A preparation technology of chloride contaminated resistant concrete was presented. The newly developed non-steady-state migration test method was employed for the evaluation of chloride ions diffusion coefficient of ...A preparation technology of chloride contaminated resistant concrete was presented. The newly developed non-steady-state migration test method was employed for the evaluation of chloride ions diffusion coefficient of the concrete. The experimental results show that this method has a good correlation with the traditional NT Build 443 method, and it provides an effective and quick approach to assess the resistant capacity of concrete against chloride ions.展开更多
文摘A preparation technology of chloride contaminated resistant concrete was presented. The newly developed non-steady-state migration test method was employed for the evaluation of chloride ions diffusion coefficient of the concrete. The experimental results show that this method has a good correlation with the traditional NT Build 443 method, and it provides an effective and quick approach to assess the resistant capacity of concrete against chloride ions.