To reduce the discharge of the standard bulk Micromegas and GEM detectors, a GEM-Micromegas detector was developed at the Institute of High Energy Physics. Taking into account the advantages of the two detectors, one ...To reduce the discharge of the standard bulk Micromegas and GEM detectors, a GEM-Micromegas detector was developed at the Institute of High Energy Physics. Taking into account the advantages of the two detectors, one GEM foil was set as a preamplifier on the mesh of Micromegas in the structure and the CEM pream- plification decreased the working voltage of Micromegas to significantly reduce the effect of the discharge. At the same gain, the spark probability of the GEM-Micromegas detector can be reduced to a factor 0.01 compared to the standard Micromegas detector, and an even higher gain could be obtained. This paper describes the performance of the X-ray beam detector that was studied at 1W2B Laboratory of Beijing Synchrotron Radiation Facility. Finally, the result of the energy resolution under various X-ray energies was given in different working gases. This indicates that the GEM-Micromegas detector has an energy response capability in an energy range from 6 keV to 20 keV and it could work better than the standard bulk-Micromegas.展开更多
A new concept for a hybrid structure gaseous detector module with ion backflow suppression for the time projection chamber in a future circular collider is presented.It is a hybrid structure cascaded Gas Electron Mult...A new concept for a hybrid structure gaseous detector module with ion backflow suppression for the time projection chamber in a future circular collider is presented.It is a hybrid structure cascaded Gas Electron Multiplier(GEM) with a Micromegas detector.Both Micromegas and GEM have the capability to naturally reduce most of the ions produced in the amplification region.The GEM also acts as the preamplifer device and increases gas gain together with the Micromegas.Feasibility tests of the hybrid detector are performed using an ^(55)Fe X-ray source.The energy resolution is better than 27% for 5.9 keV X-rays.It is demonstrated that a backflow ratio better than 0.2% can be reached in the hybrid readout structure at a gain of 5000.展开更多
基金Supported by National Natural Science Foundation of China(11275224)
文摘To reduce the discharge of the standard bulk Micromegas and GEM detectors, a GEM-Micromegas detector was developed at the Institute of High Energy Physics. Taking into account the advantages of the two detectors, one GEM foil was set as a preamplifier on the mesh of Micromegas in the structure and the CEM pream- plification decreased the working voltage of Micromegas to significantly reduce the effect of the discharge. At the same gain, the spark probability of the GEM-Micromegas detector can be reduced to a factor 0.01 compared to the standard Micromegas detector, and an even higher gain could be obtained. This paper describes the performance of the X-ray beam detector that was studied at 1W2B Laboratory of Beijing Synchrotron Radiation Facility. Finally, the result of the energy resolution under various X-ray energies was given in different working gases. This indicates that the GEM-Micromegas detector has an energy response capability in an energy range from 6 keV to 20 keV and it could work better than the standard bulk-Micromegas.
基金Supported by National Key Programme for S&T Research and Development(2016YFA0400400)National Natural Science Foundation of China(11275224)
文摘A new concept for a hybrid structure gaseous detector module with ion backflow suppression for the time projection chamber in a future circular collider is presented.It is a hybrid structure cascaded Gas Electron Multiplier(GEM) with a Micromegas detector.Both Micromegas and GEM have the capability to naturally reduce most of the ions produced in the amplification region.The GEM also acts as the preamplifer device and increases gas gain together with the Micromegas.Feasibility tests of the hybrid detector are performed using an ^(55)Fe X-ray source.The energy resolution is better than 27% for 5.9 keV X-rays.It is demonstrated that a backflow ratio better than 0.2% can be reached in the hybrid readout structure at a gain of 5000.