We propose a method to directly measure phase-related noise characteristics of single-frequency lasers in the 728–980 nm band based on a 120°phase difference interferometer.Differential phase information of the ...We propose a method to directly measure phase-related noise characteristics of single-frequency lasers in the 728–980 nm band based on a 120°phase difference interferometer.Differential phase information of the laser under test is demodulated via the interferometer.Other parameters related to the phase noise characteristics such as linewidth at different observation time, phase/frequency noise, power spectrum density of phase/frequency fluctuation, and Allan deviation are further obtained.Frequency noise as low as 1 Hz^2/Hz can be measured using our system.Then the phase-related noise characteristics of two commercial lasers frequently used in cold atomic clocks are studied systematically by the method.Furthermore, several influencing factors and their relative evolution laws are also revealed, such as the pump current and frequency-locking control parameters.This would help to optimize the laser performance, select laser sources, and evaluate the system performance for cold atomic physics applications.展开更多
Based on dense wavelength-division multiplexing technology, frequency transfer and time synchronization are simultaneously realized over a compensated cascaded fiber link of 430 km, which is a part of the Beijing- Sha...Based on dense wavelength-division multiplexing technology, frequency transfer and time synchronization are simultaneously realized over a compensated cascaded fiber link of 430 km, which is a part of the Beijing- Shanghai optical fiber backbone network. The entire cascaded system consists of two stages with fiber links of 280 and 150 km, respectively. To keep high symmetry and low noise, specific bi-directional erbium-doped fiber amplifiers are used to compensate the large optical attenuation of each fiber link. When the compensation servo is active in every stage, the cascaded system achieves the stability of 1.94 × 10-13 at I s and 1.34 × 10-16 at 104 s, for frequency transfer. It is also verified that the actual results of the cascaded system are in good agreement with the theoretical ones calculated from error theory. Simultaneously, after calibration of each stage, time synchronization is also realized. The final accuracy of the whole system is within 94 ps.展开更多
基金Project supported by the National Natural Science Foundation of China(Grant Nos.61875214,61535014,and 61775225)Scientific Innovation Fund of Chinese Academy of Sciences(Grant No.CXJJ-17S010)
文摘We propose a method to directly measure phase-related noise characteristics of single-frequency lasers in the 728–980 nm band based on a 120°phase difference interferometer.Differential phase information of the laser under test is demodulated via the interferometer.Other parameters related to the phase noise characteristics such as linewidth at different observation time, phase/frequency noise, power spectrum density of phase/frequency fluctuation, and Allan deviation are further obtained.Frequency noise as low as 1 Hz^2/Hz can be measured using our system.Then the phase-related noise characteristics of two commercial lasers frequently used in cold atomic clocks are studied systematically by the method.Furthermore, several influencing factors and their relative evolution laws are also revealed, such as the pump current and frequency-locking control parameters.This would help to optimize the laser performance, select laser sources, and evaluate the system performance for cold atomic physics applications.
基金supported in part by the National High-Tech R&D Program(863 Program)under Grant No.2013AA122901
文摘Based on dense wavelength-division multiplexing technology, frequency transfer and time synchronization are simultaneously realized over a compensated cascaded fiber link of 430 km, which is a part of the Beijing- Shanghai optical fiber backbone network. The entire cascaded system consists of two stages with fiber links of 280 and 150 km, respectively. To keep high symmetry and low noise, specific bi-directional erbium-doped fiber amplifiers are used to compensate the large optical attenuation of each fiber link. When the compensation servo is active in every stage, the cascaded system achieves the stability of 1.94 × 10-13 at I s and 1.34 × 10-16 at 104 s, for frequency transfer. It is also verified that the actual results of the cascaded system are in good agreement with the theoretical ones calculated from error theory. Simultaneously, after calibration of each stage, time synchronization is also realized. The final accuracy of the whole system is within 94 ps.