To improve the understanding of the turbulence intermittency, a detailed investigation of the intermittency of the density fluctuations has been performed in the boundary of J-TEXT. The intermittency of the density fl...To improve the understanding of the turbulence intermittency, a detailed investigation of the intermittency of the density fluctuations has been performed in the boundary of J-TEXT. The intermittency of the density fluctuations and its influence on the radial transport are reported. The probability distribution functions of the density fluctuations are not scale-invariant, being inconsistent with the self-organized criticality hypothesis. The underlying dynamics of the intermittency are detected using the quiet-time statistical method. The probability distribution function of the quiet times shows double-power-law regions, indicating the existence of correlations between the successive burst events.展开更多
A wide-viewing-angle visible light imaging system (VLIS) was mounted on the Joint Texas Experimental Tokamak (J-TEXT) to monitor the discharge process. It is proposed that by using the film data recorded the plasm...A wide-viewing-angle visible light imaging system (VLIS) was mounted on the Joint Texas Experimental Tokamak (J-TEXT) to monitor the discharge process. It is proposed that by using the film data recorded the plasma vertical displacement can be estimated. In this paper installation and operation of the VLIS are presented in detailed. The estimated result is further compared with that measured by using an array of magnetic pickup coils. Their consistency verifies that the estimation of the plasma vertical displacement in J-TEXT by using the imaging data is promising.展开更多
根据江苏电力范围内的电力电容器配置情况及设备故障缺陷数据,从电容器缺陷原因、缺陷部位、缺陷发生时间等维度,深入分析了35 k V电力电容器缺陷,总结规律,其中设备老化是故障发生的主要原因;引线接头、熔丝、电容器本体和串抗是缺陷...根据江苏电力范围内的电力电容器配置情况及设备故障缺陷数据,从电容器缺陷原因、缺陷部位、缺陷发生时间等维度,深入分析了35 k V电力电容器缺陷,总结规律,其中设备老化是故障发生的主要原因;引线接头、熔丝、电容器本体和串抗是缺陷多发部位,投运10年左右的设备缺陷较多。最后从设备采购、安装调试、运行维护、技改修理等方面提出了建议和措施,以提高电容器设备运行可靠性。展开更多
基金supported in part by the National Basic Research Program of China (Grant No. 2008CB717805)the National Natural Science Foundation of China (Grant No. 50907029)
文摘To improve the understanding of the turbulence intermittency, a detailed investigation of the intermittency of the density fluctuations has been performed in the boundary of J-TEXT. The intermittency of the density fluctuations and its influence on the radial transport are reported. The probability distribution functions of the density fluctuations are not scale-invariant, being inconsistent with the self-organized criticality hypothesis. The underlying dynamics of the intermittency are detected using the quiet-time statistical method. The probability distribution function of the quiet times shows double-power-law regions, indicating the existence of correlations between the successive burst events.
基金supported in part by the National 973 Project of China (No.2008CB717805)National Natural Science Foundation of China (No.50907029)
文摘A wide-viewing-angle visible light imaging system (VLIS) was mounted on the Joint Texas Experimental Tokamak (J-TEXT) to monitor the discharge process. It is proposed that by using the film data recorded the plasma vertical displacement can be estimated. In this paper installation and operation of the VLIS are presented in detailed. The estimated result is further compared with that measured by using an array of magnetic pickup coils. Their consistency verifies that the estimation of the plasma vertical displacement in J-TEXT by using the imaging data is promising.
文摘根据江苏电力范围内的电力电容器配置情况及设备故障缺陷数据,从电容器缺陷原因、缺陷部位、缺陷发生时间等维度,深入分析了35 k V电力电容器缺陷,总结规律,其中设备老化是故障发生的主要原因;引线接头、熔丝、电容器本体和串抗是缺陷多发部位,投运10年左右的设备缺陷较多。最后从设备采购、安装调试、运行维护、技改修理等方面提出了建议和措施,以提高电容器设备运行可靠性。