期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Evaluation of Myocardial Performance in Hypertensive Patients with Type 2 Diabetes and Normal Ejection Fraction
1
作者 Muataz F. Hussein Samar I. Essa anmar z. saleh 《Health》 2015年第12期1721-1724,共4页
Diabetes (DM) and hypertension (HT) cause changes in cardiac performance. Long-term diabetes and hypertension can lead to changes in cardiac contractility, reduced left ventricular efficiency and heart failure. The ai... Diabetes (DM) and hypertension (HT) cause changes in cardiac performance. Long-term diabetes and hypertension can lead to changes in cardiac contractility, reduced left ventricular efficiency and heart failure. The aim of this study is to evaluate the effect of the coexistence of diabetes mellitus and hypertension on left ventricular myocardial performance and structural changes. The study involved 45 patients with essential hypertension and type 2 diabetes (14 males and 31 females, their mean age was 53.28 ± 13.28 years), and 45 healthy subjects (10 males and 35 females, their mean age was 48.11 ± 13.07 years) as a control group. Transthoracic echocardiography was done for all patients. The echocardiographic measurements included: left ventricle internal diameter at end diastole (LVIDd), left ventricle internal diameter at end systole (LVIDs), peak velocity of early transmitral flow (E), peak velocity of late transmitral flow (A), ejection fraction (EF%), isovolumic relaxation time (IVRT), isovolumic contraction time (IVCT) and ejection time (ET) from which the index of myocardial performance (IMP) was calculated. Results revealed a significant change in the ratio (E/A) between patients and controls (-32.45%) with p value p value 0.05. In conclusion, diabetic patients with hypertension had an increase in IMP and reduced E/A indicating deterioration in cardiac performance despite normal ejection fraction and insignificant change in LV dimensions. 展开更多
关键词 DIABETES and HYPERTENSION ECHOCARDIOGRAPHY Index of MYOCARDIAL Performance
下载PDF
Evaluation of Effectiveness of Diode Laser System (808 nm) versus Intense Pulse Light (IPL) in the Management of Unwanted Hair: A Split Face Comparative Study
2
作者 Hayder R. AL-Hamamy anmar z. saleh zahra A. Rashed 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2015年第1期41-48,共8页
We have evaluated and compared the effectiveness of diode laser system (808 nm) and Intense Pulse Light (IPL) system (690 - 1200 nm) by studying the change in hair density, and the time of regrowth the hair. A total o... We have evaluated and compared the effectiveness of diode laser system (808 nm) and Intense Pulse Light (IPL) system (690 - 1200 nm) by studying the change in hair density, and the time of regrowth the hair. A total of 26 have completed three months’ treatment, aged 16 - 50 years. Patients were treated by diode laser 808 nm and IPL 690 - 1200 nm devices. Pulse repetition rate for both was 1 Hz and short pulse width for diode laser and the IPL pulse width was 15 ms. The fluence was (33 - 41 and 30 - 41) J/cm2 respectively. A split face treatment method was used. The treatment was carried out on monthly bases for three months. Hair density and regrowth duration were recorded before and after each session. After the third session, the hair density was decreased by (58%) for diode laser versus (49%) for IPL p = 0.366. The time of hair regrowth was increased to (327%) for diode laser versus IPL (339%) p = 0.821. Pain appeared more during the treatment with IPL than with diode laser. Post treatment side effects such as erythema, hyper pigmentation, and burn appeared on patients treated with diode laser more than those treated with IPL. In conclusion both diode laser and IPL were effective in reduction of hair density, and prolongation of the time of hair regrowth. 展开更多
关键词 Unwanted FACIAL HAIR DIODE Laser IPL
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部