The thermal-hydraulic performance of plain tubes with and without wire coils in turbulent regimes is investigated experimentally and numerically.The effects of wire coil distribution(circular cross section)within the ...The thermal-hydraulic performance of plain tubes with and without wire coils in turbulent regimes is investigated experimentally and numerically.The effects of wire coil distribution(circular cross section)within the tube were explored experimentally,and water was employed as the working fluid.The numerical simulation was carried out using software programmer ANSYS Fluent 2019 R3 using the finite-volume approach.In the turbulent regime,six cross-sectionedwire coilswere analyzed,including:circular,rectangular,hexagonal,square,star shape,and triangle.The utilization of a tube with a wire coil has been shown to increase heat transfer rate and pump consumption.The results indicate a high level of concurrence,as the deviations are all below 8%.Compared with plain tube,the wire coils,according to the arrangement(TWD),gave the best PEC.The heat transfer enhancement ability of different cross sections follows the following order:StCS>RCS>HCS>SqCS>CCS>TCS.Also,the sequence of pump consumption for each cross section is as follows:RCS>StCS>SqCS>HCS>CCS>TCS.展开更多
文摘The thermal-hydraulic performance of plain tubes with and without wire coils in turbulent regimes is investigated experimentally and numerically.The effects of wire coil distribution(circular cross section)within the tube were explored experimentally,and water was employed as the working fluid.The numerical simulation was carried out using software programmer ANSYS Fluent 2019 R3 using the finite-volume approach.In the turbulent regime,six cross-sectionedwire coilswere analyzed,including:circular,rectangular,hexagonal,square,star shape,and triangle.The utilization of a tube with a wire coil has been shown to increase heat transfer rate and pump consumption.The results indicate a high level of concurrence,as the deviations are all below 8%.Compared with plain tube,the wire coils,according to the arrangement(TWD),gave the best PEC.The heat transfer enhancement ability of different cross sections follows the following order:StCS>RCS>HCS>SqCS>CCS>TCS.Also,the sequence of pump consumption for each cross section is as follows:RCS>StCS>SqCS>HCS>CCS>TCS.