The focused acoustic field generated by an annular array interface are investigated theoretically and experimentally. transducer and its reflection field on a solid-liquid Theoretically, the concise analytic expressio...The focused acoustic field generated by an annular array interface are investigated theoretically and experimentally. transducer and its reflection field on a solid-liquid Theoretically, the concise analytic expressions about the radiation and reflection acoustic fields of the annular phased array are obtained by the ray approach method (saddle-point method). In experiment, an annular transducer with 8 equal-area elements is designed and fabricated, and a series of experiments about the radiation acoustic field and its reflection on the liquid-solid interface are carried out. The experimental characteristics of the transducer are in good agreement with the numerical ones. It shows the correctness of the theoretical result and the feasibility of dynamic focusing of the experiment system. With the maximum amplitude and its emergence time of the reflection wave, we can acquire the information and the imaging of the reflection interface by the annular phased array dynamic focusing.展开更多
基金国家自然科学基金(81930048)国家自然科学基金优秀青年科学基金(62105353)+3 种基金广东省自然科学基金(2019A1515011374,2019BT02X105,2020B121201010)香港Research Grant Council(15217721,C7074-21GF,R5029-19)香港创新科技署深港联合创新圈项目(GHP/043/19 SZ)香港创新科技署粤港联合创新圈项目(GHP/044/19GD)。
基金Supported by the National Natural Science Foundation of China under Grant No 10134020.
文摘The focused acoustic field generated by an annular array interface are investigated theoretically and experimentally. transducer and its reflection field on a solid-liquid Theoretically, the concise analytic expressions about the radiation and reflection acoustic fields of the annular phased array are obtained by the ray approach method (saddle-point method). In experiment, an annular transducer with 8 equal-area elements is designed and fabricated, and a series of experiments about the radiation acoustic field and its reflection on the liquid-solid interface are carried out. The experimental characteristics of the transducer are in good agreement with the numerical ones. It shows the correctness of the theoretical result and the feasibility of dynamic focusing of the experiment system. With the maximum amplitude and its emergence time of the reflection wave, we can acquire the information and the imaging of the reflection interface by the annular phased array dynamic focusing.