期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Experimental characterization of the removal efficiency and energy effectiveness of central air cleaners
1
作者 Patrice Blondeau Marc Olivier Abadie +6 位作者 alexandra durand Pascal Kaluzny Sylvie Parat Alain Ginestet Dominique Pugnet Céline Tourreilles Thierry Duforestel 《Energy and Built Environment》 2021年第1期1-12,共12页
This study assessed six commercially available in-duct air cleaning devices which are designed to be mounted in the central ventilation system of offices or commercial buildings.The selected devices use different air ... This study assessed six commercially available in-duct air cleaning devices which are designed to be mounted in the central ventilation system of offices or commercial buildings.The selected devices use different air cleaning technologies:mechanical filtration,electrostatic precipitation,gas filtration,ionization/cold plasma,photocatalytic oxidation(PCO)and catalysis under UV light.They were tested against particles,a mixture of volatile organic compounds containing acetone,acetaldehyde,toluene,heptane and formaldehyde,and two bio-contaminants:Aspergillus brasiliensis(fungus)and Staphylococcus epidermidis(bacteria).Two different test rigs were used.The single pass efficiency of each device was determined for three airflow rates,corresponding to face velocities ranging from 0.9 to 2.7 m/s,and two sets of temperature and humidity that are representative of indoor air conditions in wintertime and summertime.The concentration of the chal-lenge volatile organic compounds was also varied in the 30 to 100μg/m^(3)range as a way to characterize their influence on efficiency at realistic concentration levels for non-industrial buildings.Measurements of ozone and formaldehyde concentration downstream of the air cleaners were carried out to determine the emission rate of by-products into the air stream.Finally,the energy issue was addressed by measuring the electric power drawn and pressure loss of the devices.The results showed that two devices,namely a radiant catalytic ionizer and a plasma ionizer,had a very low single pass efficiency against all the challenge pollutants.The association of the plasma ionizer and the electrostatic precipitator did not produce a synergetic effect between the two technologies either,contrary to what their manufacturer claims.Finally,three of the six devices tested were effective in terms of pollutant removal,but only two had an acceptable energy effectiveness in view of their use in low or zero energy buildings.Their energy effectiveness ranged from a few thousand m^(3)/kWh for VOCs at the highest airflow rate(3600 m^(3)/h),to more than 60000 m^(3)/kWh for particles and bio-contaminants at 1200 or 1600 m^(3)/h.These results are at least one order of magnitude higher than the majority of stand-alone air cleaners.Moreover,they suggest that optimal IAQ and energy conditions can be achieved if variable air volume control methods are used to maintain indoor temperature and humidity. 展开更多
关键词 Central air cleaners EFFICIENCY Clean air delivery rate Energy effectiveness By-products OZONE
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部