In order to optimize the laser ablation performance of a micro-thruster with 1U dimensions,which employs a micro semiconductor laser,the impacts of pulse width and glycidyl azide polymer(GAP)thickness on thrust perfor...In order to optimize the laser ablation performance of a micro-thruster with 1U dimensions,which employs a micro semiconductor laser,the impacts of pulse width and glycidyl azide polymer(GAP)thickness on thrust performance were researched.The results showed that with a GAP thickness of 200μm,the single-pulse impulse(I)increased gradually with the increase in the laser pulse width from 50 to 800μs,while the specific impulse(I_(sp)),impulse coupling coefficient(Cm)and ablation efficiency(η)all reached optimal values with a 200μs pulse width.It is worth noting that the optimal pulse width is identical to the ignition delay time.Both Cmandηpeaked with a pulse width of 200μs,reaching 242.22μN W^(-1)and 35.4%,respectively.With the increase in GAP thickness,I and Cmincreased gradually.GAP of different thicknesses corresponded to different optimal laser pulse widths.Under a certain laser pulse width,the optimal GAP thickness should be the most vertical thickness of the ablation pit,and the various propulsion performance parameters at this time were also optimal.With the current laser parameters,the optimal GAP thickness was approximately 150μm,I_(sp)was approximately 322.22 s,andηwas approximately 34.94%.展开更多
基金supported by National Natural Science Foundation of China (Nos. 11502301, 11602304 and 62175260)
文摘In order to optimize the laser ablation performance of a micro-thruster with 1U dimensions,which employs a micro semiconductor laser,the impacts of pulse width and glycidyl azide polymer(GAP)thickness on thrust performance were researched.The results showed that with a GAP thickness of 200μm,the single-pulse impulse(I)increased gradually with the increase in the laser pulse width from 50 to 800μs,while the specific impulse(I_(sp)),impulse coupling coefficient(Cm)and ablation efficiency(η)all reached optimal values with a 200μs pulse width.It is worth noting that the optimal pulse width is identical to the ignition delay time.Both Cmandηpeaked with a pulse width of 200μs,reaching 242.22μN W^(-1)and 35.4%,respectively.With the increase in GAP thickness,I and Cmincreased gradually.GAP of different thicknesses corresponded to different optimal laser pulse widths.Under a certain laser pulse width,the optimal GAP thickness should be the most vertical thickness of the ablation pit,and the various propulsion performance parameters at this time were also optimal.With the current laser parameters,the optimal GAP thickness was approximately 150μm,I_(sp)was approximately 322.22 s,andηwas approximately 34.94%.