperthyroid patients were significantly higher than those in healthy controls.There was no significant difference in LVEF and LVFS between the two groups.FT3 was correlated with W1, W2, NA, (1st-2nd×HR), pulse pressure (PP) and heart rate (HR) in hyperthyroid patients.Several abnormal waves on WI curves were present in 19 hyperthyroid patients during mid-systole.It was concluded that WI technique may prove a real-time, noninvasive, sensitive and convenient tool for assessing the cardiac function and hemodynamic alterations in hyperthyroid patients.展开更多
文摘This study evaluated the value of high-frequency ultrasonograpy for early detection of dorsal artery of foot in patients with type 2 diabetes mellitus (MD). Eighty subjects including 40 patients with type 2 MD (T2DM group) and 40 healthy volunteers (NC group) were recruited. The intima-media thickness (IMT), the inner diameter and the perfusion of dorsal artery of foot were measured by using high-frequency ultrasonograpy. Meanwhile, the parameters of vascular elasticity, including stiffness parameter (]3), pressure-strain elastic modulus (Ep), arterial compliance (AC), augment index (AI), and pulse wave conducting velocity (PWV]3) were detected by means of echo-tracking technique. The results showed that no significant difference was found in the IMT, systolic diameter (Ds), diastolic diameter (Dd) and peak systolic velocity (PSV) between T2DM and NC groups. Ep and PWVβ were increased, and AC was decreased in T2DM group as compared with those in NC group with the differences being significant (P〈0.05 for all). There was no significant difference in β and AI between T2DM and NC groups. It was concluded that high-frequency ultra- sonography in combination with echo-tracking technique is sensitive and non-invasive, and can be used for early detection of sclerosis of the lower extremity artery in patients with type 2 MD.
基金supported by grants from the National Natural Science Foundation of China(No.81000616)the Natural Science Foundation of Hubei Province,China(No.2009cdb264 and No.2012ffb02526)
文摘Summary: This study aimed to examine the optimal conditions of laser-induced interstitial ther- motherapy (LITT) via a single-needle delivery system, and the ablation-related pathological and ultra- sonic changes. Ultrasound (US)-guided LITT (EchoLaser system) was performed at the output power of 2--4 Wattage (W) for 1-10 min in ex vivo bovine liver. Based on the results of the ex vivo study, the output power of 3 and 4 W with different durations was applied to in vivo rabbit livers (n=24), and VX2 tumors implanted in the hind limbs of rabbits (n=24). The ablation area was histologically determined by hematoxylin-eosin (HE) staining. Traditional US and contrast enhanced ultrasound (CEUS) were used to evaluate the treatment outcomes. The results showed: (1) In the bovine liver, ablation disruption was grossly seen, including a strip-like ablation crater, a carbonization zone anteriorly along the fiber tip, and a surrounding gray-white coagulation zone. The coagulation area, 1.2 cm in length and 1.0 cm in width, was formed in the bovine liver subjected to the ablation at 3 W for 5 min and 4 W for 4 rain, and it extended slightly with the ablation time. (2) In the rabbit liver, after LITT at 3 W for 3 min and more, the coagulation area with length greater than or equal to 1.2 cm, and width greater than or equal to 1.0 cm, was found. Similar coagulation area was seen in the implanted VX2 carcinoma at 3 W for 5 min. (3) Gross examination of the liver and carcinoma showed three distinct regions: ablation cra- ter/carbonization, coagulation and congestion distributed from the center outwards. (4) Microscopy re- vealed four zones after LITT, including ablation crater/carbonization, coagulation, edema and conges- tion from the center outwards. A large area with coagulative necrosis was observed around a vessel in the peripheral area with edema and hyperemia. (5) The size of coagulation was consistent well to the CEUS findings. It was concluded that EchoLaser system at low power can produce a coagulation area larger than 1.0 cm×1.0 cm during a short time period. The real-time US imaging can be used to effec- tively guide and assess the treatment.
文摘This study examined the wave intensity (WI) of the carotid artery in patients with hyperthyroid in order to assess the hemodynamic changes of hyperthyroid patients.A total of 86 hyperthyroid patients without cardiac morphological changes and arrhythmia, and 80 healthy control subjects were enrolled in the study.Right common carotid artery (RCCA) was selected for ultrasonic imaging to obtain WI indices, including amplitude of the peak during early systole (W1), amplitude of the peak during late systole (W2), area of the negative wave during mid-systole (NA), interval between R wave of electrocardiogram and W1 (R-1st), interval between W1 and W2 (1st-2nd).The levels of serum thyroid hormones, consisting of free triiodothyronine (FT3), free thyroxin (FT4) and thyroid stimulating hormone (TSH), were measured in hyperthyroid patients.Echocardiographic indices including left ventricular ejection fraction (LVEF) and left ventricular fraction shortening (LVFS) were determined in each subject.The results showed that the W1, W2, NA, and (1st-2nd×HR) in hyperthyroid patients were significantly higher than those in healthy controls.There was no significant difference in LVEF and LVFS between the two groups.FT3 was correlated with W1, W2, NA, (1st-2nd×HR), pulse pressure (PP) and heart rate (HR) in hyperthyroid patients.Several abnormal waves on WI curves were present in 19 hyperthyroid patients during mid-systole.It was concluded that WI technique may prove a real-time, noninvasive, sensitive and convenient tool for assessing the cardiac function and hemodynamic alterations in hyperthyroid patients.