We demonstrate a simple scheme of 6.835 GHz microwave source based on the sub-sampling phase lock loop(PLL). A dielectric resonant oscillator of 6.8 GHz is directly phase locked to an ultra-low phase noise 100 MHz ove...We demonstrate a simple scheme of 6.835 GHz microwave source based on the sub-sampling phase lock loop(PLL). A dielectric resonant oscillator of 6.8 GHz is directly phase locked to an ultra-low phase noise 100 MHz oven controlled crystal oscillator(OCXO) utilizing the sub-sampling PLL. Then the 6.8 GHz is mixed with 35 MHz from an direct digital synthesizer(DDS) which is also referenced to the 100 MHZ OCXO to generate the final6.835 GHz signal. Benefiting from the sub-sampling PLL, the processes of frequency multiplication, which are usually necessary in the development of a microwave source, are greatly simplified. The architecture of the microwave source is pretty simple. Correspondingly, its power consumption and cost are low. The absolute phase noises of the 6.835 GHz output signal are-47 d Bc/Hz,-77 dBc/Hz,-104 dBc/Hz and-121 dBc/Hz at1 Hz, 10 Hz, 100 Hz and 1 kHz offset frequencies, respectively. The frequency stability limited by the phase noise through the Dick effect is theoretically estimated to be better than 5.0 × 10^-14τ^1/2 when it is used as the local oscillator of the Rb atomic clocks. This low phase noise microwave source can also be used in other experiments of precision measurement physics.展开更多
We report construction of an iodine-stabilized laser frequency standard at 532 nm based on modulation transfer spectroscopy(MTS)technology with good reproducibility.A frequency stability of 2.5×10^(-14)at 1 s ave...We report construction of an iodine-stabilized laser frequency standard at 532 nm based on modulation transfer spectroscopy(MTS)technology with good reproducibility.A frequency stability of 2.5×10^(-14)at 1 s averaging time is achieved,and the frequency reproducibility has a relative uncertainty of 3.5×10^(-13),demonstrating the great stability of our setup.The systematic uncertainty of the iodine-stabilized laser frequency standard is evaluated,especially the contribution of the residual amplitude modulation(RAM).The contribution of the RAM in MTS cannot be evaluated directly.To solve this problem,we theoretically deduce the MTS signal with RAM under large modulation depth,and prove that the non-symmetric shape of the MTS signal is directly related to the MTS effect.The non-symmetric shape factor can be calibrated with a frequency comb,and in real experiments,this value can be obtained by least-squares fitting of the MTS signal,from which we can infer the RAMinduced frequency shift.The full frequency uncertainty is evaluated to be 5.3 kHz(corresponding to a relative frequency uncertainty of 9.4×10^(-12)).The corrected transition frequency has a difference from the BIPM-recommended value of 2 kHz,which is within 1σ uncertainty,proving the validity of our evaluation.展开更多
The Al^+ ion optical clock is a very promising optical frequency standard candidate due to its extremely small black-body radiation shift. It has been successfully demonstrated with the indirect cooled, quantum-logic...The Al^+ ion optical clock is a very promising optical frequency standard candidate due to its extremely small black-body radiation shift. It has been successfully demonstrated with the indirect cooled, quantum-logic-based spectroscopy technique. Its accuracy is limited by second-order Doppler shift, and its stability is limited by the number of ions that can be probed in quantum logic processing. We propose a direct laser cooling scheme of AI+ ion optical clocks where both the stability and accuracy of the clocks are greatly improved. In the proposed scheme, two Al^+ traps are utilized. The first trap is used to trap a large number of Al^+ ions to improve the stability of the clock laser, while the second trap is used to trap a single Al^+ ion to provide the ultimate accuracy. Both traps are cooled with a continuous wave 167nm laser. The expected clock laser stability can reach 9.0 × 10^-17/√τ. For the second trap, in addition to 167nm laser Doppler cooling, a second stage pulsed 234nm two-photon cooling laser is utilized to further improve the accuracy of the clock laser. The total systematic uncertainty can be reduced to about 1 × 10^-18. The proposed Al^+ ion optical clock has the potential to become the most accurate and stable optical clock.展开更多
