To alleviate the distortion of XRII X-ray image intensifier images in the C-arm CT computer tomography imaging system an algorithm based on the Delaunay triangulation interpolation is proposed.First the causes of the ...To alleviate the distortion of XRII X-ray image intensifier images in the C-arm CT computer tomography imaging system an algorithm based on the Delaunay triangulation interpolation is proposed.First the causes of the phenomenon the classical correction algorithms and the Delaunay triangulation interpolation are analyzed.Then the algorithm procedure is explained using flow charts and illustrations. Finally experiments are described to demonstrate its effectiveness and feasibility. Experimental results demonstrate that the Delaunay triangulation interpolation can have the following effects.In the case of the same center the root mean square distances RMSD and standard deviation STD between the corrected image with Delaunay triangulation interpolation and the ideal image are 5.760 4 ×10 -14 and 5.354 2 ×10 -14 respectively.They increase to 1.790 3 2.388 8 2.338 8 and 1.262 0 1.268 1 1.202 6 after applying the quartic polynomial model L1 and model L2 to the distorted images respectively.The RMSDs and STDs between the corrected image with the Delaunay triangulation interpolation and the ideal image are 2.489 × 10 -13 and 2.449 8 ×10 -13 when their centers do not coincide. When the quartic polynomial model L1 and model L2 are applied to the distorted images they are 1.770 3 2.388 8 2.338 8 and 1.269 9 1.268 1 1.202 6 respectively.展开更多
To solve the problem that metal artifacts severely damage the clarity of the organization structure in computed tomography(CT) images, a sinogram fusion-based metal artifact correction method is proposed. First, the...To solve the problem that metal artifacts severely damage the clarity of the organization structure in computed tomography(CT) images, a sinogram fusion-based metal artifact correction method is proposed. First, the metal image is segmented from the original CT image by the pre-set threshold. The original CT image and metal image are forward projected into the original projection sinogram and metal projection sinogram, respectively. The interpolation-based correction method and mean filter are used to correct the original CT image and preserve the edge of the corrected CT image, respectively. The filtered CT image is forward projected into the filtered image sinogram. According to the position of the metal sinogram in the original sinogram and filtered image sinogram, the corresponding sinograms PM^D ( in the original sinogram) and PM^C ( in the filtered image sinogram)can be acquired from the original sinogram and filtered image sinogram, respectively. Then, PM^D and PM^C are fused into the fused metal sinogram PM^F according to a certain proportion.The final sinogram can be acquired by fusing PM^F , PM^D and the original sinogram P^O. Finally, the final sinogram is reconstructed into the corrected CT image and metal information is compensated into the corrected CT image.Experiments on clinical images demonstrate that the proposed method can effectively reduce metal artifacts. A comparison with classical metal artifacts correction methods shows that the proposed metal artifacts correction method performs better in metal artifacts suppression and tissue feature preservation.展开更多
核密度无需估计参数及背景特征分布,可以处理复杂背景下运动目标检测,但核函数带宽的选择一直困扰着算法的应用。针对这一问题,提出人体特征和核密度估计融合方法(characteristics of body-kernel density estimation,COBKDE),用于行人...核密度无需估计参数及背景特征分布,可以处理复杂背景下运动目标检测,但核函数带宽的选择一直困扰着算法的应用。针对这一问题,提出人体特征和核密度估计融合方法(characteristics of body-kernel density estimation,COBKDE),用于行人检测。通过人体特征信息选择核函数带宽,基于核密度估计提取前景,融合人体特征检测视频行人。实验结果表明,引入人体特征信息后,该方法相比于传统方法减少了核密度估计的运算量,在受到光线变化和噪声等干扰时,能准确检测行人和非行人。该方法可以推广到车辆、动物的检测。展开更多
基金The Natural Science Foundation of Anhui Province(No.1308085MF96)the Project of Chuzhou University(No.2012qd06,2011kj010B)+1 种基金the Scientific Research Foundation of Education Department of Anhui Province(No.KJ2014A186)the National Basic Research Program of China(973 Program)(No.2010CB732503)
文摘To alleviate the distortion of XRII X-ray image intensifier images in the C-arm CT computer tomography imaging system an algorithm based on the Delaunay triangulation interpolation is proposed.First the causes of the phenomenon the classical correction algorithms and the Delaunay triangulation interpolation are analyzed.Then the algorithm procedure is explained using flow charts and illustrations. Finally experiments are described to demonstrate its effectiveness and feasibility. Experimental results demonstrate that the Delaunay triangulation interpolation can have the following effects.In the case of the same center the root mean square distances RMSD and standard deviation STD between the corrected image with Delaunay triangulation interpolation and the ideal image are 5.760 4 ×10 -14 and 5.354 2 ×10 -14 respectively.They increase to 1.790 3 2.388 8 2.338 8 and 1.262 0 1.268 1 1.202 6 after applying the quartic polynomial model L1 and model L2 to the distorted images respectively.The RMSDs and STDs between the corrected image with the Delaunay triangulation interpolation and the ideal image are 2.489 × 10 -13 and 2.449 8 ×10 -13 when their centers do not coincide. When the quartic polynomial model L1 and model L2 are applied to the distorted images they are 1.770 3 2.388 8 2.338 8 and 1.269 9 1.268 1 1.202 6 respectively.
基金Open Research Fund of the Key Laboratory of Computer Netw ork and Information Integration of Ministry of Education of Southeast University(No.K93-9-2014-10C)the Scientific Research Foundation of Education Department of Anhui Province(No.KJ2014A186,SK2015A433)the National Basic Research Program of China(973 Program)(No.2010CB732503)
文摘To solve the problem that metal artifacts severely damage the clarity of the organization structure in computed tomography(CT) images, a sinogram fusion-based metal artifact correction method is proposed. First, the metal image is segmented from the original CT image by the pre-set threshold. The original CT image and metal image are forward projected into the original projection sinogram and metal projection sinogram, respectively. The interpolation-based correction method and mean filter are used to correct the original CT image and preserve the edge of the corrected CT image, respectively. The filtered CT image is forward projected into the filtered image sinogram. According to the position of the metal sinogram in the original sinogram and filtered image sinogram, the corresponding sinograms PM^D ( in the original sinogram) and PM^C ( in the filtered image sinogram)can be acquired from the original sinogram and filtered image sinogram, respectively. Then, PM^D and PM^C are fused into the fused metal sinogram PM^F according to a certain proportion.The final sinogram can be acquired by fusing PM^F , PM^D and the original sinogram P^O. Finally, the final sinogram is reconstructed into the corrected CT image and metal information is compensated into the corrected CT image.Experiments on clinical images demonstrate that the proposed method can effectively reduce metal artifacts. A comparison with classical metal artifacts correction methods shows that the proposed metal artifacts correction method performs better in metal artifacts suppression and tissue feature preservation.
文摘核密度无需估计参数及背景特征分布,可以处理复杂背景下运动目标检测,但核函数带宽的选择一直困扰着算法的应用。针对这一问题,提出人体特征和核密度估计融合方法(characteristics of body-kernel density estimation,COBKDE),用于行人检测。通过人体特征信息选择核函数带宽,基于核密度估计提取前景,融合人体特征检测视频行人。实验结果表明,引入人体特征信息后,该方法相比于传统方法减少了核密度估计的运算量,在受到光线变化和噪声等干扰时,能准确检测行人和非行人。该方法可以推广到车辆、动物的检测。