期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Establishment of a Refined Brain Model for Evaluating Implantation Behavior of Neural Electrode and Research of its Simulated Behavior 被引量:1
1
作者 贺雨欣 张文光 +2 位作者 胥浩天 徐倚帆 许李悦 《Journal of Shanghai Jiaotong university(Science)》 EI 2023年第4期401-410,共10页
The long-term reliability of the neural electrode is closely related to its implantation behavior.In orderto realize the quantitative research of the implantation behavior in a low-cost and accurate way,a refined brai... The long-term reliability of the neural electrode is closely related to its implantation behavior.In orderto realize the quantitative research of the implantation behavior in a low-cost and accurate way,a refined brainmodel containing meninges is proposed.First,the expected simulation material was selected through measuringthe elastic modulus based on the method of atomic force microscope indentation technique.As a result,the 2%(mass fraction)agarose gel simulated the gray and white matter,the 7:1(volume ratio)polydimethylsiloxane(PDMS)sheet simulated the pia mater,and the polyvinyl chloride(PVC)film simulated the dura mater.Second,based on designing a three-layer structure mold,the brain model was prepared by inverted pouring to realizea flat implantation surface.Finally,the simulation behavior of the brain model was investigated with the ratbrain as a reference.For mechanical behavior of implantation,the implantation force experienced two peaks bothin the brain model and the rat brain,maximum values of which were 10.17 mN and 7.69 mN respectively.Thelarger implantation force in the brain model will increase the strength requirement for the electrode,but reducethe risk of buckling of that in practical application.For humoral dissolution behavior,the dissolution rates ofthe polyethylene glycol(PEG)coating of the electrode in the brain model and rat brain were 7000μm3/s and5600μm3/s,respectively.The faster dissolution rate in the brain model will cause the larger thickness of thecoating design but provide sufficient implantable time in practical application.The establishment of the brainmodel and the research of its simulated behavior are beneficial to the size design of the electrode substrate andcoating,and research of the implantation mechanism,and further increase the functional life of the electrode. 展开更多
关键词 neural electrode brain model implantation behavior
原文传递
柔性神经电极植入工具的振动植入参数研究
2
作者 胥浩天 张文光 +1 位作者 贺雨欣 许李悦 《华中科技大学学报(自然科学版)》 EI CAS CSCD 北大核心 2022年第12期89-97,共9页
为了分析振动植入中各振动参数对柔性神经电极辅助植入工具植入过程的影响,基于受迫振动及黏弹性材料的理论基础,通过运动学和黏弹性力学方法分析了振动中频率、振幅、振动波形对植入过程的影响;提出了穿刺能量这一植入过程评价指标,其... 为了分析振动植入中各振动参数对柔性神经电极辅助植入工具植入过程的影响,基于受迫振动及黏弹性材料的理论基础,通过运动学和黏弹性力学方法分析了振动中频率、振幅、振动波形对植入过程的影响;提出了穿刺能量这一植入过程评价指标,其更加直观反映被植入组织的损伤情况;最后,通过体外脑组织模型植入实验对理论分析结果进行了验证.实验结果表明:对各个振动参数影响的理论分析与实验结果基本相符,振动植入能降低植入中的穿刺力及穿刺能量,并且通过提高振幅及采用锯齿波进行触发,进一步降低植入过程的穿刺力及穿刺能量. 展开更多
关键词 柔性神经电极 振动 穿刺力 穿刺能量 组织切割
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部