基金Supported by the National Key Research and Development Program of China under Grant No 2017YFA0304400the National Natural Science Foundation of China under Grant Nos 91336213,11703031,U1731132 and 11774108
文摘We demonstrate a simple scheme of 6.835 GHz microwave source based on the sub-sampling phase lock loop(PLL). A dielectric resonant oscillator of 6.8 GHz is directly phase locked to an ultra-low phase noise 100 MHz oven controlled crystal oscillator(OCXO) utilizing the sub-sampling PLL. Then the 6.8 GHz is mixed with 35 MHz from an direct digital synthesizer(DDS) which is also referenced to the 100 MHZ OCXO to generate the final6.835 GHz signal. Benefiting from the sub-sampling PLL, the processes of frequency multiplication, which are usually necessary in the development of a microwave source, are greatly simplified. The architecture of the microwave source is pretty simple. Correspondingly, its power consumption and cost are low. The absolute phase noises of the 6.835 GHz output signal are-47 d Bc/Hz,-77 dBc/Hz,-104 dBc/Hz and-121 dBc/Hz at1 Hz, 10 Hz, 100 Hz and 1 kHz offset frequencies, respectively. The frequency stability limited by the phase noise through the Dick effect is theoretically estimated to be better than 5.0 × 10^-14τ^1/2 when it is used as the local oscillator of the Rb atomic clocks. This low phase noise microwave source can also be used in other experiments of precision measurement physics.
基金the National Key Research and Development Program of China(Grant No.2017YFA0304401)Key-Area Research and Development Program of GuangDong Province,China(Grant No.2019B030330001)the National Natural Science Foundation of China(Grant Nos.11174095,61875065,91536116,and 11804108).
文摘We report construction of an iodine-stabilized laser frequency standard at 532 nm based on modulation transfer spectroscopy(MTS)technology with good reproducibility.A frequency stability of 2.5×10^(-14)at 1 s averaging time is achieved,and the frequency reproducibility has a relative uncertainty of 3.5×10^(-13),demonstrating the great stability of our setup.The systematic uncertainty of the iodine-stabilized laser frequency standard is evaluated,especially the contribution of the residual amplitude modulation(RAM).The contribution of the RAM in MTS cannot be evaluated directly.To solve this problem,we theoretically deduce the MTS signal with RAM under large modulation depth,and prove that the non-symmetric shape of the MTS signal is directly related to the MTS effect.The non-symmetric shape factor can be calibrated with a frequency comb,and in real experiments,this value can be obtained by least-squares fitting of the MTS signal,from which we can infer the RAMinduced frequency shift.The full frequency uncertainty is evaluated to be 5.3 kHz(corresponding to a relative frequency uncertainty of 9.4×10^(-12)).The corrected transition frequency has a difference from the BIPM-recommended value of 2 kHz,which is within 1σ uncertainty,proving the validity of our evaluation.
基金Supported by the National Basic Research Program of China under Grant No 2012CB821300the National Natural Science Foundation of China under Grant Nos 91336213,11304109,91536116 and 11174095the Program for New Century Excellent Talents by the Ministry of Education under Grant No NCET-11-0176
文摘The Al^+ ion optical clock is a very promising optical frequency standard candidate due to its extremely small black-body radiation shift. It has been successfully demonstrated with the indirect cooled, quantum-logic-based spectroscopy technique. Its accuracy is limited by second-order Doppler shift, and its stability is limited by the number of ions that can be probed in quantum logic processing. We propose a direct laser cooling scheme of AI+ ion optical clocks where both the stability and accuracy of the clocks are greatly improved. In the proposed scheme, two Al^+ traps are utilized. The first trap is used to trap a large number of Al^+ ions to improve the stability of the clock laser, while the second trap is used to trap a single Al^+ ion to provide the ultimate accuracy. Both traps are cooled with a continuous wave 167nm laser. The expected clock laser stability can reach 9.0 × 10^-17/√τ. For the second trap, in addition to 167nm laser Doppler cooling, a second stage pulsed 234nm two-photon cooling laser is utilized to further improve the accuracy of the clock laser. The total systematic uncertainty can be reduced to about 1 × 10^-18. The proposed Al^+ ion optical clock has the potential to become the most accurate and stable optical clock.