期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Interspinous Process Implants Causes Wear of the Spinous Processes in Patients Treated for Spinal Stenosis—An Experimental Biomechanical Study with Comparison to Clinical Cases
1
作者 adad baranto Christian Hagelberg +3 位作者 Jonas Hvannberg Lars Ekström Klas Halldin Helena Brisby 《Open Journal of Orthopedics》 2016年第7期201-210,共10页
There are few biomechanical studies on Interspinous Process Implants (IPD);however none investigate the amount of wear on spinous processes. Therefore the objective of the present study was to investigate the effect o... There are few biomechanical studies on Interspinous Process Implants (IPD);however none investigate the amount of wear on spinous processes. Therefore the objective of the present study was to investigate the effect of repetitive loading of the IPD Aperius on the spinous processes in a biomechanical porcine model. For comparison, three patients treated surgically with the same device have been followed for one to two years clinically and with image analyses (X-rays, MRI, CT-scans). Four lumbar spines from 6 months old porcine were divided into seven segments, which received IPD. The segments were exposed to 20,000 cyclical loads. Afterwards the deformation (wear) of the segments was registered. The wear of the spinous processes was measured in mm on a following CT-scan. Additionally, the wear of the ex-vivo was compared to that of the spinous processes investigated by CT-scans or X-ray in three patients treated surgically with the same interspinous implant. The mean maximal deformation of porcine specimens was 1.79 mm (SD 0.25) with the largest deformation occurring in the first quarter of the loading (<5000 cycles). The mean wear of the spinous processes after loading was 6.57 mm. A similar level of wear (mean 12.7 mm) of the spinous processes was detected in the patients. The Aperius IPD creates significant wear on the spinous processes in an experimental biomechanical study. Similar wear of the spinous processes is also present in patients treated with the same device post-operatively. How these findings influence the short and long term result of this implant device remains to be investigated in further biomechanical as well as clinical studies. For future development of this type of devices a proper selection of materials and design is essential to minimize wear effects on the spinous processes and thereby increases the possibilities for the devices to function as suggested. 展开更多
关键词 PORCINE Interspinous Process Device Cyclic Loading WEAR Degenerative Lumbar Spinal Canal Stenos Aperius PercLID
下载PDF
A Flat Sagittal Spinal Alignment Is Common among Young Patients with Lumbar Disc Herniation
2
作者 Olof Thoreson Joel Beck +2 位作者 Klas Halldin Helena Brisby adad baranto 《Open Journal of Orthopedics》 2016年第9期294-304,共12页
Background: Recent studies suggest a correlation between spinal sagittal alignment and different types of lumbar pathologies due to different load patterns on the lumbar spine. The main objective of this study was to ... Background: Recent studies suggest a correlation between spinal sagittal alignment and different types of lumbar pathologies due to different load patterns on the lumbar spine. The main objective of this study was to investigate the preoperative spinal sagittal alignment in young patients (Methods: Information regarding preoperative clinical examinations was collected from the patient medical charts. Preoperative MRI examinations were used to classify lumbar types according to four sagittal spinal alignment groups (1: a long thoracic kyphosis, 2: a flat back, 3: a normal spine and 4: an increased thoracic kyphosis). Other MRI findings were also noted. Classification of lumbar types was performed independently by three spine surgeons. To compare two sample proportions the 2-sample z-test was performed. Results: The distribution of lumbar curve types was: Type 1, 17% (9 patients);Type 2, 62% (33 patients);Type 3, 17% (9 patients) and Type 4, 4% (2 patients). The distribution of operated levels was: L3 - L4, 2% (1 patient);L4 - L5, 47% (25 patients);L5 - S1, 42% (22 patients) and L4 - L5 + L5 - S1, 9% (5 patients). Conclusions: A majority of the young patients (62%) that underwent surgery due to herniated disc in the lumbar spine were classified as Type 2 indicating a flat back. Future studies are needed to increase the knowledge about spinopelvic sagittal alignment and the correlation to spinal pathologies. 展开更多
关键词 Intervertebral Disc Displacement Sagittal Alignment SPINE SURGERY Young Adult
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部