Pedicle screw accuracy assessment in ExcelsiusGPS?robotic spine surgery:evaluation of deviation from pre-planned trajectory 被引量:3
1
作者 Bowen Jiang A.Karim Ahmed +8 位作者 Corinna C.Zygourakis Samuel Kalb alex m.zhu Jakub Godzik Camilo A.Molina Ari M.Blitz Ali Bydon Neil Crawford Nicholas Theodore 《Chinese Neurosurgical Journal》 CSCD 2018年第3期118-123,共6页
Background: The ExcelsiusGPS?(Globus Medical, Inc., Audubon, PA) is a next-generation spine surgery robotic system recently approved for use in the United States. The objective of the current study is to assess pedicl... Background: The ExcelsiusGPS?(Globus Medical, Inc., Audubon, PA) is a next-generation spine surgery robotic system recently approved for use in the United States. The objective of the current study is to assess pedicle screw accuracy and clinical outcomes among two of the first operative cases utilizing the ExcelsiusGPS?robotic system and describe a novel metric to quantify screw deviation. Methods: Two patients who underwent lumbar fusion at a single institution with the ExcelsiusGPS?surgical robot were included. Pre-operative trajectory planning was performed from an intra-operative CT scan using the O-arm (Medtronic, Inc., Minneapolis, MN). After robotic-assisted screw implantation, a post-operative CT scan was obtained to confirm ideal screw placement and accuracy with the planned trajectory. A novel pedicle screw accuracy algorithm was devised to measure screw tip/tail deviation distance and angular offset on axial and sagittal planes. Screw accuracy was concurrently determined by a blinded neuroradiologist using the traditional Gertzbein-Robbins method. Clinical variables such as symptomatology, operative data, and post-operative follow-up were also collected. Results: Eight pedicle screws were placed in two L4-L5 fusion cases. Mean screw tip deviation was 2.1 mm (range 0.8-5.2 mm), mean tail deviation was 3.2 mm (range 0.9-5.4 mm), and mean angular offset was 2.4 degrees (range 0.7-3.8 degrees). All eight screws were accurately placed based on the Gertzbein-Robbins scale (88% Grade A and 12% Grade B). There were no cases of screw revision or new post-operative deficit. Both patients experienced improvement in Frankel grade and Karnofsky Performance Status (KPS) score by 6 weeks post-op. Conclusion: The ExcelsiusGPS? robot allows for precise execution of an intended pre-planned trajectory and accurate screw placement in the first patients to undergo robotic-assisted fusion with this technology. 展开更多
关键词 Robotic spine surgery Robot-assisted surgery Excelsius GPS® Gertzbein-Robbins Pedicle screw accuracy
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部