The objective of this work is to analyze and evaluate the impact of cooling systems on photovoltaic modules (for electricity generation), applied at a pilot Testing Facility. The results obtained during this step are ...The objective of this work is to analyze and evaluate the impact of cooling systems on photovoltaic modules (for electricity generation), applied at a pilot Testing Facility. The results obtained during this step are used as input in order to determine the best model to be applied at a real-scale Photovoltaic Power Plant (PVPP). This methodology is based on the monitoring and supervision of the operating temperature of commercial photovoltaic modules (PV), both with and without cooling systems, as well as on the study of the water supply design of the cooling system applied on a micro photovoltaic power plant which is connected to the commercial network. Through the analysis of the data, we observed that photovoltaic modules with cooling systems always operate at lower temperatures than the ones without cooling systems. During the testing period, the operating temperatures of the photovoltaic modules without cooling systems were above 60oC (with a maximum temperature equaling 68.06oC), whereas the maximum temperatures registered on the sensors of the model “A” were 43.55oC and 44.75oC, and the ones registered on the sensors of the model “B” were 46.76 and 48.33oC. Therefore, we conclude that the photovoltaic module with the cooling system model “A” is the most suitable for large-scale application, since it was the only model to present temperatures lower than the nominal operating condition temperature (NOCT) of the cell (47oC ± 2oC).展开更多
This paper aims to assess the Initial Investment Valuation Methodology of the local regulator, facing the results of auctions, due to the high occurrence of low clearing prices observed from 2003 to 2008 and the high ...This paper aims to assess the Initial Investment Valuation Methodology of the local regulator, facing the results of auctions, due to the high occurrence of low clearing prices observed from 2003 to 2008 and the high percentage of auctions without any bidder recently. The regulator investment forecasted defines the maximum value of Yearly Allowed Revenue and the bidder that offers the lowest YAR value wins the auction. The first type of analysis considers project cost, location, execution deadline, transmission line extension and type of all actions from 1999 to 2015, totalling about 3.361 billion USD. It was not found any correlation of those variables and the result of the actions. The second analysis compared the equipment and the additional costs breakdown of the regulator investment forecast with the real investment in projects from 2009 to 2013 and it rarely surpasses 5%. Suggestions are proposed based on the analysis.展开更多
文摘The objective of this work is to analyze and evaluate the impact of cooling systems on photovoltaic modules (for electricity generation), applied at a pilot Testing Facility. The results obtained during this step are used as input in order to determine the best model to be applied at a real-scale Photovoltaic Power Plant (PVPP). This methodology is based on the monitoring and supervision of the operating temperature of commercial photovoltaic modules (PV), both with and without cooling systems, as well as on the study of the water supply design of the cooling system applied on a micro photovoltaic power plant which is connected to the commercial network. Through the analysis of the data, we observed that photovoltaic modules with cooling systems always operate at lower temperatures than the ones without cooling systems. During the testing period, the operating temperatures of the photovoltaic modules without cooling systems were above 60oC (with a maximum temperature equaling 68.06oC), whereas the maximum temperatures registered on the sensors of the model “A” were 43.55oC and 44.75oC, and the ones registered on the sensors of the model “B” were 46.76 and 48.33oC. Therefore, we conclude that the photovoltaic module with the cooling system model “A” is the most suitable for large-scale application, since it was the only model to present temperatures lower than the nominal operating condition temperature (NOCT) of the cell (47oC ± 2oC).
文摘This paper aims to assess the Initial Investment Valuation Methodology of the local regulator, facing the results of auctions, due to the high occurrence of low clearing prices observed from 2003 to 2008 and the high percentage of auctions without any bidder recently. The regulator investment forecasted defines the maximum value of Yearly Allowed Revenue and the bidder that offers the lowest YAR value wins the auction. The first type of analysis considers project cost, location, execution deadline, transmission line extension and type of all actions from 1999 to 2015, totalling about 3.361 billion USD. It was not found any correlation of those variables and the result of the actions. The second analysis compared the equipment and the additional costs breakdown of the regulator investment forecast with the real investment in projects from 2009 to 2013 and it rarely surpasses 5%. Suggestions are proposed based on the analysis.