The authors show the results of a study conducted on a joint connecting a concrete column to a composite steel concrete floor,subjected to tension on the beams as a result of the decomposition of sagging bending momen...The authors show the results of a study conducted on a joint connecting a concrete column to a composite steel concrete floor,subjected to tension on the beams as a result of the decomposition of sagging bending moment.The beam to column connection is achieved by means of headed studs welded to the beam and embedded in the concrete cast.Five different configurations have been tested at failure and the results are compared to formulae proposed in literature.Different degrees of ductility,reliability and strength have been obtained varying geometry and reinforcement ratio on the joints tested.展开更多
文摘The authors show the results of a study conducted on a joint connecting a concrete column to a composite steel concrete floor,subjected to tension on the beams as a result of the decomposition of sagging bending moment.The beam to column connection is achieved by means of headed studs welded to the beam and embedded in the concrete cast.Five different configurations have been tested at failure and the results are compared to formulae proposed in literature.Different degrees of ductility,reliability and strength have been obtained varying geometry and reinforcement ratio on the joints tested.