我院使用美国Avionics Del Mar生产的TRE-NDSETTER Model DCG Ⅶ型分析仪,以佩带式磁带记录盒连续记录受检者24h日常生活中各种状态的所有心电信息,后经快速回放装置以人机结合方法逐一将所有信息进行分析,最后由电脑处理作综合结论。...我院使用美国Avionics Del Mar生产的TRE-NDSETTER Model DCG Ⅶ型分析仪,以佩带式磁带记录盒连续记录受检者24h日常生活中各种状态的所有心电信息,后经快速回放装置以人机结合方法逐一将所有信息进行分析,最后由电脑处理作综合结论。受检者系我院1983—1989年316名健康人,即常规心电图、超声心动图正常,X线无心脏增大,无高血压及糖尿病等病史,无自觉症状,部分年长者作运动试验无缺血性改变。其中男性223名,女性93名。展开更多
A total of 105 patients with idiopathic dilated cardiomyopathy (IDCM) underwent Holter monitoring. The prevalence of arrhythmias was as follows: ventricular premature beats (VPB) 100%, including complex VPB 58.1%,...A total of 105 patients with idiopathic dilated cardiomyopathy (IDCM) underwent Holter monitoring. The prevalence of arrhythmias was as follows: ventricular premature beats (VPB) 100%, including complex VPB 58.1%, short runs of ventricular tachycardia (VT) 25.7%, A-VB or BBB 46.7%, atrial arrhythmias 38.1%, sinus node dysfunction 6.6%, ST-T change 38.1%. The incidence of ventricular arrhythmia (VA) was not related to severity of cardiac dysfunction (NYHA), duration of illness and sex. The most common arrhythmia was VA, the second one was heart block and atrial arrhythmia. Serum norepinephrine and epinephrine levels were 743.4± 252.5 and 688.0± 452.4 pg/ml, respectively, which were higher than those in control group (P<0.01). Isoproterenol sensitivity test (ICD5) 8.43± 11.21 μg, was also much higher than that in control group (P<0.01).Average H-V interval was 69.4±13.3 msec in HBE. Eight patients died.Two died of congestive heart failure (class Ⅱ-Ⅳ),and six cases were diagnosed as sudden cardiac展开更多
文摘我院使用美国Avionics Del Mar生产的TRE-NDSETTER Model DCG Ⅶ型分析仪,以佩带式磁带记录盒连续记录受检者24h日常生活中各种状态的所有心电信息,后经快速回放装置以人机结合方法逐一将所有信息进行分析,最后由电脑处理作综合结论。受检者系我院1983—1989年316名健康人,即常规心电图、超声心动图正常,X线无心脏增大,无高血压及糖尿病等病史,无自觉症状,部分年长者作运动试验无缺血性改变。其中男性223名,女性93名。
文摘A total of 105 patients with idiopathic dilated cardiomyopathy (IDCM) underwent Holter monitoring. The prevalence of arrhythmias was as follows: ventricular premature beats (VPB) 100%, including complex VPB 58.1%, short runs of ventricular tachycardia (VT) 25.7%, A-VB or BBB 46.7%, atrial arrhythmias 38.1%, sinus node dysfunction 6.6%, ST-T change 38.1%. The incidence of ventricular arrhythmia (VA) was not related to severity of cardiac dysfunction (NYHA), duration of illness and sex. The most common arrhythmia was VA, the second one was heart block and atrial arrhythmia. Serum norepinephrine and epinephrine levels were 743.4± 252.5 and 688.0± 452.4 pg/ml, respectively, which were higher than those in control group (P<0.01). Isoproterenol sensitivity test (ICD5) 8.43± 11.21 μg, was also much higher than that in control group (P<0.01).Average H-V interval was 69.4±13.3 msec in HBE. Eight patients died.Two died of congestive heart failure (class Ⅱ-Ⅳ),and six cases were diagnosed as sudden cardiac