期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Size-specific dose estimates: Localizer or transverse abdominal computed tomography images? 被引量:1
1
作者 Sarvenaz Pourjabbar Sarabjeet Singh +3 位作者 Atul Padole akshay saini Michael A Blake Mannudeep K Kalra 《World Journal of Radiology》 CAS 2014年第5期210-217,共8页
AIM: To investigate effect of body dimensions obtained from localizer radiograph and transverse abdominal computed tomography(CT) images on Size Specific Dose Estimate. METHODS: This study was approved by Institutiona... AIM: To investigate effect of body dimensions obtained from localizer radiograph and transverse abdominal computed tomography(CT) images on Size Specific Dose Estimate. METHODS: This study was approved by Institutional Review Board and was compliant with Health Insurance Portability and Accountability Act. Fifty patients with abdominal CT examinations(58 ± 13 years, Male: Female 28:22) were included in this study. Anteriorposterior(AP) and lateral(Lat) diameters were measured at 5 cm intervals from the CT exam localizer radiograph(simple X-ray image acquired for planning the CT exam before starting the scan) and transverse CT images. Average of measured AP and Lat diameters, as well as maximum, minimum and mid location AP and Lat were measured on both image sets. In addition, off centering of patients from the gantry iso-center was calculated from the localizers. Conversion factors from American Association of Physicists in Medicine(AAPM) report 204 were obtained for AP, Lat, AP + Lat, and effective diameter(√ AP * Lat) to determine size specificdose estimate(SSDE) from the CT dose index volume(CTDIvol) recorded from the dose reports. Data were analyzed using SPSS v19. RESULTS: Total number of 5376 measurements was done. In some patients entire body circumference was not covered on either projection radiograph or transverse CT images; hence accurate measurement of AP and Lat diameters was not possible in 11%(278/2488) of locations. Forty one patients were off-centered with mean of 1.9 ± 1.8 cm(range: 0.4-7 cm). Conversion factors for attained diameters were not listed on AAPM look-up tables in 3%(80/2488) of measurements. SSDE values were significantly different compared to CTDIvol, ranging from 32% lower to 74% greater than CTDIvol. CONCLUSION: There is underestimation and overestimation of dose comparing SSDE values to CTDIvol. Localizer radiographs are associated with overestimation of patient size and therefore underestimation of SSDE. 展开更多
关键词 SIZE SPECIFIC DOSE estimate Computed tomography DOSE index RADIATION DOSE reduction RADIATION DOSE optimization
下载PDF
CFOA Based Low Pass and High Pass Ladder Filter—A New Configuration 被引量:1
2
作者 Praween K. Sinha akshay saini +1 位作者 Pranav Kumar Sumit Mishra 《Circuits and Systems》 2014年第12期293-300,共8页
A new technique using signal flow graph for conversion of ladder based filter into CFOA based filter has been proposed. The proposed technique converts the existing LC ladder based filter into CFOA in low pass and hig... A new technique using signal flow graph for conversion of ladder based filter into CFOA based filter has been proposed. The proposed technique converts the existing LC ladder based filter into CFOA in low pass and high pass configuration. The design of low pass filter and high pass filter has been realized using the proposed technique. The proposed configuration is implemented using CFOA as an active device and all the capacitors are grounded. Simulation has been carried out using simulation software I-cap. The simulation results have been demonstrated and discussed. 展开更多
关键词 CFOA-Current Feedback Operational Amplifier LADDER FILTER Signal Flow Graph Current MODE Voltage MODE HIGH PASS FILTER Low PASS FILTER
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部