The underwater electrical explosion of an aluminum wire is influenced by many factors, such as wire parameters, pulsed power energy, etc. In this paper, underwater electrical explosion of an aluminum wire was investig...The underwater electrical explosion of an aluminum wire is influenced by many factors, such as wire parameters, pulsed power energy, etc. In this paper, underwater electrical explosion of an aluminum wire was investigated with pulsed voltage in the time scale of a few microseconds. A self-integrated Rogowski coil and a voltage divider were used for the measurements of current and voltage at the wire load, respectively. The deposited energy before breakdown was calculated based on experimental waveforms of current and voltage by mathematical method. Effects of the applied voltage, circuit inductance and sion and energy deposition were analyzed by means parameters of Al wire on the electrical exploof experiments and calculation. The results show that the current rise rate has an important influence on explosion process, such as the energy deposition before breakdown, the electrical power as well as the various explosion stages. A higher current rise rate can be achieved by increasing applied voltage and decreasing circuit inductance. The inhomogeneity of the energy deposition will result in prematured breakdown as well as lowered energy deposition, making the explosion process of wire more complicated.展开更多
为了提高移动互联网环境下变电带电检测移动作业的安全性和效率,提出基于移动互联网的变电带电检测运维系统。依据变电带电检测移动作业平台进行变电带电检测运维系统的模块化开发设计,构建移动互联网环境下变电带电检测运维系统的移动...为了提高移动互联网环境下变电带电检测移动作业的安全性和效率,提出基于移动互联网的变电带电检测运维系统。依据变电带电检测移动作业平台进行变电带电检测运维系统的模块化开发设计,构建移动互联网环境下变电带电检测运维系统的移动作业平台,统计不同检测负责人在一定时间范围内检测变电站任务数,通过移动互联网利用App与现场检测人员实现远程控制。在移动互联网环境下,采用交叉编译模块进行变电带点检测视觉系统的模块化设计,建立变电带电检测运维系统的资源库和数据库,在不同的硬件平台上,实现变电带电检测和运维管理,在Linux或Windows Server 2008平台上实现系统的软件设计。测试结果表明,设计的变电带电检测运维系统输出稳定性较好,可靠性较强。展开更多
基金supported by the State Key Program of National Natural Science Foundation of China(No.50637010)
文摘The underwater electrical explosion of an aluminum wire is influenced by many factors, such as wire parameters, pulsed power energy, etc. In this paper, underwater electrical explosion of an aluminum wire was investigated with pulsed voltage in the time scale of a few microseconds. A self-integrated Rogowski coil and a voltage divider were used for the measurements of current and voltage at the wire load, respectively. The deposited energy before breakdown was calculated based on experimental waveforms of current and voltage by mathematical method. Effects of the applied voltage, circuit inductance and sion and energy deposition were analyzed by means parameters of Al wire on the electrical exploof experiments and calculation. The results show that the current rise rate has an important influence on explosion process, such as the energy deposition before breakdown, the electrical power as well as the various explosion stages. A higher current rise rate can be achieved by increasing applied voltage and decreasing circuit inductance. The inhomogeneity of the energy deposition will result in prematured breakdown as well as lowered energy deposition, making the explosion process of wire more complicated.
文摘为了提高移动互联网环境下变电带电检测移动作业的安全性和效率,提出基于移动互联网的变电带电检测运维系统。依据变电带电检测移动作业平台进行变电带电检测运维系统的模块化开发设计,构建移动互联网环境下变电带电检测运维系统的移动作业平台,统计不同检测负责人在一定时间范围内检测变电站任务数,通过移动互联网利用App与现场检测人员实现远程控制。在移动互联网环境下,采用交叉编译模块进行变电带点检测视觉系统的模块化设计,建立变电带电检测运维系统的资源库和数据库,在不同的硬件平台上,实现变电带电检测和运维管理,在Linux或Windows Server 2008平台上实现系统的软件设计。测试结果表明,设计的变电带电检测运维系统输出稳定性较好,可靠性较强。