期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Simple LC Isocratic Methods Development, Validation, and Application in the Analysis of Poor Quality Antimalarial Medicines
1
作者 Védaste Habyalimana Jérémie Kindenge Mbinze +3 位作者 achille loconon yemoa Justin-Léonard Kadima Ntokamunda Philippe Hubert Roland Marini Djang’eing’a 《American Journal of Analytical Chemistry》 2017年第9期582-603,共22页
Liquid chromatographic methods in isocratic mode for the analysis of poor quality medicines are privileged due to their simplicity and facility in methods development. They are generally fast;do not need to be re-equi... Liquid chromatographic methods in isocratic mode for the analysis of poor quality medicines are privileged due to their simplicity and facility in methods development. They are generally fast;do not need to be re-equilibrated between sample injections;have larger flexibility with acceptable changes on different column dimensions;and are applicable to LC systems equipped with simple or high developed pumps. In this study, we focused on developing simple isocratic methods using classical mobile phase composed by methanol and ammonium formate buffer for the analysis of most common antimalarial medicines marketed in malaria endemic countries and susceptible of being counterfeit/falsified, substandard and degraded. The selected medicines were quinine and related cinchona alkaloids in tablets and injectable forms;artemether/lumefantrine tablets;and artemisinin compounds (arteether, artemether, and artesunate) in injectable forms. The current methods were developed thanks to simple methodological approach consisting in sequential isocratic runs through adjustment or adaptation of existing methods to obtain optimal analytical conditions without complex design of experiments that might be long and costly. Then, the new methods presented shorter analysis time;allowed increase of sample analysis throughput;and obviously consumed little mobile phase solvents on classical analytical columns: 50 - 250 mm of length (L), 4.6 mm of internal diameter (I.D.), and 3.5 - 5.0 μm of particle size (dp). 展开更多
关键词 ANTIMALARIAL MEDICINES Liquid Chromatography ISOCRATIC Mode VALIDATION POOR QUALITY MEDICINES
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部