Scanning probe microscopy(SPM)is a branch of microscopy that forms images of surfaces using a physical probe that scans the specimen.Atomic force microscopy is one of the SPM family which is considered as a very versa...Scanning probe microscopy(SPM)is a branch of microscopy that forms images of surfaces using a physical probe that scans the specimen.Atomic force microscopy is one of the SPM family which is considered as a very versatile tool for surface imaging and measurements.A wide range of various samples can be measured regardless of being conductive,no-conductive,in vacuum,in air or in a fluid as a unique feature.One of the most challenges in atomic force microscopes(AFMs)is to evaluate the associated uncertainty during the surface measurements by AFMs.Here,an optical AFM is calibrated through the calibration of XYZ stage.The approach is to overcome difficulties experienced when trying to evaluate some uncertainty components which cannot be experimentally determined i.e.tip surface interaction forces and tip geometry.The Monte Carlo method is then used to determine the associated uncertainties due to such factors by randomly drawing the parameters according to their associated tolerances and their probability density functions(PDFs).The whole process follows supplement 2 to“the guide to the expression of the uncertainty in measurement”(GUM).The approach validated in the paper shows that the evaluated uncertainty in AFM is about 10 nm.展开更多
基金National Institute of Standards(NIS),11211,Egypt。
文摘Scanning probe microscopy(SPM)is a branch of microscopy that forms images of surfaces using a physical probe that scans the specimen.Atomic force microscopy is one of the SPM family which is considered as a very versatile tool for surface imaging and measurements.A wide range of various samples can be measured regardless of being conductive,no-conductive,in vacuum,in air or in a fluid as a unique feature.One of the most challenges in atomic force microscopes(AFMs)is to evaluate the associated uncertainty during the surface measurements by AFMs.Here,an optical AFM is calibrated through the calibration of XYZ stage.The approach is to overcome difficulties experienced when trying to evaluate some uncertainty components which cannot be experimentally determined i.e.tip surface interaction forces and tip geometry.The Monte Carlo method is then used to determine the associated uncertainties due to such factors by randomly drawing the parameters according to their associated tolerances and their probability density functions(PDFs).The whole process follows supplement 2 to“the guide to the expression of the uncertainty in measurement”(GUM).The approach validated in the paper shows that the evaluated uncertainty in AFM is about 10 nm.