Effects of Beam Startup Characteristics on Dose Delivery Accuracy at Low Monitor Units in Step-and-Shoot Intensity Modulated Radiation Therapy 被引量:2
1
作者 Kazunori Fujimoto Kunihiko Tateoka +12 位作者 Yuji Yaegashi Katsumi Shima Junji Suzuki Yuichi Saito akihiro nakata Takuya Nakazawa Tadanori Abe Masaki Yano Masanori Someya Kensei nakata Masakazu Hori Masato Hareyama Koichi Sakata 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2013年第1期1-5,共5页
Intensity modulated radiation therapy (IMRT) is a highly accurate technique that is usually implemented in either dynamic or step-and-shoot fashion with many segments each having low monitor units (MUs). The present s... Intensity modulated radiation therapy (IMRT) is a highly accurate technique that is usually implemented in either dynamic or step-and-shoot fashion with many segments each having low monitor units (MUs). The present study evaluated the effects of beam startup characteristics on the dose delivery accuracy for each segment at low MUs for step-and-shoot IMRT with an Elekta Precise accelerator at the highest dose rates. We used a two-dimensional semi-conductor detector for the dose measurements. The field size of each segment was assumed to be 20 ×20 cm2 and each segment was set to deliver 1 - 10 MUs. Our results show a variation in dose delivery accuracy between segments for the same IMRT beam, which can be attributed to the beam startup characteristics. This variability is attributed to the changes in the transient changes in the temperatures of the electron gun filament and the magnetron. That is, the transient increase in the temperature of the filament leads to increasing doses with time and that of the magnetron leads to decreasing doses with time during the first few MUs. 展开更多
关键词 Startup Performance Step-and-Shoot IMRT LOW MONITOR UNITS
下载PDF
The Reproducibility of Patient Setup for Head and Neck Cancers Treated with Image-Guided and Intensity-Modulated Radiation Therapies Using Thermoplastic Immobilization Device
2
作者 akihiro nakata Kunihiko Tateoka +5 位作者 Kazunori Fujimoto Yuichi Saito Takuya Nakazawa Tadanori Abe Masaki Yano Koichi Sakata 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2013年第4期117-124,共8页
The reproducibility of patient setup is an important issue for head and neck cancers treated with intensity-modulated radiation therapy (IMRT). In this study, an image-guided radiation therapy (IGRT) system has been u... The reproducibility of patient setup is an important issue for head and neck cancers treated with intensity-modulated radiation therapy (IMRT). In this study, an image-guided radiation therapy (IGRT) system has been used to minimize the uncertainty of patient setup while standard thermoplastic masks were used to provide adequate immobilization for the head and neck. However, they do not provide sufficient immobilization of the shoulders, which is an important requirement in comprehensive nodal irradiation. Therefore, we investigated the setup and rotational shifts in head and neck cancer patients undergoing IMRT for which this immobilization device had been used together with an IGRT system. The setup and rotational shifts of patients were analyzed using the ExacTrac X-ray 6D IGRT system. The patients were classified as having head and neck tumors in the upper or lower regions. The upper neck nodes included lymph nodal level II while the lower neck nodes included lymph nodal levels III and IV. Clinical data from 227 treatment sessions of 12 head and neck cancer patients were analyzed. The random translational error in inter-and intra-fraction errors of the anterio-posterior (AP) direction might influence the rotational errors of pitch and roll in the upper region. At the same time, the random translational error in the inter-and intra-fraction errors of the AP direction might influence the rotational error of roll in the lower region. We believe that these random translational errors should be considered during treatment. We found variability in random translational errors for different regions in the anatomy of head and neck cancer patients due to rotational shifts. Depending on the location of the primary lesion or the selected nodal treatment targets, these relative positional variations should be considered when setup and rotational shifts are corrected with IGRT systems before treatment. 展开更多
关键词 IMRT IGRT RADIATION Therapy IMMOBILIZATION Head and Neck Cancer