With the constant increase of accelerator luminosity, the rate requirements of MRPC detectors have become very important, and the aging characteristics of the detector have to be studied meticulously. An online aging ...With the constant increase of accelerator luminosity, the rate requirements of MRPC detectors have become very important, and the aging characteristics of the detector have to be studied meticulously. An online aging test system has been set up in our lab, and in this paper the setupof the system is described and the performance stability of a high-rate MRPC studied over a long running time under a high luminosity environment. The high rate MRPC was irradiated by X-rays for 36 days and the accumulated charge density reached 0.1 C/cm2. No obvious performance degradation was observed for the detector.展开更多
The Compact Muon Solenoid (CMS) at LHC intends to use a high rate trapezoid MRPC for the muon system upgrade, but the size of the MRPC is limited by the dimensions of low resistivity glass. We have designed a protot...The Compact Muon Solenoid (CMS) at LHC intends to use a high rate trapezoid MRPC for the muon system upgrade, but the size of the MRPC is limited by the dimensions of low resistivity glass. We have designed a prototype of a large MRPC in which the electrodes are developed by gluing two pieces of glass plates. Simulation of the weighting field and cosmic ray test shows that the efficiency of the glued MRPC is higher than 96% and the time resolution is better than 71 ps.展开更多
基金Supported by National Natural Science Foundation of China(11420101004,11461141011,11275108)Ministry of Science and Technology(2015CB856905)
文摘With the constant increase of accelerator luminosity, the rate requirements of MRPC detectors have become very important, and the aging characteristics of the detector have to be studied meticulously. An online aging test system has been set up in our lab, and in this paper the setupof the system is described and the performance stability of a high-rate MRPC studied over a long running time under a high luminosity environment. The high rate MRPC was irradiated by X-rays for 36 days and the accumulated charge density reached 0.1 C/cm2. No obvious performance degradation was observed for the detector.
基金Supported by National Natural Science Foundation of China(11420101004,11461141011,11275108)Ministry of Science and Technology(2015CB856905)
文摘The Compact Muon Solenoid (CMS) at LHC intends to use a high rate trapezoid MRPC for the muon system upgrade, but the size of the MRPC is limited by the dimensions of low resistivity glass. We have designed a prototype of a large MRPC in which the electrodes are developed by gluing two pieces of glass plates. Simulation of the weighting field and cosmic ray test shows that the efficiency of the glued MRPC is higher than 96% and the time resolution is better than 71 ps.