The simultaneous determination of cobalt, copper and nickel using 1-(2-thiazolylazo)-2-naphthol (first figure of this article) by spectrophotometric method is a difficult problem in analytical chemistry, due to sp...The simultaneous determination of cobalt, copper and nickel using 1-(2-thiazolylazo)-2-naphthol (first figure of this article) by spectrophotometric method is a difficult problem in analytical chemistry, due to spectral interferences. By multivariate calibration methods, such as partial least squares (PLS) regression, it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Orthogonal signal correction (OSC) is a preprocessing technique used for removing the information unrelated to the target variables based on constrained principal component analysis. OSC is a suitable preprocessing method for PLS calibration of mixtures without loss of prediction capacity using spectrophotometric method. In this study, the calibration model is based on absorption spectra in the 550-750-nm range for 21 different mixtures of cobalt, copper and nickel. Calibration matrices were formed from samples containing 0.05-1.05, 0.05-1.30 and 0.05-0.80 μg·mL^-1 for cobalt, copper and nickel, respectively. The root mean square error of prediction (RMSEP) for cobalt, copper and nickel with OSC and without OSC were 0.007, 0.008, 0.011 and 0.031,0.037, 0.032 μg· mL^-1, respectively. This procedure allows the simultaneous determination of cobalt, copper and nickel in synthetic and real samples and good reliability of the determination was proved.展开更多
New adsorptive anodic differential pulse stripping voltammetry method for the direct determination of morphine at trace levels in human plasma of addicts is proposed.The procedure involves an adsorptive accumulation o...New adsorptive anodic differential pulse stripping voltammetry method for the direct determination of morphine at trace levels in human plasma of addicts is proposed.The procedure involves an adsorptive accumulation of morphine on a HMDE,followed by oxidation of adsorbed morphine by voltammetry scan using differential pulse modulation.The optimum conditions for the analysis of morphine are pH 10.5,Eacc of -100 mV(vs.Ag/AgCl),and tacc of 120 s.The peak current is proportional to the concentration of morphine,and a Linear calibration graph is obtained at 0.01-3.10μg mL^-1.A relative standard deviation of 1.06%(n=5)was obtained,and the limit of detection was 3 ng mL^-1.The capabiLity of the method for the analysis of real samples was evaluated by the determination of morphine in spiked human plasma and addicts human plasma with satisfactory results.展开更多
The acid-base properties of 1-(2-thiazolylazo)-2-naphthol (TAN) in mixtures of methanol-water at 25℃ and an ionic strength of 0.1 mol/L are studied by a multi-wavelength spectrophotometfic method. The acidity con...The acid-base properties of 1-(2-thiazolylazo)-2-naphthol (TAN) in mixtures of methanol-water at 25℃ and an ionic strength of 0.1 mol/L are studied by a multi-wavelength spectrophotometfic method. The acidity constants of all related equilibria are estimated using the whole spectral fitting of the collected data to an established factor analysis model. DATAN program was used for determination of acidity constants. The corresponding pKa values in methanol-water mixtures were determined. There is a linear relationship between acidity constants and the mole fraction of methanol in the solvent mixtures.展开更多
文摘The simultaneous determination of cobalt, copper and nickel using 1-(2-thiazolylazo)-2-naphthol (first figure of this article) by spectrophotometric method is a difficult problem in analytical chemistry, due to spectral interferences. By multivariate calibration methods, such as partial least squares (PLS) regression, it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Orthogonal signal correction (OSC) is a preprocessing technique used for removing the information unrelated to the target variables based on constrained principal component analysis. OSC is a suitable preprocessing method for PLS calibration of mixtures without loss of prediction capacity using spectrophotometric method. In this study, the calibration model is based on absorption spectra in the 550-750-nm range for 21 different mixtures of cobalt, copper and nickel. Calibration matrices were formed from samples containing 0.05-1.05, 0.05-1.30 and 0.05-0.80 μg·mL^-1 for cobalt, copper and nickel, respectively. The root mean square error of prediction (RMSEP) for cobalt, copper and nickel with OSC and without OSC were 0.007, 0.008, 0.011 and 0.031,0.037, 0.032 μg· mL^-1, respectively. This procedure allows the simultaneous determination of cobalt, copper and nickel in synthetic and real samples and good reliability of the determination was proved.
文摘New adsorptive anodic differential pulse stripping voltammetry method for the direct determination of morphine at trace levels in human plasma of addicts is proposed.The procedure involves an adsorptive accumulation of morphine on a HMDE,followed by oxidation of adsorbed morphine by voltammetry scan using differential pulse modulation.The optimum conditions for the analysis of morphine are pH 10.5,Eacc of -100 mV(vs.Ag/AgCl),and tacc of 120 s.The peak current is proportional to the concentration of morphine,and a Linear calibration graph is obtained at 0.01-3.10μg mL^-1.A relative standard deviation of 1.06%(n=5)was obtained,and the limit of detection was 3 ng mL^-1.The capabiLity of the method for the analysis of real samples was evaluated by the determination of morphine in spiked human plasma and addicts human plasma with satisfactory results.
文摘The acid-base properties of 1-(2-thiazolylazo)-2-naphthol (TAN) in mixtures of methanol-water at 25℃ and an ionic strength of 0.1 mol/L are studied by a multi-wavelength spectrophotometfic method. The acidity constants of all related equilibria are estimated using the whole spectral fitting of the collected data to an established factor analysis model. DATAN program was used for determination of acidity constants. The corresponding pKa values in methanol-water mixtures were determined. There is a linear relationship between acidity constants and the mole fraction of methanol in the solvent mixtures.