The Ex-PRESS (Optonol Ltd.) is a miniature stainless steel glaucoma implant with a 50-micron internal lumen. A single-center, open, non-comparative case series was performed to evaluate the safety and efficacy of the ...The Ex-PRESS (Optonol Ltd.) is a miniature stainless steel glaucoma implant with a 50-micron internal lumen. A single-center, open, non-comparative case series was performed to evaluate the safety and efficacy of the Ex-PRESS in reducing IOP in open angle glaucoma patients. Thirty-six Caucasian patients with OAG and vision impairing cataract were展开更多
Aim: To study prospectively the success rate and complications of deep sclerectomy with collagen implant (DSCI). Setting: Glaucoma unit, Department of Ophthalmology, H? Oph-talmique Jules Gonin, University of Lausanne...Aim: To study prospectively the success rate and complications of deep sclerectomy with collagen implant (DSCI). Setting: Glaucoma unit, Department of Ophthalmology, H? Oph-talmique Jules Gonin, University of Lausanne, Lausanne , Switzerland. Methods: Non-randomised prospective trial involving 105 eyes of 105 patients with medically uncontrolled 1ry展开更多
Purpose: To study prospectively the possibilty of using intraocular pressure(IOP) in the first postoperative day after deep scle-rectomy as a prognostic indicator. Methods: Non-randomised prospective trial involving 1...Purpose: To study prospectively the possibilty of using intraocular pressure(IOP) in the first postoperative day after deep scle-rectomy as a prognostic indicator. Methods: Non-randomised prospective trial involving 105eyes of 105patients with medically uncontrolled primary and secondary open-angle glaucoma, Visu-展开更多
Purpose: To compare the efficacy and longevity of Non-Penetrating Glaucoma Surgery (NPGS) with & without the use of a non-absorbable hydrophilic implant. Methods: 48 eyes of 32 patients aged 18-86 years, with POAG...Purpose: To compare the efficacy and longevity of Non-Penetrating Glaucoma Surgery (NPGS) with & without the use of a non-absorbable hydrophilic implant. Methods: 48 eyes of 32 patients aged 18-86 years, with POAG, underwent NPGS; 25 eyes with the non-absorbable hydrophilic implant T Flux and 23 eyes without it. Results: The mean preoperative IOP dropped from 27.5mmHg±11.8 (SD) to 12.5mmHg ±2.7 in the T展开更多
Purpose: to study morphological changes in the endothelium of Schlemm's canal in glaucomatous patients compared to normals. Method: scanning electronmicroscopy of the inner portion of Schlemm's canal peeled du...Purpose: to study morphological changes in the endothelium of Schlemm's canal in glaucomatous patients compared to normals. Method: scanning electronmicroscopy of the inner portion of Schlemm's canal peeled during non-penetrating surgery was studied and compared with the same tissue of normal donor eyes. Results: the anatomy of normal Schlemm's canal shows a展开更多
Purpose: The aim of this study was to understand the long-term outflow pathway mechanisms after deep sclerectomy. Methods: 42 eyes of 32 patients with medically uncontrolled open-angle glaucoma at least 1 year after d...Purpose: The aim of this study was to understand the long-term outflow pathway mechanisms after deep sclerectomy. Methods: 42 eyes of 32 patients with medically uncontrolled open-angle glaucoma at least 1 year after deep sclerectomy were studied. Postoperatively 15 eyes (35.7%) had goniopuncture. Four eyes (9.5%) had postoperative subconjunctival injections of mit-展开更多
文摘The Ex-PRESS (Optonol Ltd.) is a miniature stainless steel glaucoma implant with a 50-micron internal lumen. A single-center, open, non-comparative case series was performed to evaluate the safety and efficacy of the Ex-PRESS in reducing IOP in open angle glaucoma patients. Thirty-six Caucasian patients with OAG and vision impairing cataract were
文摘Aim: To study prospectively the success rate and complications of deep sclerectomy with collagen implant (DSCI). Setting: Glaucoma unit, Department of Ophthalmology, H? Oph-talmique Jules Gonin, University of Lausanne, Lausanne , Switzerland. Methods: Non-randomised prospective trial involving 105 eyes of 105 patients with medically uncontrolled 1ry
文摘Purpose: To study prospectively the possibilty of using intraocular pressure(IOP) in the first postoperative day after deep scle-rectomy as a prognostic indicator. Methods: Non-randomised prospective trial involving 105eyes of 105patients with medically uncontrolled primary and secondary open-angle glaucoma, Visu-
文摘Purpose: To compare the efficacy and longevity of Non-Penetrating Glaucoma Surgery (NPGS) with & without the use of a non-absorbable hydrophilic implant. Methods: 48 eyes of 32 patients aged 18-86 years, with POAG, underwent NPGS; 25 eyes with the non-absorbable hydrophilic implant T Flux and 23 eyes without it. Results: The mean preoperative IOP dropped from 27.5mmHg±11.8 (SD) to 12.5mmHg ±2.7 in the T
文摘Purpose: to study morphological changes in the endothelium of Schlemm's canal in glaucomatous patients compared to normals. Method: scanning electronmicroscopy of the inner portion of Schlemm's canal peeled during non-penetrating surgery was studied and compared with the same tissue of normal donor eyes. Results: the anatomy of normal Schlemm's canal shows a
文摘Purpose: The aim of this study was to understand the long-term outflow pathway mechanisms after deep sclerectomy. Methods: 42 eyes of 32 patients with medically uncontrolled open-angle glaucoma at least 1 year after deep sclerectomy were studied. Postoperatively 15 eyes (35.7%) had goniopuncture. Four eyes (9.5%) had postoperative subconjunctival injections of mit-