期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Effect of varying computed tomography acquisition and reconstruction parameters on semi-automated clot volume quantification 被引量:3
1
作者 Audrey E Kaufman alison n pruzan +4 位作者 Ching Hsu Sarayu Ramachandran Adam Jacobi Zahi A Fayad Venkatesh Mani 《World Journal of Radiology》 CAS 2018年第3期24-29,共6页
AIM To examine effects of computed tomography(CT)image acquisition/reconstruction parameters on clot volume quantification in vitro for research method validation purposes.METHODS This study was performed in conforman... AIM To examine effects of computed tomography(CT)image acquisition/reconstruction parameters on clot volume quantification in vitro for research method validation purposes.METHODS This study was performed in conformance with HIPAA and IRB Regulations(March 2015-November 2016).A ten blood clot phantom was designed and scanned on a dual-energy CT scanner(SOMATOM Force,Siemens Healthcare Gm BH,Erlangen,Germany)with varying pitch,iterative reconstruction,energy level and slicethickness.A range of clot and tube sizes were used in an attempt to replicate in vivo emboli found within central and segmental branches of the pulmonary arteries in patients with pulmonary emboli.Clot volume was the measured parameter and was analyzed by a single image analyst using a semi-automated region growing algorithm implemented in the FDA-approved Siemens syngo.via image analysis platform.Mixed model analysis was performed on the data.RESULTS On the acquisition side,the continuous factor of energy showed no statistically significant effect on absolute clot volume quantification(P=0.9898).On the other hand,when considering the fixed factor of pitch,there were statistically significant differences in clot volume quantification(P<0.0001).On the reconstruction side,with the continuous factor of reconstruction slice thickness no statistically significant effect on absolute clot volume quantification was demonstrated(P=0.4500).Also on the reconstruction side,with the fixed factor of using iterative reconstructions there was also no statistically significant effect on absolute clot volume quantification(P=0.3011).In addition,there was excellent R^2 correlation between the scale-measured mass of the clots both with respect to the CT measured volumes and with respect to volumes measure by the water displacement method.CONCLUSION Aside from varying pitch,changing CT acquisition parameters and using iterative reconstructions had no significant impact on clot volume quantification with a semi-automated region growing algorithm. 展开更多
关键词 Computed tomography ANGIOGRAPHY RADIOGRAPHIC phantom COMPUTER-ASSISTED image analysis Pulmonary EMBOLISM THROMBOLYTIC therapy
下载PDF
Reproducibility of thrombus volume quantification in multicenter computed tomography pulmonary angiography studies 被引量:3
2
作者 Audrey E Kaufman alison n pruzan +7 位作者 Ching Hsu Sarayu Ramachandran Adam Jacobi Indravadan Patel Lee Schwocho Michele F Mercuri Zahi A Fayad Venkatesh Mani 《World Journal of Radiology》 CAS 2018年第10期124-134,共11页
AIM To evaluate reproducibility of pulmonary embolism(PE) clot volume quantification using computed tomography pulmonary angiogram(CTPA) in a multicenter setting.METHODS This study was performed using anonymized data ... AIM To evaluate reproducibility of pulmonary embolism(PE) clot volume quantification using computed tomography pulmonary angiogram(CTPA) in a multicenter setting.METHODS This study was performed using anonymized data in conformance with HIPAA and IRB Regulations(March 2015-November 2016). Anonymized CTPA data was acquired from 23 scanners from 18 imaging centers using each site's standard PE protocol. Two independent analysts measured PE volumes using a semi-automated region-growing algorithm on an FDA-approved image analysis platform. Total thrombus volume(TTV) was calculated per patient as the primary endpoint. Secondary endpoints were individual thrombus volume(ITV), Qanadli score and modified Qanadli score per patient. Inter-and intra-observer reproducibility were assessed using intra-class correlation coefficient(ICC) and BlandAltman analysis. RESULTS Analyst 1 found 72 emboli in the 23 patients with a mean number of emboli of 3.13 per patient with a range of 0-11 emboli per patient. The clot volumes ranged from 0.0041-47.34 cm3(mean +/-SD, 5.93 +/-10.15 cm3). On the second read, analyst 1 found the same number and distribution of emboli with a range of volumes for read 2 from 0.0041 – 45.52 cm3(mean +/-SD, 5.42 +/-9.53 cm3). Analyst 2 found 73 emboli in the 23 patients with a mean number of emboli of 3.17 per patient with a range of 0-11 emboli per patient. The clot volumes ranged from 0.00459-46.29 cm3(mean +/-SD, 5.91 +/-10.06 cm3). Inter-and intraobserver variability measurements indicated excellent reproducibility of the semi-automated method for quantifying PE volume burden. ICC for all endpoints was greater than 0.95 for inter-and intra-observer analysis. Bland-Altman analysis indicated no significant biases.CONCLUSION Semi-automated region growing algorithm for quantifying PE is reproducible using data from multiple scanners and is a suitable method for image analysis in multicenter clinical trials. 展开更多
关键词 Pulmonary EMBOLISM ARTERIES Computed tomography angiography COMPUTER-ASSISTED image analysis THROMBOLYTIC therapy
下载PDF
Feasibility of imaging superficial palmar arch using microultrasound,7T and 3T magnetic resonance imaging
3
作者 alison n pruzan Audrey E Kaufman +3 位作者 Claudia Calcagno Yu Zhou Zahi A Fayad Venkatesh Mani 《World Journal of Radiology》 CAS 2017年第2期79-84,共6页
AIM To demonstrate feasibility of vessel wall imaging of the superficial palmar arch using high frequency microultrasound, 7T and 3T magnetic resonance imaging(MRI).METHODS Four subjects(ages 22-50 years) were scanned... AIM To demonstrate feasibility of vessel wall imaging of the superficial palmar arch using high frequency microultrasound, 7T and 3T magnetic resonance imaging(MRI).METHODS Four subjects(ages 22-50 years) were scanned on a micro-ultrasound system with a 45-MHz transducer(Vevo 2100, Visual Sonics). Subjects' hands were then imaged on a 3T clinical MR scanner(Siemens Biograph MMR) using an 8-channel special purpose phased array carotid coil. Lastly, subjects' hands were imaged on a 7T clinical MR scanner(Siemens Magnetom 7T Whole Body Scanner) using a custom built 8-channel transmit receive carotid coil. All three imaging modalities were subjectively analyzed for image quality and visualization of the vessel wall. RESULTS Results of this very preliminary study indicated that vessel wall imaging of the superficial palmar arch was feasible with a whole body 7T and 3T MRI in comparison with micro-ultrasound. Subjective analysis of image quality(1-5 scale, 1: poorest, 5: best) from B mode, ultrasound, 3T SPACE MRI and 7T SPACE MRI indicated that the image quality obtained at 7T was superior to both 3T MRI and micro-ultrasound. The 3D SPACE sequence at both 7T and 3T MRI with isotropic voxels allowed for multi-planarreformatting of images and allowed for less operator dependent results as compared to high frequency microultrasound imaging. Although quantitative analysis revealed that there was no significant difference between the three methods, the 7T Tesla trended to have better visibility of the vessel and its wall. CONCLUSION Imaging of smaller arteries at the 7T is feasible for evaluating atherosclerosis burden and may be of clinical relevance in multiple diseases. 展开更多
关键词 表面的手掌的拱门 7T 3T 磁性的回声成像 微超声 动脉粥样硬化 心血管的疾病
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部