Mixed mesophilic and extreme thermophilic bioleaching were evaluated to remove copper from the molybdenite concentrate.Bioleaching tests were carried out in shake flasks and in a 50-L bioreactor.The shake flask tests ...Mixed mesophilic and extreme thermophilic bioleaching were evaluated to remove copper from the molybdenite concentrate.Bioleaching tests were carried out in shake flasks and in a 50-L bioreactor.The shake flask tests were performed with different inoculum size,solids density,pH.and temperature in order to identify optimum conditions.The highest amount of copper elimination,75%was obtained with extreme thermophilic microorganisms(at 12%inoculation,10%solids,65℃and a pH of 1.5).The highest copper elimination by mesophilic microorganisms was 55%(at 12%inoculation,5%solids,30℃at pH 2).The optimum conditions in shake flask tests were applied to 7 days batch tests in a50-L bioreactor.Extreme thermophilic experiment gave the best copper elimination of 60%(at 12%inoculation,10%solids,65℃and pH 1.5).Mesophilic test removed 50%of the copper(at 12%inoculation,10%solids,35℃at pH 2).展开更多
This study discussed the application of response surface methodology(RSM)and central composite rotatable design(CCRD)for modeling and optimization of the influence of some operating variables on the performance of a l...This study discussed the application of response surface methodology(RSM)and central composite rotatable design(CCRD)for modeling and optimization of the influence of some operating variables on the performance of a lab scale thickener for dewatering of tailing in the flotation circuit.Four thickener operating variables,namely feed flowrate,solid percent,flocculant dosage and feedwell height were changed during the tests based on CCRD.The ranges of values of the thickener variables used in the design were a feed flowrate of 9–21 L/min,solid percent of 8%–20%,flocculant dosage of 1.25–4.25 g/t and feedwell height of 16–26 cm.A total of 30 thickening tests were conducted using lab scale thickener on flotation tailing obtained from the Sarcheshmeh copper mine,Iran.The underflow solid percent and bed height were expressed as functions of four operating parameters of thickener.Predicted values were found to be in good agreement with experimental values(R2values of 0.992 and 0.997 for underflow solid percent and bed height,respectively).This study has shown that the RSM and CCRD could effciently be applied for the modeling of thickener for dewatering of flotation tailing.展开更多
基金supported by the National Iranian Copper Industry Co.
文摘Mixed mesophilic and extreme thermophilic bioleaching were evaluated to remove copper from the molybdenite concentrate.Bioleaching tests were carried out in shake flasks and in a 50-L bioreactor.The shake flask tests were performed with different inoculum size,solids density,pH.and temperature in order to identify optimum conditions.The highest amount of copper elimination,75%was obtained with extreme thermophilic microorganisms(at 12%inoculation,10%solids,65℃and a pH of 1.5).The highest copper elimination by mesophilic microorganisms was 55%(at 12%inoculation,5%solids,30℃at pH 2).The optimum conditions in shake flask tests were applied to 7 days batch tests in a50-L bioreactor.Extreme thermophilic experiment gave the best copper elimination of 60%(at 12%inoculation,10%solids,65℃and pH 1.5).Mesophilic test removed 50%of the copper(at 12%inoculation,10%solids,35℃at pH 2).
基金supported by the National Iranian Copper Industry Co.
文摘This study discussed the application of response surface methodology(RSM)and central composite rotatable design(CCRD)for modeling and optimization of the influence of some operating variables on the performance of a lab scale thickener for dewatering of tailing in the flotation circuit.Four thickener operating variables,namely feed flowrate,solid percent,flocculant dosage and feedwell height were changed during the tests based on CCRD.The ranges of values of the thickener variables used in the design were a feed flowrate of 9–21 L/min,solid percent of 8%–20%,flocculant dosage of 1.25–4.25 g/t and feedwell height of 16–26 cm.A total of 30 thickening tests were conducted using lab scale thickener on flotation tailing obtained from the Sarcheshmeh copper mine,Iran.The underflow solid percent and bed height were expressed as functions of four operating parameters of thickener.Predicted values were found to be in good agreement with experimental values(R2values of 0.992 and 0.997 for underflow solid percent and bed height,respectively).This study has shown that the RSM and CCRD could effciently be applied for the modeling of thickener for dewatering of flotation tailing.