Investigation of Bandwidth Requirement of Smart Meter Network Using OPNET Modeler 被引量:1
1
作者 M. Rahman amanullah mto 《Smart Grid and Renewable Energy》 2013年第4期378-390,共13页
Smart meter networks are the backbone for smart electrical distribution grid. Smart meter network requires the bidirectional communications medium and interoperability capability. As thousands of meters are interconne... Smart meter networks are the backbone for smart electrical distribution grid. Smart meter network requires the bidirectional communications medium and interoperability capability. As thousands of meters are interconnected in the smart meter network, it is vital to select an appropriate communication bandwidth to facilitate real-time two-way information flows and this will also allow further uptake of greenhouse-friendly technology options and enhance energy security. Optimized Network Engineering Tools (OPNET) Modeler is one of most powerful simulation tools for the analysis of communication networks. In this paper, several models of different structured smart meter networks were developed with network parameters which were connected with different communication links such as 10 BaseT and 100 BaseT in order to measure propagation delay, throughput, and utilization of the network. It was found that the propagation delay decreases with higher bandwidth. The other network parameters, namely network utilization and network throughput were also analysed. Based on the investigation, it is recommended that the 100 BaseT communication link is suitable for the smart meter network. The outcome of this paper provided a guideline to the future smart meter network developer so as to avoid catastrophic challenges faced by some of the distribution companies. 展开更多
关键词 SMART METER NETWORK SMART METER ROUTER FIREWALL Server Communication Bandwidth Propagation Delay Throughput Utilization
下载PDF
Automatic Generation Control of Multigeneration Power System
2
作者 Asma Aziz amanullah mto Alex Stojsevski 《Journal of Power and Energy Engineering》 2014年第4期312-333,共22页
Load frequency Control (LFC) is used for many years as part of Automatic Generation Control (AGC) in power system around the world. In a mixed power system, it is usual to find an area regulated by hydro generation in... Load frequency Control (LFC) is used for many years as part of Automatic Generation Control (AGC) in power system around the world. In a mixed power system, it is usual to find an area regulated by hydro generation interconnected to another area regulated by thermal generation or in combination of both. In the following study, performance of AGC for Thermal, Hydro and Thermal turbine based power system is examined, including how frequency bias setting influences AGC response and inadvertent interchange. Control performance analysis of three area interconnected systems is simulated and studied through Matlab Simulink software. Integral square error and Integral time absolute error has been used as performance criterion. It is shown that integral time absolute error (ITAE) as performance index leads to faster optimization of controller gain. 展开更多
关键词 Automatic Generation Control Performance INDEX ISE ITAE DISCRETE CONTROLLER