期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Fast Data Processing of a Polarimeter-Interferometer System on J-TEXT
1
作者 刘煜锴 高丽 +3 位作者 刘海庆 杨曜 高翔 J-TEXT Team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第12期1143-1147,共5页
A method of fast data processing has been developed to rapidly obtain evolution of the electron density profile for a multichannel polarimeter-interferometer system(POLARIS)on J-TEXT. Compared with the Abel inversio... A method of fast data processing has been developed to rapidly obtain evolution of the electron density profile for a multichannel polarimeter-interferometer system(POLARIS)on J-TEXT. Compared with the Abel inversion method, evolution of the density profile analyzed by this method can quickly offer important information. This method has the advantage of fast calculation speed with the order of ten milliseconds per normal shot and it is capable of processing up to 1 MHz sampled data, which is helpful for studying density sawtooth instability and the disruption between shots. In the duration of a flat-top plasma current of usual ohmic discharges on J-TEXT, shape factor u is ranged from 4 to 5. When the disruption of discharge happens, the density profile becomes peaked and the shape factor u typically decreases to 1. 展开更多
关键词 fast data processing polarimeter-interferometer J-TEXT
下载PDF
基于EAST装置量热系统的第一壁热负荷实验研究
2
作者 庄清 明廷凤 +10 位作者 余耀伟 刘煜锴 周凡 龙飞飞 杨雷 李沂隆 王嵎民 刘少承 刘海庆 李国强 高翔 《核聚变与等离子体物理》 CAS CSCD 北大核心 2020年第3期222-226,共5页
通过测量EAST装置水冷系统的出入口冷却水的温差和流量,搭建了第一壁热负荷测量系统,实现了第一壁热负荷的分布测量。实验结果表明,在上单零偏滤器位形放电实验中,该系统测量的热负荷约占总注入能量的80%,其中,接近50%的热负荷沉积在上... 通过测量EAST装置水冷系统的出入口冷却水的温差和流量,搭建了第一壁热负荷测量系统,实现了第一壁热负荷的分布测量。实验结果表明,在上单零偏滤器位形放电实验中,该系统测量的热负荷约占总注入能量的80%,其中,接近50%的热负荷沉积在上偏滤器区域。高的加热功率会使得第一壁热负荷更快上升。通过冷却水降温曲线拟合计算得出EAST装置上钨偏滤器水冷系统的热衰减时间约为下石墨偏滤器水冷系统的十分之一。 展开更多
关键词 热负荷 热负荷测量系统 长脉冲 水冷系统 EAST
下载PDF
Feasibility of applying the lower cut-off frequency for the density radial coverage extension in EAST reflectometry measurement
3
作者 Jia HUANG Xiang HAN +13 位作者 Kaixuan YE Tao ZHANG Fei WEN Mingfu WU Kangning GENG Gongshun LI Fubin ZHONG Yukai LIU Haoming XIANG Shuqi YANG Shoubiao ZHANG Xiang GAO Ge ZHUANG the EAST Team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第5期112-117,共6页
The extraordinary mode(X-mode)lower cut-off frequency is proposed for use in the reflectometry diagnostic on ITER for the electron density profile measurement,which is a trade-off between extreme plasma parameters and... The extraordinary mode(X-mode)lower cut-off frequency is proposed for use in the reflectometry diagnostic on ITER for the electron density profile measurement,which is a trade-off between extreme plasma parameters and the accessible probing frequency.In contemporary experiments,the lower cutoff frequency can be identified at the probing frequency below the electron cyclotron frequency(f_(ce)) under certain plasma conditions.We provide here,for the first time,the experimental validation of the use of the lower cut-off frequency for the density profiles via the reflectometry measurement on EAST.The corresponding group delay of the lower cut-off frequency evolves continuously with the upper one,revealing a reasonable radial coverage extension of reflectometry measurement toward the plasma core.It is concluded that the lower cut-off frequency can be used as a supplement to the upper one in the density profile inversion process,which is of particular interest in the high magnetic field and/or density discharge to extend the radial coverage of reflectometry measurement. 展开更多
关键词 X-mode reflectometry density profile EAST lower cut-off frequency
下载PDF
Bench Test of the Vibration Compensation Interferometer for EAST Tokamak
4
作者 李恭顺 杨曜 +10 位作者 刘海庆 揭银先 邹志勇 王正兴 曾龙 魏学朝 李维明 兰婷 朱翔 刘煜锴 高翔 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第2期206-210,共5页
A visible laser-based vibration compensation interferometer has recently been designed for the EAST tokamak and the bench test has been finished.The system was optimized for its installation on EAST.The value of the f... A visible laser-based vibration compensation interferometer has recently been designed for the EAST tokamak and the bench test has been finished.The system was optimized for its installation on EAST.The value of the final optical power before the detectors without plasma has been calculated from the component bench test result,which is quite close to the measured value.A nanometer level displacement(of the order of the laser's wavelength) has been clearly measured by a modulation of piezoelectric ceramic unit,proving the system's capability. 展开更多
关键词 vibration compensation system design tokamak diagnostic
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部