The characteristics of surface appearances,mass loss,relative dynamic modulus of elasticity and strength loss of different recycled aggregate concretes(RAC) exposed to freeze-thaw cycles were analyzed.It was found tha...The characteristics of surface appearances,mass loss,relative dynamic modulus of elasticity and strength loss of different recycled aggregate concretes(RAC) exposed to freeze-thaw cycles were analyzed.It was found that the freeze-thaw resistance of RAC could be determined by the recycled aggregate compositions and admixtures.Both the saturation degree and the air void structure were the key factors influencing the freeze-thaw damage on concrete.Some major proposed freeze-thaw deterioration mechanisms were utilized to interpret the freeze-thaw damage on recycled aggregate concrete.Meanwhile,some potential measures to enhance the freeze-thaw resistance of concrete were summarized and discussed.展开更多
The modern transportation system is increasingly developed during recent years.It is an effective solution to set the noise barriers to reduce the traffic noise pollution caused by different kinds of transportation sy...The modern transportation system is increasingly developed during recent years.It is an effective solution to set the noise barriers to reduce the traffic noise pollution caused by different kinds of transportation systems.Many deficiencies on concrete noise barriers and metal noise barriers with rivet structure can be eliminated by a new kind of noise barrier with no-riveted structure.The mechanical performance examination and acoustic performance test are conducted on the new-designed noise barrier with no-riveted structure.The results indicate that the maximum stress is 1.74 MPa and the maximum deformation is 1.04 mm with load acting on the unit plate.The noise reduction coefficient of this kind of no-riveted noise barrier unit plate is 0.75 and its noise insulation is 40 dB,which were conform to or superior to the standard requirements.Therefore,this new designed noise barrier meets the field application requirements of mechanical and acoustic performance,which demonstrates the noise barriers can be widely promoted.展开更多
文摘以陶粒作为主要骨料,水泥为胶凝材料,并添加适量的外加剂和纤维制备的高性能地铁轨道吸音板非常适合地铁环境下的吸声降噪。试验分别对厚度,"门"型空腔,表面形态等吸声降噪方面进行优化。结果表明,厚度130 mm的吸音板在100~1800 Hz频段的降噪效果较好;在吸音板底部设置"十字"型空腔对低频的吸声性能有很大的提高;表面开槽对声波具有更充分的吸收。经过现场实测分析,吸音板降噪效果可达3~4 d B(A)。
基金Funded by the National Key Research and Development Program of China during the“13th Five-Year Plan”(No.2018 YFD1101001)。
文摘The characteristics of surface appearances,mass loss,relative dynamic modulus of elasticity and strength loss of different recycled aggregate concretes(RAC) exposed to freeze-thaw cycles were analyzed.It was found that the freeze-thaw resistance of RAC could be determined by the recycled aggregate compositions and admixtures.Both the saturation degree and the air void structure were the key factors influencing the freeze-thaw damage on concrete.Some major proposed freeze-thaw deterioration mechanisms were utilized to interpret the freeze-thaw damage on recycled aggregate concrete.Meanwhile,some potential measures to enhance the freeze-thaw resistance of concrete were summarized and discussed.
基金supported by the National Natural Science Foundation of China (No. 51768014).
文摘The modern transportation system is increasingly developed during recent years.It is an effective solution to set the noise barriers to reduce the traffic noise pollution caused by different kinds of transportation systems.Many deficiencies on concrete noise barriers and metal noise barriers with rivet structure can be eliminated by a new kind of noise barrier with no-riveted structure.The mechanical performance examination and acoustic performance test are conducted on the new-designed noise barrier with no-riveted structure.The results indicate that the maximum stress is 1.74 MPa and the maximum deformation is 1.04 mm with load acting on the unit plate.The noise reduction coefficient of this kind of no-riveted noise barrier unit plate is 0.75 and its noise insulation is 40 dB,which were conform to or superior to the standard requirements.Therefore,this new designed noise barrier meets the field application requirements of mechanical and acoustic performance,which demonstrates the noise barriers can be widely promoted.